        INSTRUCTION MANUAL  (ATEX) 

GNExL2 and GNExL1   

Flameproof Loudspeakers

 

 
 
 
 
 
1) Introduction 

 
The  GNExL2  and  GNExL1  are  second  generation  flameproof 
loudspeakers  which  are  certified  to  meet  the  requirements  of 
the  ATEX  directive  94/9/EC  and  the  IECEx  scheme.  The 
loudspeakers  can  be  used  in  hazardous  areas  where 
potentially flammable atmospheres may be present. There are 
four  versions  of  each  loudspeaker,  8  ohm  or  16  ohm  and 
70V/100V  Line  transformer.  On  70V/100V  line  transformer 
units  there  are  four  output  tappings  for  each  size  of 
loudspeaker.  The  GNExL2  unit  produces  output  levels  in  the 
117dB(A)  range  and  the  GNExL1  unit  produces  output  levels 
in the 112dB(A) range.  
The  loudspeakers  are  Group  II,  EPL  (equipment  protection 
level)  Gb.  Dependant  on  unit  type  and  ambient  temperature 
the equipment is certified ‘Ex db IIC Gb’ and as such may be 
used in Zones 1 and 2 with flammable gases and vapours with 
apparatus groups IIA, IIB & IIC and temperature Classifications 
of T1, T2, T3 and T4 dependant on ambient temperature, see 
marking codes in section 2. 
The equipment is also certified ‘Ex db IIB Gb’ and as such may 
be used in Zones 1 and 2 with flammable gases and vapours 
with  apparatus  groups  IIA  &  IIB  and  temperature 
Classifications  of  T1,  T2,  T3,  T4,  T5  and  T6  dependant  on 
ambient temperature, see marking codes in section 2. 

 

2)  

Marking

 

 
All  units  have  a  rating  label,  which  carries  the  following 
important information:- 
 
Unit Type No.     GN

ExL2  or   

GN

ExL1

 

 
Impedance:        8 ohm or 16 ohm   

            70V Line or 100V Line 
 

Codes:   GNExL1 
 

 

Ex db IIC T4 Gb for Ta –60°C to +50°C 

 

 

Ex db IIC T3 Gb for Ta –60°C to +70°C 

     

Ex db IIB T6 Gb for Ta –60°C to +50°C 

 

 

Ex db IIB T5 Gb for Ta –60°C to +65°C 

 

 

Ex db IIB T4 Gb for Ta –60°C to +70°C 

 

Codes:   GNExL2 

 

 

Ex db IIC T4 Gb for Ta –60°C to +50°C 

 

 

Ex db IIC T3 Gb for Ta –60°C to +65°C 

     

Ex db IIB T6 Gb for Ta –60°C to +50°C 

 

 

Ex db IIB T5 Gb for Ta –60°C to +65°C 

 

Certificate No.

     SIRA  13ATEX1139X 

IECEx SIR 13.0029X

 

        

 

        

 

 

 
 
 
 
 
 

 

 

 

“Warnings” 
 

DO NOT OPEN WHEN ENERGISED 

 

DO  NOT  OPEN  WHEN  AN  EXPLOSIVE  ATMOSPHERE  MAY  BE 
PRESENT 
 
ELECTROSTATIC HAZARD - CLEAN ONLY WITH A DAMP CLOTH 
 
IF  TEMPERATURE  EXCEEDS  70ºC  AT  ENTRY  OR  80ºC  AT 
BRANCHING  POINT  USE  SUITABLY  RATED    CABLE  AND  CABLE 
GLANDS 
 

Year of Construction /  
Serial No.      

 

 i.e.   20 / 1GL25000001

 

 

3) 

Type Approval Standards

 

 

The  loudspeakers  have  an  EC  Type  examination  certificate 
issued  by  SIRA  and  have  been  approved  to  the  following 
standards:- 
 

EN60079-0:2018   EN IEC60079-0:2018             

General Requirements 

 

EN60079-1:2014 A/C:2018   EN 60079-1:2014

 

ed. 7

  

           Flameproof Enclosure ‘d’ 

4) 

Special Conditions for Safe Use

 

 

4.1) Installation 
 

The  sounders  must  be  installed  in  accordance  with  the  latest 
issues  of  the  relevant  parts  of  the  EN  60079  and  IEC60079 
standards  –  Selection,  Installation  and  maintenance  of 
electrical  apparatus  for  use  in  potentially  explosive 
atmospheres  (other  than  mining  applications  or  explosive 
processing and manufacture):- 
 

EN60079-14:2008

    

Electrical Installations in Hazardous 

IEC60079-14:2007 (Ed4) 

Areas (other than mines)

 

 

EN60079-10-1:2009 

Classification of Areas, Gas 
Atmosphere 

IEC60079-10:2008 (Ed1) 
 

The  installation  of  the  units  must  also  be  in  accordance  with 
any local codes that may apply and should only be carried out 
by  a  competent  electrical  engineer  who  has  the  necessary 
training. 
 

4.2) Specific Conditions 

 
Flameproof joints shall not be repaired or modified in any way 
(See figures 1 & 2 for location of flameproof joints). 
 
The  enclosure  is  non-conducting  and  under  certain  extreme 
conditions  may  generate  an  ignition  capable  level  of 

2813 

II  2G 

Epsilon x: 
Equipment Group  
and Category: 

CE Marking: 
Notified Body No. 