background image

 

                           

  Installation, Operation and Parts Manual   

EE-6605S/A/B  

                                                                                                                         

                               

 

                                         

 

8

PACKING,

 

STORAGE

 

AND

 

TRANSPORTATION

   

Packing,

 

lifting,

 

handling,

 

transporting

 

operations

 

must

 

be

 

performed

 

only

 

by

 

experienced

 

personnel

 

with

 

appropriate

 

knowledge

 

of

 

the

 

lift

 

and

 

after

 

reading

 

this

 

manual.

       

2.1

 

The

 

lift

 

was

 

dismantled

 

into

 

3

 

parts

 

for

 

transportation

   

Name

 

Packed

 

by

 

Dimension(mm)

 

Weight(KG)

 

Quantity

 

Control

 

cabinet

 

Wooden

 

case

 

580*510*1010

 

88

 

1

 

Power

 

side

 

platform

 

Carton

 

with

 

wooden

 

base

 

5640*810*430

 

1450

 

1

 

The

 

opposite

 

platform

 

Carton

 

with

 

wooden

 

base

 

5640*810*430

 

1450

 

1

 

2.2

 

Storage

   

The

 

packs

 

must

 

be

 

kept

 

in

 

a

 

covered

 

and

 

protected

 

area

 

in

 

a

 

temperature

 

range

 

0f

  ‐

10

to

 

+40

.

 

They

 

must

 

not

 

be

 

exposed

 

to

 

direct

 

sunlight,

 

rain

 

or

 

water.

 

Stacking

 

the

 

packs

   

We

 

advise

 

against

 

stacking

 

because

 

the

 

packs

 

are

 

not

 

designed

 

for

 

this

 

type

 

of

 

storage.

 

The

 

narrow

 

base,

 

heavy

 

weight

 

and

 

large

 

size

 

of

 

the

 

packs

 

make

 

stacking

 

difficult

 

and

 

potentially

 

dangerous.

   

If

 

stacking

 

is

 

unavoidable,

 

use

 

all

 

appropriate

 

precautions:

   

never

 

stack

 

to

 

more

 

than

 

2

 

meters

 

in

 

height.

   

never

 

make

 

stacks

 

of

 

single

 

packs.

 

Always

 

stack

 

pairs

 

of

 

packs

 

in

 

a

 

cross

 

pattern

 

so

 

that

 

the

 

base

 

is

 

bigger

 

and

 

the

 

resulting

 

stack

 

is

 

more

 

stable.

 

Once

 

the

 

stack

 

is

 

complete,

 

restrain

 

it

 

using

 

straps,

 

ropes

 

or

 

other

 

suitable

 

methods.

 

A

 

maximum

 

of

 

two

 

packs

 

can

 

be

 

stacked

 

on

 

lorries,

 

in

 

containers,

 

and

 

in

 

railway

 

wagons,

 

on

 

condition

 

that

 

the

 

packs

 

are

 

strapped

 

together

 

and

 

restrained

 

to

 

stop

 

them

 

falling.

   

2.3

 

Lifting

 

and

 

handling

   

The

 

packs

 

can

 

be

 

lifted

 

and

 

transported

 

only

 

by

 

using

 

lift

 

trucks.

   

The

 

center

 

of

 

gravity

 

and

 

lashing

 

points

 

are

 

marked

 

on

 

the

 

packaging.

 

Never

 

attempt

 

to

 

hoist

 

or

 

transport

 

the

 

unit

 

using

 

lifting

 

slings.

   

 

 

 

 

 

Opening

 

the

 

packs

 

When

 

the

 

lift

 

is

 

delivered

 

make

 

sure

 

that

 

it

 

has

 

not

 

been

 

damaged

 

during

 

transportation

 

and

 

that

 

all

 

the

 

parts

 

specified

 

on

 

the

 

packing

 

list

 

are

 

present.

   

Packs

 

must

 

be

 

opened

 

adopting

 

all

 

the

 

precautions

 

required

 

to

 

avoid

 

injury

 

to

 

persons

 

(keep

 

at

 

a

 

safe

 

distance

 

when

 

cutting

 

the

 

straps)

 

or

 

damage

 

to

 

parts

 

of

 

the

 

machine

 

(be

 

careful

 

that

 

no

 

parts

 

are

 

dropped

 

while

 

you

 

are

 

opening

 

the

 

packing)

 

Take

 

special

 

care

 

with

 

the

 

hydraulic

 

power

 

unit,

 

the

 

control

 

panel

 

and

 

the

 

platform

 

cylinder.

   

Summary of Contents for EE-6605S

Page 1: ...issor lift heavy duty Electrical Levelling Lifting Capacity 5500KG Installation Operation and Parts Manual Distributed by Please read this entire manual carefully and completely before installation or...

Page 2: ...and are protected against duplication and reproduction by copyright laws international agreements and other domestic legislation The reproduction or disclosure of instructions or an extract thereof i...

Page 3: ...3 1 General descriptions 9 3 2 General construction of the lift 9 3 3 Dimensions 10 3 4 Technical data 10 INSTALLATION INSTRUCTIONS 11 4 1 Preparations before installation 11 4 2 Installation attenti...

Page 4: ...ersons 1 2 1 Scope of checking Regular checking essentially involves performing a visual inspection and a functional test This includes checking the condition of the components and equipment checking...

Page 5: ...ifting capacity 1 3 9 Always insure the safety locks are engaged before any attempt to work near or under the vehicle Never remove safety related components from the lift Do not use if safety related...

Page 6: ...e clearly depicted on the lift to ensure that the operator is aware of and avoid the dangers of using the lift in an incorrect manner The labels must be kept clean and they have to be replaced if deta...

Page 7: ...crushing In the event of excessive vehicle weight incorrect mounting of the vehicle or on removing heavy object there is a risk of the vehicle falling off the lifting platform or tipping up Safety mea...

Page 8: ...ever stack to more than 2 meters in height never make stacks of single packs Always stack pairs of packs in a cross pattern so that the base is bigger and the resulting stack is more stable Once the s...

Page 9: ...hile oil in the pump will push upwards the pistons of oil cylinders Thus scissor brackets of the lift rise accordingly In the process of rising the mechanical lock automatically engages to avoid sudde...

Page 10: ...4 Technical data Model EE 6605 Rated capacity KG 5500 Full raised height mm 1750 Full lowered height mm 240 Full raised time with rated load 50s Full lowered time with rated load 30s Hydraulic working...

Page 11: ...agent Routing of the wiring to the installation location The user must provide fuse protection for the connection Requirements for power supply cable of the installation site at least 2 5mm2 wire core...

Page 12: ...ng a forklift and 2 lifting straps until the mechanical lock is engaged Dismantle the bolts that fix the platform and its wooden package and then hoist the platform onto the expected installation site...

Page 13: ...d be judged by the way that the oil hose was connected or by trial raising or lowering 1 Connect the power supply and turn on the main power switch 2 Turn the selection switch in the control cabinet t...

Page 14: ...lower an automobile if its center of gravity is not positioned midway of the runways Otherwise we as well as our dealers will not bear any responsibility for any consequence resulted thereby 5 1 4 Ope...

Page 15: ...rm a little bit off the ground and check the stability of the lifted vehicle 4 Having raised the vehicle to the expected height push the Safety Lock button to ensure the mechanical safety lock is enga...

Page 16: ...screwed up or jammed Clean or make adjustment Damaged gear pump Replace it Too low oil level Add oil The hose connection is loose Tighten it The cushion valve is not well screwed up or jammed Clean or...

Page 17: ...d condition Check whether the expansion bolts well anchored Check if safety teeth and safety block matched well or not 6 2 Weekly checking items Check the flexibility of moving parts Check the working...

Page 18: ...ess of 200mm Newly built concrete ground must be older than 20days 2 Concrete thickness of the pit base shall be more than 200mm and remove the peel offs in the bit 3 Flatness of the two pit base shal...

Page 19: ...Installation Operation and Parts Manual EE 6605S A B 19 Floor plan for surface installation...

Page 20: ...Installation Operation and Parts Manual EE 6605S A B 20 Annex 2 Electrical schemes and parts list...

Page 21: ...Installation Operation and Parts Manual EE 6605S A B 21...

Page 22: ...Installation Operation and Parts Manual EE 6605S A B 22...

Page 23: ...Installation Operation and Parts Manual EE 6605S A B 23...

Page 24: ...S 320304001 Power switch LW26GS 20 04 1 SB1 SB4 320401013 Button AR22F0R 11 W 4 SB 320402010 Emergency stop NBP2 BS542 40 1 QF 320801001 Circuit breaker DZ47 63C16 3P 1 QF1 QF2 320803003 Circuit break...

Page 25: ...2 207102013 Y seal ring SD48 58 7 1 Main cylinder 3 207103027 Composite seal ring KGD 110 85 22 4 6 35 1 Secondary oil cylinder 1 Oil tank 2 Oil sucking filter 3 Gear pump 4 Coupling 5 Motor 6 Hydrau...

Page 26: ...4 4 207103025 composite washer 13 7 20 00 1 50 BS224 3 5 210101004 hex socket flat head fitting G1 4 1 6 310101028 shifting connector G1 4M14x1 5 M14x1 5 2 7 330101008 hydraulic block YF 06 1 8 330301...

Page 27: ...CBK F225 G 1 POS CODE Name Specification Qty 1 Power unit 3 5kW 1 2 624001096B Oil hose L 3300mm 1 3 624001093C Oil hose L 3700mm 1 4 310101010 Straight connector G1 4 G1 4 inside swivel 2 5 41026064...

Page 28: ...ombination AFC2000 1 2 310101015 Pneumatic connector KLC8 02 2 3 123010201 Air hose DE8 1 4 310102015 Pneumatic connector KLL8 02 4 5 310201002 Silencer SLM02 R1 4 M12 1 6 310401001 Pneumatic directio...

Page 29: ...unway S and B 5 614026103 Platform A welding 6605S A1 B1 1 6605S 5 614026104 Platform B welding 6605S A2 B1 1 6605S 5 614026203 Platform A welding 6605A A1 B1 1 6605A 5 614026204 Platform B welding 66...

Page 30: ...6 1 29 310102026 PVL air cylinder connector KLV 8 2 30 310201003 Noise muffle SLM 01 2 31 310102024 PLL Swivel two way air hose connector KLL8 01 2 32 410260121B Baffle block B 6605B A14 4 33 4102600...

Page 31: ...of platform 6605B A6 B1 C2 4 69 204301011 Circlip 30 8 70 420210060B Padding block 6603B A5 B6 4 71 410260051 Clamp plate of base B 6605B A8 B2 4 72 410260940 Padding plate for slider 6605B A8 B3 4 73...

Reviews: