PRODUCT MANUAL IPR100 

EAE KNX IP ROUTER   

 

 

 

 

    

 

       

IPR100  R1 

 

©

EAE Technology 

 

 

www.eaetechnology.com  

 

               Page 1 / 24 

 

EAE KNX IP ROUTER 

      
 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Order Nr: 48015 

 

Summary of Contents for 48015

Page 1: ...PRODUCT MANUAL IPR100 EAE KNX IP ROUTER IPR100 R1 EAE Technology www eaetechnology com Page 1 24 EAE KNX IP ROUTER Product Order Nr 48015 ...

Page 2: ...ice Technology 5 2 1 Device Peripherals 5 2 2 Function Button 6 2 3 Addressing Mode 7 2 4 KNX Telegrams in the network 8 2 5 IPR100 as Area Coupler 9 2 5 IPR100 as Line Coupler 10 2 6 IPR100 in Mixed Systems 11 3 Technical Data 12 4 Factory Settings 13 5 Technical Drawing 14 6 Application Description 15 7 ETS Parameters 16 7 1 General 16 7 2 IP Configuration 17 7 3 KNX Multicast Address 19 7 4 Set...

Page 3: ...IACK on a frame that is sent by the EAE KNX device itself When the IPR100 sends a message and there is nobody to acknowledge this message the it would repeat the last message up to 3 times In case there is an IACK there will be no repetition The failure mechanism in case of a negative IACK or BUSY is still maintained switching off the filter table with a button on the device without reconfiguring ...

Page 4: ...ommunicate with each other using IP networks 1 5 Coupler The basic functionality of IPR100 is coupling the Ethernet with KNX TP line s IPR100 provides galvanic isolation between the two connected lines Due to the flexibility of IPR100 the coupler can be used as a line coupler e g to connect trough Ethernet several TP lines together as a backbone coupler to connect trough Ethernet several TP areas ...

Page 5: ...d Off Connect IP IP line OK Manual Function Active No IP connection Connect KNX KNX line OK No KNX connection Tx Rx IP Traffic on IP line Transmission Error on IP line No traffic on IP line Tx Rx KNX Traffic on KNX line Transmission Error on KNX line No traffic on KNX line Group Address Filter Route all Block all No route Physical Address Filter Router all Block all No route Programming LED Progra...

Page 6: ...N line and KNX line parameter Manual override functionality is configured in General parameters NOTE The latest downloaded settings parameters and filter table are still available after switching back from Manual operation to Normal operation Very long press 15s LEDs LEDs are on red release button and press again for some sec resets all the parameter to factory default incl physical address ...

Page 7: ...de LED addressing mode Off normal operating mode On addressing mode After receiving the physical address the IPR100 automatically returns from addressing mode to the normal operating mode Button addressing mode Button for switching between normal operating mode and addressing mode for assigning the physical address ...

Page 8: ...Multicast IP address 224 0 23 12 is the defined address for the KNXnet IP from the KNX Association in conjunction with the IANA This address should stay as defined and only changed if it becomes necessary due to the existing network By commissioning it should be regarded that all KNX IP devices which should communicate with one another via IP must use the same IP routing multicast address Settings...

Page 9: ...oupler For this purpose physical address of an area coupler must between 1 0 0 and 15 0 0 Up to 15 areas can be defined with area couplers The following illustration shows the topology with IPR100 as area couplers and LC100 as line couplers IP L IP line KNX L KNX line BC Backbone coupler ML Main line SL Sub line EAE IPR100 EAE IPR100 EAE LC100 EAE LC100 EAE LC100 EAE LC100 EAE LC100 ...

Page 10: ...tem can assume the function of a line coupler For this purpose it must receive the physical address of a line coupler 1 1 0 till 15 15 0 Up to 225 lines can be defined 1 1 0 till 15 15 0 The following illustration shows the topology with IPR100 routers as line couplers IP L IP line KNX L KNX line LC Line coupler EAE IPR100 EAE IPR100 EAE IPR100 ...

Page 11: ...point as an area coupler e g office complex and at another point as a line coupler e g a remote underground garage this is possible It is only necessary to ensure that the IPR100 used as a line coupler uses a line coupler address from a free area IP L IP line KNX L KNX line BC Backbone coupler LC Line coupler ML Main line SL Sub line EAE IPR100 EAE IPR100 EAE IPR100 EAE LC100 EAE LC100 ...

Page 12: ...ddress Temperature range Ambient 5 C 45 C Storage 25 C 55 C Transport 25 C 70 C Humidity max air humidity 95 no moisture condensation Dimensions IPR100 90x36x70 mm Weight IPR100 66g Box Plastic polycarbonate colour grey CE In accordance with the EMC guideline and low voltage NOTE Device default physical address is 15 15 255 In order to configure switch actuator ETS application file knxprod is need...

Page 13: ...vice IP routing multicast address 224 0 23 12 IP subnet mask DHCP IP standard gateway DHCP IP to KNX Group telegrams 0 13 Filter Main group telegrams 14 15 Transmit all Physical telegrams Filter KNX to IP Group telegrams 0 13 Filter Main group telegrams 14 15 Transmit all Physical telegrams Filter Physical Repetition if errors on sub line normal Group Repetition if errors on sub line normal Telegr...

Page 14: ...PRODUCT MANUAL IPR100 EAE KNX IP ROUTER IPR100 R1 EAE Technology www eaetechnology com Page 14 24 5 Technical Drawing ...

Page 15: ... the telegrams or not The coupler reacts to telegrams withgroupaddresses inaccordance withits parameter settings During normal operation default setting the coupler only routes those telegrams whose group addresses have been entered in its filter table If the coupler routes a telegram and does not receive an acknowledgement or if a bus device finds a transmission error the coupler repeats the tele...

Page 16: ...ure 1 General ETS Text Range Default value Comment Host name 30 signs KNX IP Router Field to enter the IPR100 name 30 signs max For an easy search of the device with the ETS or with a KNXnet IP visualization system Enable slow connections enable disable disable Enable to support slow tunneling connections Table 1 Parameter General ...

Page 17: ...ww eaetechnology com Page 17 24 7 2 IP Configuration Picture 2 DHCP Configuration ETS Text Range Default value Comment DHCP use do not use use If DHCP is used no parameterisation needed If DHCP is not used following parameters are to be set Table 2 DHCP Configuration ...

Page 18: ... do not use use If DHCP is not used following parameters are to be set IP Address IP Byte 1 IP Byte 2 IP Byte 3 IP Byte 4 0 255 0 255 0 255 0 255 IP Byte 1 to 4 manual input Net mask NM Byte 1 NM Byte 2 NM Byte 3 NM Byte 4 0 255 0 255 0 255 0 255 Net mask Byte 1 to 4 manual input Gateway GW Byte 1 GW Byte 2 GW Byte 3 GW Byte 4 0 255 0 255 0 255 0 255 Gateway Byte 1 to 4 manual input Table 3 Manual...

Page 19: ...st address is used Byte 3 0 255 0 255 23 Third byte of the IP routing multicast address Can only be set manually if an individual multicast address is used Byte 4 0 255 0 255 12 Fourth byte of the IP routing multicast address Can only be set manually if an individual multicast address is used Table 4 KNX Multicast Address NOTE The Multicast IP address 224 0 23 12 is the defined address for the KNX...

Page 20: ... ETS Text Range Default value Comment Fallback time for manual operation 10 min 1 hour 4 hours 8 hours 1 hour Time duration required to exit from manual operation Manual function Disabled Pass all telegrams Pass physical telegrams Pass group telegrams pass all telegrams Telegram routing configuration for the manual function Table 5 Parameter General ...

Page 21: ...MANUAL IPR100 EAE KNX IP ROUTER IPR100 R1 EAE Technology www eaetechnology com Page 21 24 7 5 Main Line Picture 6 Main Line Configuration Picture 7 Main Line Group or Physical Telegrams Individual Configuration ...

Page 22: ...s 1 transmit all for testing only 2 Block 3 filter filter 1 All group telegrams are transmitted 2 No group telegram is transmitted 3 Only group telegrams are routed which are entered in the filter table The ETS 3 4 produces the filter table automatically Main group telegrams 14 15 1 transmit all 2 block transmit all 1 Group telegrams with the main group 14 or 15 e g 14 1 are routed 2 Group telegra...

Page 23: ...hysical filter groups physical route configure groups physical filter Block no telegram is routed Filter Only telegrams are routed which are entered in the filter table Route the telegrams are routed Configure the following parameters can be set individually This parameter is to be set depending on the planed configuration Group telegrams 1 transmit all for testing only 2 block 3 filter filter 1 A...

Page 24: ...found when sending a physical telegram on the sub line 1 The physical telegram is not repeated 2 The physical telegram is repeated up to 3 times 3 The physical telegram will be repeated only one time Group Repetition if errors on sub line 1 no 2 normal 3 reduced normal If a transmission error e g due to missing receiver is found when sending a group telegram on the sub line 1 The group telegram is...