background image

INSTALLATION OPERATING & MAINTENANCE INSTRUCTIONS

Gas Fryer (LPG Unit)

7

(continued on next page)

CAUTION:

 Clean exterior of regulator at least once a month. Make sure the vent opening is open 

and not blocked in any way. Failure to do so will cause variations in pressure. Your unit will not 

function as well and it could shorten the life of the product. 

ATTENTION:

 Nettoyer l'extérieur du régulateur au moins une fois par mois. Assurez-vous que 

l'orifice de ventilation est ouvert et n’est pas obstrué de quelque façon que ce soit. Le non-respect 

de cette précaution causera des variations dans la pression. Votre unité ne fonctionnera pas 

comme elle devrait et cela pourrait raccourcir la vie du produit.

CLEANING 

Initial Cleaning 

Always clean equipment thoroughly before first use. Clean the protective oil from the bright parts and 

interior of tank with an appropriate de-greasing solution.  

 
Daily Cleaning 

1. Always turn unit o

ff

 and allow it to cool completely before cleaning. 

2. Never clean unit by immersing it in water. 
3. The frequency of cleaning should depend on the load conditions. Set a definite cleaning schedule 

corresponding to how hard the kettle is used. Cleaning should be done at a least once a week. 

4. Strain the frying compound into a clean container. Make sure there is no compound le

ft

 in tank. (If 

the tank is le

ft

 empty for more than 2 minutes, shut the pilot o

ff

. If this is not done, the tank may be 

damaged.) 

5. Add water to the "MAX" line. 
6. Add any good grade of cleaner following cleaner instructions. 
7. Turn the thermostat to 75°F(dial “°F” position). Let the heating unit bring the solution to a boil. 
8. Boil long enough to loosen or dissolve all varnish or carbon deposits. This should take 

approximately 30 minutes. 

9. Turn the unit o

ff

. Make sure pilot is turned o

ff

 at this time. 

10. If necessary, clean the thermostat probes using a long-handled fiber or plastic brush and mild soap 

solution. 

11. Rinse with clean water to remove all cleaning mixture. 
12. Rinse the inside of the tank with 2 cups of vinegar. 
13. Rinse with clean water until the vinegar odor is gone. The fry tank must be thoroughly rinsed since 

even a trace of cleaner le

ft

 inside the tank will contaminate the fry compound. 

14. Dry thoroughly. 
15. Cover the tank if compound will not be added until a future date. 
16. Clean all exterior surfaces of unit on a regular basis with a damp cloth. Thin films of oil subjected 

to frying temperatures quickly form into gummy consistency. In order to avoid these gum 

formations, clean the surfaces on a regular basis. 

17. To remove discolorations or oil film, a non-abrasive cleaner may be used. 

Summary of Contents for CLGF30-LP

Page 1: ...structions must be posted in a prominent location All safety precautions must be taken in the event the user smells gas Safety information can be obtained from your local gas supplier AVERTISSEMENT Le...

Page 2: ...d arr t manuel pendant tout test de pression du syst me de canalisation de gaz pression de test gale ou inf rieure psi 3 45 kPa TABLE OF CONTENTS ITEM PAGE Safety precautions 3 General Installation In...

Page 3: ...ctice which could result in serious injury or death AVERTISSEMENT Ce symbole d signe un possible danger ou une pratique dangereuse qui pourrait entra ner des blessures graves ou la mort CAUTION This s...

Page 4: ...CLOSE PROXIMITY TO THIS APPLIANCE Combustible clearances 6 sides 152mm 6 rear 152mm 4 floor 102mm Non combustible clearances 0 sides 0mm 0 rear 0mm 4 floor 102mm Do not obstruct the flow of combustio...

Page 5: ...ep 1 Ensure this Gas Control Valve dial is at the OFF position LIGHTIING INSTRUCTIONS Fryers are furnished with a Gas Control Safety Valve Please follow the instructions below Before Lighting Pilot an...

Page 6: ...sides or back Avoid wall type fans which create air cross currents within a room It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air remov...

Page 7: ...e a week 4 Strain the frying compound into a clean container Make sure there is no compound left in tank If the tank is left empty for more than 2 minutes shut the pilot off If this is not done the ta...

Page 8: ...quefy Add to adjust compound level 3 Use a quality frying compound 4 Filter the frying compound frequently at least once a day 5 Skim out food particles frequently with a strainer skimmer 6 Add at lea...

Page 9: ...1 1 1 1 1 1 1 10 1 1 10 1 1 1 1 1 1 1 1 1 1 1 1 10 1 1 1 1 1 1 1 1 1 10 1 1 10 1 1 1 1 1 1 1 1 1 1 1 1 1 10 1 10 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 10 1 10 10 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1...

Page 10: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS Gas Fryer LPG Unit continued on next page 10 MODEL CLGF30 LP optional EXPLODED VIEW...

Page 11: ...the authorized parts and service centers near you contact the factory for assistance This warranty does not cover any cost associated with maintenance misuse abuse improper installation pilot light a...

Page 12: ...divisions of Eagle Group 2022 by the Eagle Group 100 Industrial Boulevard Clayton Delaware 19938 8903 U S A Phone 302 653 3000 800 441 8440 Fax 302 653 2065 www eaglegrp com INSTALLATION OPERATING MAI...

Reviews: