European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH

 

www.e2s.com

 

Tel: +44 (0)208 743 8880

 

Document No. D199-00-201-IS

 

Issue 4

 

07-10-21

 

 

Sheet 7 of 7

 

 

Remove the guard and replace the old lens with the new lens.  
 

 

Figure 8: Changing of Lens.

 

 
Fit the guard back on to the lens and casting, align the holes 
of the guard, lens and casting. To reattach the lens, the fixings 
MUST be in the order shown in figure 9.    
 

 

Figure 9: Lens & Guard Fixings Order.

 

 

11) Maintenance, Overhaul and Repair 

 

Maintenance,  repair  and  overhaul  of  the  equipment  should 
only  be  carried  out  by  suitably  qualified  personnel  in 
accordance with the current relevant standards: 
 

EN60079-19/IEC60079-19  Explosive  atmospheres 

 

Equipment repair, overhaul and reclamation 
 
EN  60079-17/IEC60079-17  Explosive  atmospheres 

 

Electrical installations inspection and maintenance 

 
Units  must  not  be  opened  while  an  explosive  atmosphere  is 
present. 
 
If  opening  the  unit  during  maintenance  operations  a  clean 
environment must be maintained and any dust layer removed 
prior to opening the unit. 
 
Potential  electrostatic  charging  hazard  -  Clean  only  with  a 
damp cloth. 
 
 
 
 
 
 
 
 

 
 

 

 
 
 
 
 
 
 
 

 

 

Summary of Contents for STExB2X05DC012

Page 1: ...Vac 110 120Vac 50 60Hz 140mA 200mA STExB2X05AC230 230Vac 220 240Vac 50 60Hz 70mA 100mA STExB2X10DC024 SIL 24Vdc 20 28Vdc 605mA 710mA STExB2X10DC048 48Vdc 42 54Vdc 230mA 250mA STExB2X10AC115 115Vac 110...

Page 2: ...4 X15DC048 Ex db IIC T4 Gb Ta 50 C to 70 C Ex tb IIIC T127 C Db Ta 55 C to 70 C STExB2 X15AC115 X15AC230 Ex db IIC T3 Gb Ta 50 C to 70 C Ex db IIC T4 Gb Ta 50 C to 65 C Ex tb IIIC T131 C Db Ta 55 C to...

Page 3: ...th the National Electric Code Canadian Electric Code 4 Zones Gas Group Category and Temperature Classification The units can be installed in locations with the following conditions Area Classification...

Page 4: ...les to the beacon it is necessary to remove the flameproof cover to gain access to the flameproof chamber To access the Ex d chamber loosen the M4 grub screw on the beacon cover Open the enclosure by...

Page 5: ...h large cross sectional areas such as 2 5mm Earthing Internal earthing connections should be made to the Internal Earth terminal in the base of the housing using a ring crimp terminal to secure the ea...

Page 6: ...sser 8 Flash Pattern Settings 6 1 Flash Rate Setting The STExB2 beacons can produce different flash patterns as shown in Table 2 The flash patterns are selected by operation of the flash setting DIP s...

Page 7: ...Maintenance Overhaul and Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards EN60079 1...

Page 8: ...R DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT S...

Page 9: ...NGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO...

Page 10: ...Netherlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIC T6 T3 Gb II 2D Ex tb IIIC T...

Page 11: ...e and Place of Issue London 03 12 2021 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Reviews: