3.2 

Class/Division & Class Zone Ratings for US & Canada 

 

Class Division Ratings for US (NEC) & Canada (CEC) 

Standards:

 

UL 121201-2021 Edition 9 
CAN/CSA C22.2 No. 213-17 Edition 3 

Model No: 

Rating 

D2xS2FDC024 

D2xS2HDC024 

Class I,  Div 2 ABCD T3C Ta -55°C to +85°C 
Class I,  Div 2 ABCD T4    Ta -55°C to +60°C 
Class I,  Div 2 ABCD T4A  Ta -55°C to +45°C 
Class II, Div 2 FG      T4     Ta -55°C to +85°C 
Class III    

       Ta -55°C to +85°C 

D2xS2FAC230 

D2xS2HAC230 

Class I,  Div 2 ABCD T4   Ta -55°C to +85°C 
Class I,  Div 2 ABCD T4A Ta -55°C to +75°C 
Class I,  Div 2 ABCD T5    Ta -55°C to +55°C 
Class I,  Div 2 ABCD T6    Ta -55°C to +40°C 
Class II, Div 2 FG      T4    Ta -55°C to +85°C 
Class III  

 

      Ta -55°C to +85°C 

Class Zone Ratings for US (NEC)

 

Standards:

 

UL 60079-0 Edition 7 
UL 60079-7 Edition 5 
UL 60079-31 Edition 2 

Model No:

 

Rating

 

D2xS2FDC024 

D2xS2HDC024 

Class I Zone 2 AEx ec IIC T3 Gc Ta -55°C to +75°C 
Class I Zone 2 AEx ec IIC T4 Gc Ta -55°C to +50°C 
Zone 22 AEx tc IIIC T95°C Dc Ta -55°C to +75°C 

D2xS2FAC230 

D2xS2HAC230 

Class I Zone 2 AEx ec IIC T4 Gc Ta -55°C to +75°C 
Class I Zone 2 AEx ec IIC T5 Gc Ta -55°C to +50°C 
Zone 22 AEx tc IIIC T93°C Dc Ta -55°C to +75°C 

Class Zone Ratings for Canada (CEC)

 

Standards:

 

CAN/CSA C22.2 No. 60079-0 Edition 4 
CAN/CSA C22.2 No. 60079-7 Edition 2 
CAN/CSA C22.2 No. 60079-31 Edition 2

 

Model No:

 

Rating

 

D2xS2FDC024 

D2xS2HDC024 

Ex ec IIC T3 Gc Ta -55°C to +75°C 
Ex ec IIC T4 Gc Ta -55°C to +55°C 
Ex tc IIIC T95°C Dc Ta -55°C to +75°C 

D2xS2FAC230 

D2xS2HAC230 

Ex ec IIC T4 Gc Ta -55°C to +75°C 
Ex ec IIC T5 Gc Ta -55°C to +50°C 
Ex tc IIIC T93°C Dc Ta -55°C to +75°C 

Installation must be carried out in compliance with the National 
Electric Code / Canadian Electric Code 

 
3.3 

ATEX / IECEx & UKEx Ratings 

 

Standards 

EN IEC 60079-0:2018 / IEC 60079-0:2017 Edition 7 
EN IEC 60079-7:2015 +A1:2018 / IEC 60079-7:2018 Edition 5.1 
EN 60079-31:2014 / IEC 60079-31:2022, Edition 3

 

Model No: 

Rating 

D2xS2FDC024 
D2xS2HDC024 

Ex ec IIC T3 Gc Ta -55°C to +75°C 
Ex ec IIC T4 Gc Ta -55°C to +55°C 
Ex tc IIIC T95°C Dc Ta -55°C to +75°C 

D2xS2FAC230 
D2xS2HAC230 

Ex ec IIC T4 Gc Ta -55°C to +75°C 
Ex ec IIC T5 Gc Ta -55°C to +50°C 
Ex tc IIIC T93°C Dc Ta -55°C to +75°C 

See Product table for electrical ratings of each unit model

 

Certificate No.    

DEMKO  14ATEX4786493904X  
IECEx ULD 14.0004X 
UKEx UL UL21UKEX2131X      
 

        

Epsilon x 
Equipment Group 
and Category: 
 
 

 

II 3G 
II 3D

 

CE Marking and 
Notified Body No.

 

 

UKCA Marking and 
Notified Body No. 

 

 

 
4)  Zones, Gas Group, Category and 

Temperature Classification 

 

The units can be installed in locations with the following conditions: 

 

Area Classification Gas 

Zone 2 

Explosive gas air mixture not likely to occur in 
normal operation, and if it does, it will only exist for 
a short time. 

Gas Groupings 

Group IIA 

Propane 

Group IIB 

Ethylene 

Group IIC 

Hydrogen and Acetylene 

Temperature Classification for Gas Applications 

T1 

450

o

 C  

T2 

300

o

 C 

T3 

200

o

 C 

T4 

135

o

 C (DC models limited to 55°C) 

T5 

100

o

 C (AC models only to 50°C) 

Area Classification Dust 

Zone 22 

Explosive dust air mixture not likely to occur in 
normal operation, and if it does, it will only exist for 
a short time. 

Dust Groupings 

Group IIIA 

Combustible Dusts 

Group IIIB 

Non-Conductive Dusts 

Group IIIC 

Conductive Dusts 

Equipment Category 

3G, 3D

 

Equipment Protection Level 

 Gc, Dc

 

Maximum Surface Temperature for Dust Applications 

95°C DC Models 
93°C AC Models 

Ambient Temperature Range 

-55°C to +75°C (-67°F to +167°F)  

IP Rating 

IP66/67 to EN60529 
4 / 4X / 3R / 13 to UL50E / NEMA250 

Installation must be carried out in compliance with the latest issue 
of the following standards: 
  
EN60079-14  /  IEC60079-14:  Explosive  atmospheres  -  Electrical 
installations design, selection and erection 
EN60079-10-1  /  IEC60079-10-1:  Explosive  atmospheres  - 
Classification of areas. Explosive gas atmospheres 
EN60079-10-2  /  IEC60079-10-2:  Explosive  atmospheres  - 
Classification of areas. Explosive dust atmospheres 

 
 
 

Summary of Contents for D2xS2F Series

Page 1: ...above are for the 440Hz Continuous tone nominal input voltage Nominal current at nominal voltage Table 1 Electrical Ratings 2 Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN W...

Page 2: ...ition 7 EN IEC 60079 7 2015 A1 2018 IEC 60079 7 2018 Edition 5 1 EN 60079 31 2014 IEC 60079 31 2022 Edition 3 Model No Rating D2xS2FDC024 D2xS2HDC024 Ex ec IIC T3 Gc Ta 55 C to 75 C Ex ec IIC T4 Gc Ta...

Page 3: ...ys be fitted d Replace the cover of the unit taking care not to damage the threads Tighten fully 6 3 Access to the Enclosure Fig 2 Accessing the enclosure To access the chamber loosen the M4 grub scre...

Page 4: ...lands or blanking plugs A minimum ingress protection rating of IP54 must be maintained for installations in explosive gas atmospheres and IP6X must be maintained for installations in explosive dust at...

Page 5: ...e 1 DIP switch setting Following table Table 3 is a summary of DC D252 06 001 AC D252 06 005 wiring options Config Voltage Configuration Description Features Product Option Identifier 1a DC Single Sta...

Page 6: ...duct option V when ordering Spare part code for field installation SP78 0001 Figure 10 End of Line Resistor placement Optional 12 Way Terminal Module 10 Maintenance Overhaul and Repair Maintenance rep...

Page 7: ...with suitably rated cable glands or stopping plugs EOL Monitoring DC Only End of Line Devices may be fitted between the ve ve terminals of the PCBA Please ensure that the device legs meet the wire si...

Page 8: ...4V D2xS2HDC024 A is approved for use as an audible signal appliance for fire alarm use Public Mode UL464 CAN ULC S525 and produces a minimum sound pressure level of P2 US 95 51dB A CA 103 8dB A P3 US...

Page 9: ...1 0 1 0 0 0 0 1 1 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 0 0 1 1 0 1 0 0 0 0 1 1 0 0 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 0 0 1 0 0 1 0 1 1 0 0 1 0 0 0 1 0 1 0 1 0 1 0...

Page 10: ...MONITORING RESISTOR CUSTOMER SUPPLIED 24V MAX SYSTEM 3K9 MIN 0 5W MIN OR 1K MIN 2 0W MIN 48V MAX SYSTEM 15K MIN 0 5W MIN OR 3K9 MIN 2 0W MIN RECOMMENDED MINIMUM VALUES R1 Stage 1 ve IN Stage 1 ve OUT...

Page 11: ...e OUT Stage 1 ve OUT Stage 3 ve Stage 1 ve IN H2 H1 Stage 1 ve Stage 1 ve Stage 2 ve Stage 2 ve OF 2 3 R1 S2 S3 R1 S2 R2 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED RECOMMENDED MINIMUM VALUES...

Page 12: ...to Stage 2 ve Stage 2 ve Two Three Stage Voltage Free Activation Configuration Config 5 Customer Set H1 H2 to Negative Switching See Below Power ve ve Stage 1 Connect Stage 1 ve to Common ve Stage 2 C...

Page 13: ...2 A B D252 06 005 R S RAIT B ISARD R N POTTS OF NTS 1 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED 1 Earth Earth Stage 2 Stage 3 Common Live IN Live OUT Neutral IN Neutral OUT Earth Stage 1 Stage 2...

Page 14: ...urance Notification Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 2813 CSA Group Netherlands B V Utrechtseweg 310 6812...

Page 15: ...the components contained within it are free from substances of very high concern Other Standards and Regulations EN 60529 1992 A2 2013 Degrees of protection provided by enclosures IP code enclosure r...

Page 16: ...Assurance Notification Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 0518 Rake Lane Eccleston Chester CH4 9JN UK Quali...

Page 17: ...e components contained within it are free from substances of very high concern Other Standards and Regulations EN 60529 1992 A2 2013 Degrees of protection provided by enclosures IP code enclosure rate...

Page 18: ...Page left Intentionally blank...

Page 19: ...Page left Intentionally blank...

Page 20: ...Page left Intentionally blank...

Reviews: