background image

EG9936    Revised 01/22

CAUTION 

INSPECT CONTENTS IMMEDIATELY AND FILE CLAIM WITH DELIVERING CARRIER FOR ANY DAMAGE. 

SAVE YOUR BOX AND ALL PACKING MATERIALS. 

YOU ARE RESPONSIBLE FOR DAMAGE TO YOUR UNIT IF RETURNED IMPROPERLY PACKED. 

(continued on next page)

! ! ! ! ! ! ! !

Model: CLGF30-LP

FOR YOUR SAFETY:

 Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other 

appliance.  

MESURE DE SÉCURITÉ:

 Ne pas entreposer ni utiliser d’essence ni autres vapeurs ou liquides inflammables à proximité de cet 

appareil ou de tout autre appareil. 

IMPORTANT FOR FUTURE REFERENCE 

Please complete this information and retain this manual for the life of the equipment. For Warranty Service and/or parts, this information is required.  

 

 

 

Model Number

Serial Number

Date Purchased 

CLGF30-LP

WARNING:

 Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. 

Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. 

AVERTISSEMENT:

 L’installation, le réglage, la modification, la réparation ou l’entretien incorrects de cet appareil peuvent 

causer des dommages matériels, des blessures ou la mort. Lire attentivement les instructions d’installation, de fonctionnement 

et d’entretien avant de procéder à son installation ou entretien.

WARNING:

 Instructions must be posted in a prominent location. All safety precautions must be taken in the event the user smells 

gas. Safety information can be obtained from your local gas supplier. 

AVERTISSEMENT:

 Les instructions doivent être a

ff

ichées dans un endroit très visible. Toutes les mesures de sécurité doivent 

être prises au cas où l'utilisateur sente l'odeur de gaz. L'information de sécurité peut être obtenue de votre fournisseur local de 

gaz. 

CAUTION:

 These models are designed, built, and sold for commercial use only. If these models are positioned so the general 

public can use the equipment, make sure that cautions, warnings, and operating instructions are clearly posted near each unit 

so that anyone using the equipment will use it correctly and not injure themselves or harm the equipment. 

ATTENTION:

 Ces modèles sont conçus, fabriqués, et vendus pour un usage commercial seulement. Si ces modèles sont placés 

pour que le grand public puisse les utiliser, assurez-vous que les consignes d’attention, d'avertissement, et les instructions 

d'utilisation soient clairement a

ff

ichées près de chaque unité de sorte que n'importe quel utilisateur de l'appareil l'emploie 

correctement et ne se blesse pas ou n'endommage pas l'appareil. 

INSTALLATION OPERATING & MAINTENANCE INSTRUCTIONS

Gas Fryer (LPG Unit)

INSTRUCTION  

SHEET  

#383291

Eagle Foodservice Equipment, Eagle MHC, and SpecFAB

®

 are divisions of Eagle Group. ©2022 by the Eagle Group

• 100 Industrial Boulevard, Clayton, Delaware 19938-8903 U.S.A.  
• Phone: 302/653-3000 • 800/441-8440  
• Fax: 302/653-2065 • www.eaglegrp.com 

Summary of Contents for CLGF30-LP

Page 1: ...structions must be posted in a prominent location All safety precautions must be taken in the event the user smells gas Safety information can be obtained from your local gas supplier AVERTISSEMENT Le...

Page 2: ...d arr t manuel pendant tout test de pression du syst me de canalisation de gaz pression de test gale ou inf rieure psi 3 45 kPa TABLE OF CONTENTS ITEM PAGE Safety precautions 3 General Installation In...

Page 3: ...ctice which could result in serious injury or death AVERTISSEMENT Ce symbole d signe un possible danger ou une pratique dangereuse qui pourrait entra ner des blessures graves ou la mort CAUTION This s...

Page 4: ...CLOSE PROXIMITY TO THIS APPLIANCE Combustible clearances 6 sides 152mm 6 rear 152mm 4 floor 102mm Non combustible clearances 0 sides 0mm 0 rear 0mm 4 floor 102mm Do not obstruct the flow of combustio...

Page 5: ...ep 1 Ensure this Gas Control Valve dial is at the OFF position LIGHTIING INSTRUCTIONS Fryers are furnished with a Gas Control Safety Valve Please follow the instructions below Before Lighting Pilot an...

Page 6: ...sides or back Avoid wall type fans which create air cross currents within a room It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air remov...

Page 7: ...e a week 4 Strain the frying compound into a clean container Make sure there is no compound left in tank If the tank is left empty for more than 2 minutes shut the pilot off If this is not done the ta...

Page 8: ...quefy Add to adjust compound level 3 Use a quality frying compound 4 Filter the frying compound frequently at least once a day 5 Skim out food particles frequently with a strainer skimmer 6 Add at lea...

Page 9: ...1 1 1 1 1 1 1 10 1 1 10 1 1 1 1 1 1 1 1 1 1 1 1 10 1 1 1 1 1 1 1 1 1 10 1 1 10 1 1 1 1 1 1 1 1 1 1 1 1 1 10 1 10 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 10 1 10 10 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1...

Page 10: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS Gas Fryer LPG Unit continued on next page 10 MODEL CLGF30 LP optional EXPLODED VIEW...

Page 11: ...the authorized parts and service centers near you contact the factory for assistance This warranty does not cover any cost associated with maintenance misuse abuse improper installation pilot light a...

Page 12: ...divisions of Eagle Group 2022 by the Eagle Group 100 Industrial Boulevard Clayton Delaware 19938 8903 U S A Phone 302 653 3000 800 441 8440 Fax 302 653 2065 www eaglegrp com INSTALLATION OPERATING MAI...

Reviews: