background image

 e2v technologies (uk) limited 2013 

CR 113590 

P7250UM version 4, page 8 

 

Direct Temperature Measurement 

The  Argus

®

  F-Type  allows  the operator to view 

the average temperature of the centre spot of the 
scene (defined by the target markings).  The 

temperature reading is displayed in the bottom right-hand corner of the display. 
This system is intended to give the operator the ability to detect possible 
hazards or heat signatures of people or objects. 

 

The camera can be configured to give a reading in degrees Celsius or degrees 
Fahrenheit by using the user software or the on screen menu. Scene 
temperatures between -40 and +200 

°

C (-40 and +392 

°

F) can be displayed. 

This feature can be turned off if not required by using the software provided or 
the on screen menu.

 

 

Note

: If the object in the scene does not fully fill the target marks then a false 

reading may be obtained. 
Different materials have differing surface emissivities, which will produce 
variations in the temperature readings. Variations can also be caused by the 
distance from the object. This temperature measurement must be regarded as 
an indication and not a guaranteed reading. 
If the temperature falls outside the maximum value, the display will show “+++“.

 

 

 

SceneSave

TM

 Image Capture 

Up to 100 images can be captured and stored in the Argus

®

 F-Type. 

These images can then be viewed or deleted using the on screen 
menu or software provided. See section 2 for details of on screen 
menu. Using the software provided, captured images can be 

downloaded to a suitable laptop/PC in several formats. 

 

To capture an image, press the left-hand button. The image capture symbol 
appears for a short time above the ambient temperature reading  and the 
number of the image out of 100 will also be indicated on the display. 

 

If the image capture button is pressed and the camera already has 100 images 
stored, a ‘CAMERA FULL’ warning will appear. Before further images can be 
captured, unwanted images will need to be deleted using the on screen menu or 
software. 

Summary of Contents for argus

Page 1: ...the camera at a source of extreme temperature e g the sun as this can damage the detector e2v technologies recommends that the Argus F Type is stored in the supplied case or storage mount Failure to...

Page 2: ...1 3 Camera Features 6 1 4 Display Warning Graphics 10 1 5 Operating Notes 11 2 Menu Control Functions 12 3 Rechargeable Battery Pack and Battery Charger 15 4 Software 18 5 Cleaning Maintenance and Re...

Page 3: ...n be used for Search and rescue of casualties and fugitives Seeing in zero visibility conditions and significantly improving safety Detecting someone penetrating a border even under the cover of darkn...

Page 4: ...iguration 1 2 3 4 5 6 7 1 Rear Bumper 5 Battery Release Button 2 Battery 6 Side Strap 3 USB Data Lead Socket 7 Removable Handle 4 Front Bumper 1 2 3 4 5 6 7 8 9 1 Date 6 Time 2 Spot Temperature Target...

Page 5: ...ill bring up the on screen menu while a long 8 second press will go through the menu and turn off the camera After switch on and for approximately 5 seconds a start up screen will be displayed on the...

Page 6: ...hot objects appear green o Night Seeker Green Black Hot Colourises the picture using a green tint where hot objects appear black o Night Seeker Red White Hot Colourises the picture using a red tint w...

Page 7: ...range Note that with this mode the image may contain large areas of black and white if the whole current image has large areas that differ widely from the central spot especially in the 1 C range sett...

Page 8: ...ing surface emissivities which will produce variations in the temperature readings Variations can also be caused by the distance from the object This temperature measurement must be regarded as an ind...

Page 9: ...range for this mode is between 20 C and 200 C 4 F and 392 F Zoom A short press on the right hand button operates the zoom function Each press of the button changes the zoom status The zoom will scroll...

Page 10: ...g temperature warning is present the camera is very close to its absolute operating limit and the image will start to degrade considerably The user must remove the unit from the high ambient temperatu...

Page 11: ...hot radiator may appear darker than for example burning materials Search for Persons and Objects The camera is not restricted to locating fugitives In many cases the user will be using the camera to s...

Page 12: ...as been selected press the centre button to access further actions described below Pressing the centre button again will perform or set the action and return to the previous menu Scrolling down to the...

Page 13: ...ch Mode White Hot Search Mode Black Hot Compare Mode White Hot Compare Black Hot Selecting off returns to the previous chosen colour scheme in standard automatic mode Display Stored Images The stored...

Page 14: ...emperature Units F Spot Off Select the preferred option to set this in the camera Language Select the preferred option to set this in the camera About This screen shows a number of diagnostic items Pr...

Page 15: ...ttery pack provides an output to the battery status Indicator on the camera display This battery status indicator provides a continuous colour display of the remaining charge allowing the user to avoi...

Page 16: ...rechargeable battery Disposal of batteries should be in line with local procedures and they should be segregated from domestic waste Alternatively the batteries may be returned to e2v technologies fo...

Page 17: ...ing finished Maintenance mode To charge another battery Remove charged battery Wait for yellow before inserting next battery 30 seconds Other indications Battery cold 0 C 32 F slow charging Fast charg...

Page 18: ...tware The customer software allows the user to perform the following tasks View and download images to the PC and save them in standard formats bmp and jpg Save images for later manipulation Delete im...

Page 19: ...d will invalidate the warranty THERE ARE NO OTHER USER SERVICEABLE PARTS Handle P7250HA To remove the handle spin the large thumbwheel anti clockwise until the handle detaches from the camera body Ref...

Page 20: ...200 C 40 F to 1832 F via 2 ranges with auto switching Refresh rate 60 Hz Spot temperature range 40 C to 1000 C 32 F to 1832 F Lens Lens material Germanium Focal length 8 6mm P7250 series 19mm P7225 s...

Page 21: ...ling IP67 Charging temperature 0 C to 40 C 32 F to 104 F 65 C 150 F can be tolerated Charger input voltage 100 240 VAC 50 60 Hz 1 A max Charger operating temperature 0 C to 40 C 32 F to 104 F Video Ou...

Page 22: ...is contract THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY AND IS STRICTLY LIMITED TO THE TERMS HEREOF e2v SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR OF F...

Page 23: ...t was encoded by a customer engaged in a personal and non commercial activity and or was obtained from a video provider licensed by MPEG LA to provide MPEG 4 video No license is granted or shall be im...

Page 24: ...Argus F Type User s Manual...

Page 25: ...93493 Facsimile 44 0 1245 492492 e2v technologies inc 520 White Plains Road Suite 450 Tarrytown NY 10591 USA Telephone 914 592 6050 Facsimile 914 592 5148 e2v technologies sas 16 Burospace F 91572 Bi...

Reviews: