background image

STEAM CONTROL

STEAM CONTROL

Dear Guest,
        Thank  you  very  much  for  purchasing  our  sanitary  ware.  To 
enable  you  to  use  this  product  safely  and  effectively,  please 
read  this  installation  and  operation  manual  carefully  before 
use.

1.

protection device, the power plug contains earth line, and make sure 
it  is  reliable  earth  line.  Check  the  protect  system  of  leakage 
protection each time before use.

2.Do  not  turn  on  water  pump,  heat  pump  or  air  bubble  pump  without 

water.

3.Before  turn  on  water  pump,  check  if  the  water  level  over  jets  10  to 

20  mm  or  not,  make  sure  regular  usage  of  water  pump  otherwise  it 
will be destroy because of water leakage.

4.People with Hypertension symptom, after drink or heart disease are 

not  allowed  to  use  the  bathtub.  Children  have  a  bath  must  under 
adult's guidance.

5.During  use  please  noticed  that  don't  blocked  the  jets  and  avoiding 

the  air  adjustment  valve  overflowing.  Also  keep  the  bathtub  clean 
and don't let it blocked by hair or mess.

6.During  use,  please  firstly  adjust  the  water  temperature  or  it  will  be 

burned.

7.The  bathtub  is  designed  with  ergonomic,  rise  and  fall  changes  are 

quite big so during usage pay more attention of be slipped.

8.Please shut down the system when not to use.

Please  ensure  that  the  product  installed  reliable  electric  leakage 

CAUTIONS: Heat pump and air bubble pump is optional purchase.

CAUTIONS

TECHNIQUE  PARAMETER

60H

Z

0. 1~0 .2M pa

2. 65K W

1K W

0. 2K W

1. 0H P

Vol tage

Freque ncy

Water
Volatge

Power of
steam
generator

Power of
water pump

Power of
heat pump

Power of
air pump

Ac

1

10 

V(

±

10%)

Storage 
capacity

40g al lon

Storage 
capacity

3

0. 18m

Step 1

Step 2

Step 3

Self-clean system

Pour into cleaning 
liquid from here

Step 4

Cleaning method

1.Clean the steam engine regularly at least once by every 2weeks 
or after using 20 times.
2.Inject citric acid as main cleaning liquid,add 1.5L each 
time.after 10 minutes, turn on and When the system turns on, 
press

        

button to start the steam function for about 30seconds 

and then shut down the system.After vent the stagnant 
water,repeat 2 or 3 times.
3.CAUTION: The system must be shut down before injecting 

01

WS

-609

P

14

WS

-609

P

Summary of Contents for WS-609P

Page 1: ...re we change our design and size The pictures may be a little different from the real products Our company keep the final explanation right Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary www eaglebath com ...

Page 2: ...s 6 During use please firstly adjust the water temperature or it will be burned 7 The bathtub is designed with ergonomic rise and fall changes are quite big so during usage pay more attention of be slipped 8 Please shut down the system when not to use Please ensure that the product installed reliable electric leakage CAUTIONS Heat pump and air bubble pump is optional purchase CAUTIONS TECHNIQUE PA...

Page 3: ...e shower holding bar one set of foot massage one piece of steam pipe with plastic pad three pieces of ABS board two pieces of sliding glass door two pieces of fixed glass door two pieces of T shaped pillow one piece of remote control two pieces of round shaped handle one piece of drainage cover four pieces of plastic seal for the post two sets of handle 22 two sets of shower M6 25 screw 1 M6 35 sc...

Page 4: ...do not hang up heavy things on the steam room or the handle of steam room 10 Please deal with the products according to the local laws when it is no longer be use 1 check if power and cold hot water switch be turn on or be turn off each time before use this product 2 check if power of electronic leakage device be get through or not Checking way Press testing button light of power be off press butt...

Page 5: ...ical people can not be fixed or removed at random 11 WS 609P 04 WS 609P Notes 150 59 5 0 0 1 9 7 900 35 4 550 21 7 The socket of power Cold water pipe Hot water pipe 5 0 0 1 9 7 1 Install the steam bathroom in a proper way and have the electrician or professional personnel to install the unit the company won t take the responsibility for any improper installation and usage 2 The application of the...

Page 6: ... the back lamp Press the sidelight is on Press again the ceiling lamp is out press a third press the sidelight is out too 3 The steam function Press startup the steam function the water case will pump water automati cally After 6 minutes or so it will generate steam When the water case is lack ofwater the controller will replenish automatically 4 The air draft function Under the condition of turnn...

Page 7: ...ment pitch Time adjustment pitch Temperature adjustment pitch Temperature adjustment pitch Fan Pitch CeilingLamp Back Lamp pitch Steam Pitch Main Cock Pitch 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 09 WS 609P Step 6 06 WS 609P ...

Page 8: ...Cold water connection blue pipe Hot water connection red pipe Steam generator Nozzle Water fall Drawingofwaterconnection 08 WS 609P DRAWING OF ELECTRICITY CONNECTION steam outlet water inlet water outlet Control panel Power Light AC12V Fan DC12V clean system 07 WS 609P ...