2)  Warnings  

 

 

 

  POTENTIAL ELECTROSTATIC CHARGING HAZARD. 

  DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS 

PRESENT. 

  ALL ENTRIES M20 X 1.5MM. 

  USE  SUITABLE  RATED  CABLES  AND  CABLE  GLANDS 

IF  TEMPERATURE  EXCEEDS  AS  PER  STANDARDS 
INDICATIONS BELOW. 
FOR ATEX / IECEx STANDARDS: 

70ºC AT ENTRY OR 80ºC AT BRANCHING POINT. 

FOR NEC / CEC STANDARDS: 

60ºC AT ENTRY OR 60ºC AT BRANCHING POINT. 

 

3)  Marking & Rating Information 

 
All  units  have  a  rating  label,  which  carries  the  following 
important information: 
 

  Unit Model. 

  Voltage Range 

  Nominal Voltage 

  Max. Current 

 
See Table 1 for electrical ratings of each Unit Model. 
 

3.1. ATEX / IECEx Ratings 

 

Standards 

EN IEC 60079-0:2018 / IEC60079-0:2017 (Ed 7): 

Explosive Atmospheres - Equipment. General Requirements 

EN60079-1:2014 / IEC60079-1:2014 (Ed 7): 

Explosive Atmospheres - Equipment Protection by Flameproof 
Enclosures "d" 

BS EN 60079-31:2014 / IEC 60079-31:2013 (Ed 2): 

Explosive Atmospheres - Equipment Dust Ignition Protection by 
Enclosure "t" 

Ratings 

STExB2: 
X05DC012 
X05DC024* 
X05DC048 

Ex db IIC T5 Gb Ta -50°C to +70°C 
Ex db IIC T6 Gb Ta -50°C to +55°C 
Ex tb IIIC T92°C Db Ta -50°C to +70°C 

STExB2: 
X05AC115 
X05AC230 

Ex db IIC T4 Gb Ta -50°C to +70°C 
Ex db IIC T5 Gb Ta -50°C to +55°C 
Ex db IIC T6 Gb Ta -50°C to +40°C 
Ex tb IIIC T110°C Db Ta -50°C to +70°C 

STExB2: 
X10DC024* 
X10DC048 

Ex db IIC T4 Gb Ta -50°C to +70°C 
Ex db IIC T5 Gb Ta -50°C to +45°C 
Ex tb IIIC T118°C Db Ta -50°C to +70°C 

STExB2: 
X10AC115 
X10AC230 

Ex db IIC T4 Gb Ta -50°C to +70°C 
Ex tb IIIC T128°C Db Ta -50°C to +70°C 

STExB2: 
X15DC024* 
X15DC048 

Ex db IIC T4 Gb Ta -50°C to +70°C 
Ex tb IIIC T127°C Db Ta -55°C to +70°C 

STExB2: 
X15AC115 
X15AC230 

Ex db IIC T3 Gb Ta -50°C to +70°C 
Ex db IIC T4 Gb Ta -50°C to +65°C 
Ex tb IIIC T131°C Db Ta -55°C to +70°C 

STExB2: 
X21DC024 
X21DC048 

Ex db IIC T3 Gb Ta -50°C to +70°C 
Ex db IIC T4 Gb Ta -50°C to +65°C 
Ex tb IIIC T131°C Db Ta -50°C to +70°C 

STExB2: 
X21AC115 
X21AC230 

Ex db IIC T3 Gb Ta -50°C to +65°C 
Ex db IIC T4 Gb Ta -50°C to +55°C 
Ex tb IIIC T137°C Db Ta -50°C to +65°C 

*SIL Suitable 

 

Certificate No. 

DEMKO 16 ATEX1466X 
IECEx ULD 16.0017X 

ATEX Mark, Equipment 
Group and Category: 

 

II 2G 
II 2D

 

CE Marking and 
Notified Body No. 

 

2813 

 

3.2. NEC / CEC Ratings 

 

 

 
All  models  are  approved  for  use  as  Visual  Signal  Device  for 
use as General Signalling: 
 

UL1638A & CSA C22.2 No 205-17 

 

NEC Class / Zone Ratings US Codes 

 

Standards 

UL 60079-0 (Ed. 7) 04/15/2020 

Explosive Atmospheres - part 0: Equipment - General 
Requirements  

UL 60079-1 (Ed. 7) 2015 

Explosive Atmospheres - Part 1: Equipment Protection by 
Flameproof Enclosures 'd' 

Ratings 

STExB2: 
X05DC012 
X05DC024* 
X05DC048 

Class I Zone 1 AEx db IIC T5 Gb Ta -50°C to +70°C 
Class I Zone 1 AEx db IIC T6 Gb Ta -50°C to +55°C 

STExB2: 
X05AC115 
X05AC230 

Class I Zone 1 AEx db IIC T4 Gb Ta -50°C to +70°C 
Class I Zone 1 AEx db IIC T5 Gb Ta -50°C to +55°C 
Class I Zone 1 AEx db IIC T6 Gb Ta -50°C to +40°C 

STExB2: 
X10DC024* 
X10DC048 

Class I Zone 1 AEx db IIC T4 Gb Ta -50°C to +70°C 
Class I Zone 1 AEx db IIC T5 Gb Ta -50°C to +45°C 

STExB2: 
X10AC115 
X10AC230 

Class I Zone 1 AEx db IIC T4 Gb Ta -50°C to +70°C 

*SIL Suitable 

 
Installation must be carried out in compliance with the National 
Electric Code. 
 

CEC Class / Zone Ratings Canada 

 

Standards 

CAN/CSA C22.2 No. 60079-0 (Ed. 4) 02/2019 

Explosive Atmospheres - Part 0: Equipment - General 
Requirements  

CAN/CSA C22.2 No. 60079-1 (Ed. 3) 2016 

Electrical Apparatus for Explosive Gas Atmospheres - Part 1: 
Flameproof Enclosures 'd' 

Summary of Contents for STExB2X05DC012

Page 1: ...Vac 110 120Vac 50 60Hz 140mA 200mA STExB2X05AC230 230Vac 220 240Vac 50 60Hz 70mA 100mA STExB2X10DC024 SIL 24Vdc 20 28Vdc 605mA 710mA STExB2X10DC048 48Vdc 42 54Vdc 230mA 250mA STExB2X10AC115 115Vac 110...

Page 2: ...4 X15DC048 Ex db IIC T4 Gb Ta 50 C to 70 C Ex tb IIIC T127 C Db Ta 55 C to 70 C STExB2 X15AC115 X15AC230 Ex db IIC T3 Gb Ta 50 C to 70 C Ex db IIC T4 Gb Ta 50 C to 65 C Ex tb IIIC T131 C Db Ta 55 C to...

Page 3: ...th the National Electric Code Canadian Electric Code 4 Zones Gas Group Category and Temperature Classification The units can be installed in locations with the following conditions Area Classification...

Page 4: ...les to the beacon it is necessary to remove the flameproof cover to gain access to the flameproof chamber To access the Ex d chamber loosen the M4 grub screw on the beacon cover Open the enclosure by...

Page 5: ...h large cross sectional areas such as 2 5mm Earthing Internal earthing connections should be made to the Internal Earth terminal in the base of the housing using a ring crimp terminal to secure the ea...

Page 6: ...sser 8 Flash Pattern Settings 6 1 Flash Rate Setting The STExB2 beacons can produce different flash patterns as shown in Table 2 The flash patterns are selected by operation of the flash setting DIP s...

Page 7: ...Maintenance Overhaul and Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards EN60079 1...

Page 8: ...R DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT S...

Page 9: ...NGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO...

Page 10: ...Netherlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIC T6 T3 Gb II 2D Ex tb IIIC T...

Page 11: ...e and Place of Issue London 03 12 2021 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Reviews: