2.2 NEC Class / Zone ratings US 

 

The E2xS2 alarm horn complies with the following standards: 

 

UL 60079-0-2013 
UL 60079-15-2013 

UL 60079-31-2015 

 

The E2XS2 Alarm horn is rated as follows: 
 

Class I Zone 2 AEx nA IIC T4 Gc Ta -20°C to +55°C 

Zone 22 AEx tc IIIC T85°C Dc Ta -20°C to +55°C 

 
Installation must be carried out in compliance with the 

National Electric Code. 

 

2.3 CEC Class / Zone ratings Canada 

 

The E2xS2 alarm horn complies with the following standards: 

 

CAN/CSA C22.2 No. 60079-0:2015 
CAN/CSA C22.2 No. 60079-15:2016 

CAN/CSA C22.2 No. 60079-31:2015 

 

The E2XS2 Alarm horn is rated as follows: 
 

Ex nA IIC T4 Gc Ta -20°C to +55°C 

Ex tc IIIC T85°C Dc Ta -20°C to +55°C 

 
Installation must be carried out in compliance with the 

Canadian Electric Code 

 

2.4 NEC & CEC Class / Division Ratings for US / Canada

 

 

The E2xS2 alarm horn complies with the following standards: 

 

ANSI/ISA 12.12.01-2015 

CSA C22.2 No. 213-16 

 

The E2XS2 Alarm horn is rated as follows: 

 

Class I, Div 2,  

ABCD   T3C Ta -20°C to +55°C 

Class I, Div 2,  

ABCD   T4 Ta -20°C to +40°C 

Class II, Div 2,   FG  

T6 Ta -20°C to +55°C 

Class III   

 

T6 Ta -20°C to +55°C 

 
Installation must be carried out in compliance with the 

National Electric Code / Canadian Electric Code 

 

2.5 Ingress Protection Ratings 

 

The product is rated for ingress Protection as follows: 

 

IP rating per EN60079-0:   

IP64 

 

IP rating per EN60529: 

 

IP66 

 

Type rating per UL50E / NEMA250: 4 / 4X / 13 

  

To maintain the ingress protection rating, the two off cable 

entries must be fitted with suitably rated, certified cable entry 
and/or blanking devices during installation. 

 

 

 
 

 

 

 
 

 

2.6 Electrical Ratings 

 

Part No. 

Voltage 

Current 

E2xS2FDC024 / 

E2xS2RDC024 

24Vdc 

280mA 

E2xS2FDC048 / 

E2xS2RDC048 

48Vdc 

215mA 

E2xS2RAC115 / 

E2xS2RAC115

 

115-120Vac 50/60Hz 

142mA 

E2xS2FAC230 / 

E2xS2RAC230 

220-230Vac 50/60Hz 

76mA 

 

It is important that a suitable power supply is used to run the 

equipment.  The  power  supply  selected  must  have  the 

necessary  capacity  to  provide  the  input  current  to  all  the 
units. 

 

The input current will vary according to the voltage input level 
and  the  frequency  of  the  tone  selected.  The  current  levels 

shown  above  are  for  the  tone  resulting  in  the  max.  current 

draw (tone 1 - 340Hz Continuous). 

 

3)  Special Conditions of Use 

 

When  used  for  a  Group  III  application,  the  surface  of  the 

enclosure  may  store  electrostatic  charge  and  become  a 
source of ignition in applications with a low relative humidity 

<~30% relative humidity where the surface is relatively free of 

surface contamination such as dirt, dust, or oil. 

 
Guidance  on  protection  against  the  risk  of  ignition  due  to 

electrostatic discharge can be found in EN TR50404 and IEC 

TR60079-32. 

 

End  user shall adhere  to  the manufacturer’s installation  and 

instruction  when  performing  housekeeping  to  avoid  the 

potential for hazardous electrostatic charges during cleaning, 
by using a damp cloth. 

 

To  maintain  the  ingress  protection  rating  and  mode  of 

protection, the cable entries must be fitted with suitably rated, 
certified  cable  entry  and/or  blanking  devices  during 

installation.  If  conduit  is  used  for  installation,  seal  conduit 

within 18 inches from the enclosure. 

 
Equipment  with  the  flare  horn  shall  not be  installed  with  the 

flare higher than horizontal (to avoid accumulation of dust). 

 

The equipment incorporates metal parts isolated from earth, 
having capacitance values exceeding the limits permitted in 

the standards of certification. Mounting bracket – 10.33pF. 

 

4)  Location and Mounting

 

 

The location of the sounder should be made with due regard 

to  the  area  over  which  the  warning  signal  must  be  audible. 

They  should  only  be  fixed  to  services  that  can  carry  the 
weight of the unit. 

 

The E2x sounder should be secured to any flat surface using 
the  three  7mm  fixing  holes  on  the  stainless  steel  U  shaped 

mounting bracket.  See  Figure  1.  The  required  angle  can  be 

achieved  by  loosening  the  two  large  bracket  screws  in  the 

side  of  the  unit,  which  allow  adjustment  of  the  sounder  in 
steps  of 18°.  On completion of  the installation  the  two  large 

bracket  adjustment  screws  on  the  side  of  the  unit  must  be 

fully tightened to ensure that the unit cannot move in service. 