background image

 

 

 

 

 

   

1)  

Install the gate operator only when:

 

The operator is appropriate for the construction and the usage Class of the gate.

 

All openings of a horizontal slide gate are guarded or screened from the bottom of the 

 

gate to a minimum of 4 feet (1.2 m) above the ground to prevent a 2 ¼ inch (57.15 mm) 

 

diameter sphere from passing through the openings anywhere in the gate, and 

 

in that portion of the adjacent fence that the gate covers in the open position.

 

All exposed pinch points are eliminated or guarded. 

 

Guarding is supplied for exposed rollers.

2)  

The operator is intended for installation only on gates used for vehicles. Pedestrians must be 

 

supplied with a separate access opening. 

3)  

The gate must be installed in a location so that enough clearance is supplied between the gate 

 

and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging

 

gates shall not open into public access areas. 

4)  

The gate must be properly installed and work freely in both directions prior to the installation of

 

 the gate operator.

5)  

Controls must be far enough from the gate so that the user is prevented from coming in

 

contact with the gate while operating the controls. Controls intended to be used to reset an 

 

operator after two sequential activations of the entrapment protection device(s) must 

 

be located in the line of sight of the outdoor gate or easily accessible controls shall have a 

 

security feature to prevent unauthorized use.

6)  

All warning signs and placards must be installed where visible in the area of the gate.

7)  

For a gate operator utilizing a non-contact sensor such as a photo beam:

 

See instructions on the placement of non-contact sensor for each type of application.

 

Care shall be given to reduce the risk of nuisance tripping such as when a vehicle

 

 trips the sensor while the gate is still moving.

 

One or more non-contact sensors shall be located where the risk of entrapment or 

 

obstruction exists, such as the perimeter reachable by a moving gate or barrier.

8)      

Gate operators utilizing a contact sensor such as an edge sensor:

 

One or more contact sensors shall be located at the leading edge, trailing edge, and 

 

post mounted both inside and outside of a vehicular horizontal sliding gate. 

 

One or more contact sensors shall be located at the bottom edge of a vehicular lift 

 gate.

 

One or more contact sensors shall be located at the pinch point of a vehicular vertical

 pivot 

gate.

 

A hard wire contact sensor shall be located and its wiring arranged so that the

 

communication between the sensor and the gate operator is not subject to 

 mechanical 

damage.

 

A wireless contact sensor such as one that transmits radio frequency (RF) signals

 

to the gate operator for entrapment protection functions shall be located where the 

 

transmission of the signals are not obstructed or impeded by building structure, 

 

natural landscaping, or similar obstruction. A wireless contact sensor shall function

 

under the intended end use conditions.

   Gate Operators Installation Instructions

UL Listings 

         Distributed by AFW Access Systems • www.AnchorMiami.com/afwas

(3)

Summary of Contents for Eagle-2000 series

Page 1: ...ibuted by AFW Access Systems Phone 305 691 7711 www AnchorMiami com Operator Installation and Instructions for the Eagle 2000 and Eagle 1000 Series Sliding Gate Eagle 2000 Series Eagle 1000 Series UL3...

Page 2: ...Switches Emergency Releases Mounting the Secondary Entrapments Resetting the Motor Control Board LED Indicators Troubleshooting Parts Breakdown Eagle 2000 Parts Breakdown Eagle 1000 Operator Parts Li...

Page 3: ...horized use 6 All warning signs and placards must be installed where visible in the area of the gate 7 For a gate operator utilizing a non contact sensor such as a photo beam See instructions on the p...

Page 4: ...entrance or exit to a drive parking lot or the like UL Listings __________________________________________ Gate A moving barrier such as a swinging sliding raising lowering rolling or like barrier tha...

Page 5: ...ble for any improper installation procedures caused by installer or user failing to comply with local building codes CAUTION ____________________ Precautions Be sure to mount ALL operating devices cle...

Page 6: ...ost with a minimal distance of 4 Four inches between the rollers as shown in Example B Also when fully open the end of the sliding gate must stop at least 3 three inches from any wall or other objects...

Page 7: ...Front Installation Rear Installation ____________________ Proper Chain Installation Minimum space between gate and output sprocket must be 4 After you position the gate operator bolt down the operato...

Page 8: ...mendations are installation suggestions only Please consult local codes for actual requirements in your area Note ____________________ Selecting Opening Direction of Gate Distributed by AFW Access Sys...

Page 9: ..._ Reverse Exit Loop Installation The purpose of a reversing loop is to prevent the gate from closing on a vehicle while it is exiting or stopped in the middle of the gate area The purpose of the exit...

Page 10: ...r closing the gate There is an LED OVERLOAD warning that will light up when the gate is heavier than normal for the operator During this warning the operator will not function properly Too Sensitive i...

Page 11: ...uphill downhill applications and on all Fail Safe operators Distributed by AFW Access Systems www AnchorMiami com afwas 11 Slide Gate Operators Eagle 2000 Series Eagle 1000 Series ___________________...

Page 12: ...r to work as a three button station and is useful for a partial opening If selected the first command will open the gate the second will stop the gate and the third will close the gate Switch 7 Alarm...

Page 13: ...ributed by AFW Access Systems www AnchorMiami com afwas 13 Important Be sure that the 120VAC power for the Master and the Slave are connected to the same circuit breaker Master and Slave Operation ___...

Page 14: ...Selecting the switch to the on position delays the Slave Sw 5 or Master Sw 6 operator by 1 1 2 seconds on the open cycle This is useful with magnetic lock applications Setting The Close Delay Function...

Page 15: ...rovides 24 VAC Power which can be used for loop detectors and receivers Distributed by AFW Access Systems www AnchorMiami com afwas 15 Safety Alarm If the gate hits an obstruction twice while closing...

Page 16: ...the exeption of the MAG Lock all of these accessories can be installed on the Master or Slave operator Distributed by AFW Access Systems www AnchorMiami com afwas 16 Reverse Loop Phantom Loop Exit Loo...

Page 17: ...hile the gate is open will disable the timer to close function from automatically closing the gate Edge Sensor Momentary or Continuous Signal This signal is active when the gate is opening and or clos...

Page 18: ...tches 4 Wire Connections 3 Wire Connections The receiver terminal is mounted on the control box for easy installation and is pre wired for a 3 wire or 4 wire receiver ____________________ Adjust cams...

Page 19: ...drill ____________________ The Fail Safe System Optional Release Procedure Using the Eagle 2070 Fire Box 1 2 3 ____________________ Distributed by AFW Access Systems www AnchorMiami com afwas 19 Pull...

Page 20: ...on is available for resetting the motor If operator ceases to function then simply locate the reset button press and then turn the power back on ____________________ EMERSO MOTOR LEESON MOTOR Edge Sen...

Page 21: ...4 5 6 7 9 11 12 13 14 15 16 17 Distributed by AFW Access Systems www AnchorMiami com afwas 21 10 1 Power On 5 Key Keypad 10 Receiver 15 Overload 2 Master Slave 6 Stop 11 Close Limit 16 Active Communic...

Page 22: ...on position B Check any Global Inputs for a possible short circuit C Only key keypad and receiver will resume normal operation D Reset Loop Detector verify correct wiring set to a differ ent frequenc...

Page 23: ...ystem Model 2000 FSF E181 Model 2000 FSC Model 2000 FSF E255 E256 E257 E266 E277 E166 E167 E168 E333 E292 E293 E555 No Weld Chain Assembly E305 E306 E307 E144 Entire FSC System E301 E242 E194 E132 E13...

Page 24: ...0 No Weld Chain Assembly E305 E306 E307 E185 Fail Secure System Model 1000 FSF Entire Kit E301 E255 E256 E257 E266 Model 1000 FSF E281 Model 1000 FSC E278 E169 E145 E241 E132 E198 E133 E444 E293 E292...

Page 25: ...E031 Motor Harness E032 Receiver Harness E525 Plastic Eagle Logo E300 No Weld Chain Assembly Complete E305 Chain Bracket E306 Chain Bolt w Nuts E307 U Bolts E444 Operator Cover E293 Plastic Control B...

Reviews: