5.5 Emergency lowering
Emergency situation means: 1. Electricity power failure 2. Failure on equipment itself
Suitable condition:
Compressed air is available.
Normally, in case of sudden electricity power failure, the compressed air remained can still make the pneumatic system of the lift work.
In the case the mechanical safety locks are not engaged, follow the following steps for emergency lowering.
Attention: Pay careful attention as there could be potential hazards in doing so.
1. Open the control cabinet and find out the manually controlled air-supplying button and emergency unloading solenoid valve.
2. Take off the protective cap of the valve and see red spool of the valve.
3. Push the blue air-supplying button and meanwhile push and turn anticlockwise the red spool until hear sound which implicate the valve
is open. At this time, lifting platforms may lower.
Attention: when do the above operation, operators need to focus on the lowering platform.
If any abnormal occurs, stop pushing the blue air-supplying button and push and turn clockwise the red spool until hear the sound which
implicate the valve is closed.
4. Turn off the unloading valve by pushing and turning clockwise the red spool until hear the sound which implicate the valve is closed.
NOTE: For different models, the pictures showing above may differ from lift to lift, but the methods is the same.
Summary of Contents for EE-6501
Page 10: ...Installation Operation and Parts Manual EE 6501 10 3 3 Dimensions...
Page 14: ...Installation Operation and Parts Manual EE 6501 14 Recessed mounting...
Page 27: ...Installation Operation and Parts Manual EE 6501 27 Annex 1 Wiring diagrams and parts list...
Page 28: ...Installation Operation and Parts Manual EE 6501 28...
Page 37: ...Installation Operation and Parts Manual EE 6501 37...