![e2v ELIIXA+ User Manual Download Page 46](http://html1.mh-extra.com/html/e2v/eliixa/eliixa_user-manual_3239177046.webp)
® 16k/8k CXP Color
46
e2v semiconductors SAS 2014
Feature
CXP @
Size
in
bytes
Description
By default
TestImageSelector
0x08214
4
0:Set test (output FPGA) image pattern to “Off”, processing
chain activated
1: Set test (output FPGA) image pattern to
“GreyHorizontalRamp”, processing chain disabled
2: Set test (output FPGA) image pattern to “White pattern”,
processing chain disabled
3: Set test (output FPGA) image pattern to “gray pattern”,
processing chain disabled
4: Set test (output FPGA) image pattern to “Black pattern”,
processing chain disabled
5: Set test (output FPGA) image pattern to
“GreyVerticalRampMoving”, processing chain disabled
0
InputSource
0x08218
4
0: Set signal source to CMOS sensor, processing chain
activated
0
Color Selection
0x08230
4
Disable color components
Bit 0 : Disable Red color
Bit 1 : Disable Blue color
Bit 2 : Disable Green colors (both Green
Red
and Green
Blue
)
12.3
Synchro and Acquisition modes
Feature
CXP @
Size
in
bytes
Description
By default
LinePeriod
0x08400
4
Set line period, from from 1 (0,1µs) to 65535 (6553,5µs), step
1 (0,1µs)
500
LinePeriodMin
0x08404
4
Get current line period min (0..65535 step 0,1µs)
Depends on Sensor
mode
AcquisitionLineRate
Xml
= 1 / LinePeriod en Hertz
ExposureTime
0x08408
4
Set exposure time, from 1 (0,1µs) to 65535 (6553,5µs), step 1
(0,1µs)
500
TriggerPreset
0x0840C
4
0: Set trigger preset mode to Free run timed mode, with
exposure time and line period programmable d
1: Set trigger preset mode to Triggered mode with exposure
time settings
2: Set trigger preset mode to Triggered mode with maximum
exposure time
3: Set trigger preset mode to Triggered mode with exposure
time controlled by one signal
4: Set trigger preset mode to Triggered mode with exposure
time controlled by two signals
5: Set trigger preset mode to Freerun mode, with max
exposure time and programmable line period
5
12.4
Scan Direction
Feature
CXP @
Size
in
bytes
Description
By default
ScanDirectionMode
0x0820C
4
0: Set scan direction to “forward”
1: Set scan direction to “reverse”
2: Set scan direction to “Externally controlled direction via
External Line on I/O Connector (0 : forward, 1 : reverse)
0
ExternalLine
0x08570
4
0: Line0
1: Line1
0