  Cable Connections 

 

The  cable  connections  are  made  into  the  terminal  blocks  on 
the  pcb  assembly  located  in  the  flameproof  enclosure.  See 
section  8  of  this  manual  for  access  to  the  flameproof 
enclosure. The 70V and 100V Line loudspeakers are fitted with  
 
a  five  way  terminal  block.  Terminal  A  is  common  and  one  of 
the other terminals B, C, D or E should be selected depending 
on what output level is required (see table below). 
 

 

 

 

 

Terminals 

GNExL2 (25W)         GNExL1 (15W) 

 
A - B 

 

     25W   

 

15W 

A - C 

 

     12.5W 

 

7.5W 

A - D 

 

     6W   

 

3W 

A - E 

 

     2W   

 

1W 

 
A single solid or stranded wire with a cross sectional area of up 
to 4mm² can be connected to each terminal way or if an input 
and  output  wire  is  required  two  2.5mm²  wires  can  be 
connected to each terminal way. When connecting wires to the 
terminals great care should be taken to dress the wire so that 
when  the  cover  is  inserted  into  the  chamber  the  wires  do  not 
exert  excess  pressure  on  the  terminal  blocks.  This  is 
particularly  important  when  using  cables  with  large  cross 
sectional areas such as 2.5mm² and above. 
 
Wire  insulation  needs  to  be  stripped  6-7mm.  Wires  may  be 
fitted securely with crimped ferrules. Terminal screws need to 
be tightened down with a tightening torque of 0.56Nm / 5 Lb-in.  
 
The unit will be set as standard to 100V line. But can be easily 
altered to 70V line by moving the red selection cable from the 
100V  line  terminal  to  the  70V  line  terminal  (see  figure  4  for 
position). 
 
 
 
 
 
 
 
 
 

 

 

 

GNExL2  and  GNExL1  8  ohm  and  16  ohm  low  impedance 
loudspeakers  have  dual  input  terminals  on  the  pcb  assembly 
for  input  and  output  wiring.  A  cable  of  up  to  2.5mm²  can  be 
connected  to  each  terminal.  If  dc  line  monitoring  is  used  cut 
the  link  on  the  board  (see  figure  5  and  section  14  of  this 
manual). 
 

14) 

  End of Line DC Monitoring 

 

 

On GNExL2 and GNExL1 loudspeakers, dc line monitoring can 
be used if required. Both the 70V and 100V Line units and the 
Low Impedance units have blocking capacitors fitted. It should 
be noted that each loudspeaker has a 1M ohm bleed resistor 
connected  across  the  blocking  capacitor  and  this  should  be 
taken into account when selecting the value of the end of line 
monitoring resistance. 
 
The  end  of  line  monitoring  resistor  can  be  connected  across 
the  terminals  on  the  end  of  line  unit.  On  the  low  impedance 
units  care  must  be  taken  with  the  polarity  of  the  monitoring 
voltage. 
 
On 100V and 70V line units the end of line resistor used must 
have a minimum resistance value of 4k7 ohms and a minimum 
wattage of 2.5 watts 
 
On  low  impedance  units  the  end  of  line  resistor  used  must 
have a minimum resistance value of 2k ohms and a minimum 
wattage  of  0.5  watts  or  a  minimum  resistance  value  of  500 
ohms  and  a  minimum  wattage  of  2  watts.  On  the  low 
impedance  units  care  must  be  taken  with  the  polarity  of  the 
monitoring  voltage.  If  an  end  of  line  resistor  is  fitted  to  a  unit 
the links on the printed circuit boards of all loudspeakers in the 
line must be cut for the dc blocking capacitors to be in circuit in 
order to dc monitor the line (see figure 5). 
 
 
 

Figure 4 

Figure 5 

GNExL2 and GNExL1 70V and 100V Line Loudspeakers 

GNExL2 and GNExL1 8 ohm and 16 ohm Loudspeakers 

- - + + 

Link 

Power Setting 
Terminals A - E 

70/100V Line 
Setting Terminal 