ELiiXA® UC8/UC4
37
Eliixa_Color–revF 04/11
e2v semiconductors SAS 2011
For example val = 14 means that the lines Blue + Green + Nir (or Mono) will be
processed.
The value switches back to 0 automatically when the balance process is finished (“Gain
Balance control” in CommCam)
“
w balg 0
” : Stops the Gain balance. No action is the process is already finished
(“Abort Gain balance Control” in CommCam).
•
Tap Balance Bank Management
:
The new-processed Tap balance can be saved in 4 x User banks (both
Gains and Offsets in the same time).
Ö
Read function
“
r rbal
” : Get the current Tap Bank used (0: Factory or 1 to 4)
“
w rbal <val>
” : Load Tap Bank from bank <val> (0: Factory or 1 to 4)
Ö
Write function :
“
w sbal
<val>
” : Save the current Tap Balance in the User bank <val> (1 to 4)
Contrast Expansion
•
Digital Gain
:
Set the global Digital Gain
.
This command is available in the CommCam “Gain & Offset”
section :
Ö
Read function : “
r gdig
”;
Returned by the camera : Value from 0 to 255. The corresponding Gain is calculated as
20log(1+val/64) in dB
Ö
Write function : “
w gdig
” <int> ;
•
Digital Offset
:
Set the global Digital Offset
.
This command is available in the CommCam “Gain & Offset”
section :
Ö
Read function : “
r offs
”;
Returned by the camera : Value from –4096 to +4095 in LSB
Ö
Write function : “
w offs
” <int> ;