1600Hz

1400Hz

1s

0.5s

17) Tone Table 

Tone Selection

 

– 

To select the required first stage tone set the tone switches 1 to 6 (see Fig 10) to the tone setting shown in the table below. The table also shows 

which 2

nd

, 3

rd

 and 4

th

 stage tones are available for use with the selected first stage tone if more than one tone output stage is required.

 

Stage 1 

Tone No 

Tone Description 

Tone Visual 

Switch Settings 

1 2 3 4 5 6

 

Stage 2 

Tone 

(S2) 

Stage 3 

Tone 

(S3) 

Stage 4 

Tone 

(S2 + S3) 

1000Hz PFEER Toxic Gas 

  

0 0 0 0 0 0 

3 2 44 

1200/500Hz @ 1Hz DIN / 
PFEER P.T.A.P. 

  

1 0 0 0 0 0 

1 3 44 

1000Hz @ 0.5Hz(1s on, 1s 
off) PFEER Gen. Alarm 

  

0 1 0 0 0 0 

1 2 44 

1.4KHz-1.6KHz 1s, 1.6KHz-
1.4KHz 0.5s NF C 48-265 

  

1 1 0 0 0 0 

44 24  1 

544Hz(100mS)/440Hz 
(400mS) NF S 32-001 

  

0 0 1 0 0 0 

52 19  1 

1500/500Hz - (0.5s on , 0.5s 
off) x3 + 1s gap AS4428 

  

1 0 1 0 0 0 

7 44 1 

500-1500Hz Sweeping 2 sec 
on 1 sec off AS4428 

  

0 1 1 0 0 0 

6 44 1 

500/1200Hz @ 0.26Hz(3.3s 
on, 0.5s off) Netherlands - 
NEN 2575 

  

1 1 1 0 0 0 

44 24 35 

1000Hz (1s on, 1s off)x7 + (7s 
on, 1s off) IMO Code 1a 

  

  

0 0 0 1 0 0 

18 34  1 

10 

1000Hz (1s on, 1s off)x7 + (7s 
on, 1s off) IMO Code 1a 

1 0 0 1 0 0 

21 34  1 

11 

420Hz(0.5s on, 0.5s off)x3 + 
1s gap ISO 8201 Temporal 
Pattern 

  

0 1 0 1 0 0 

44 1  8 

12 

1000Hz(0.5s on, 0.5s off)x3 + 
1s gap ISO 8201 Temporal 
Pattern 

  

1 1 0 1 0 0 

44 1  8 

13 

422/775Hz  -  (0.85 on, 0.5 
off) x3 + 1s gap NFPA - 
Temporal Coded 

  

0 0 1 1 0 0 

44 1  8 

14 

1000/2000Hz @ 1Hz 
Singapore 

  

1 0 1 1 0 0 

23 3 35 

15 

300Hz Continuous 

  

0 1 1 1 0 0 

44 24 35 

16 

440Hz Continuous 

  

1 1 1 1 0 0 

44 24 35 

17 

470Hz Continuous 

  

0 0 0 0 1 0 

44 24 35 

18 

500Hz Continuous IMO code 
2 (Low) 

  

1 0 0 0 1 0 

44 24 35 

19 

554Hz Continuous 

  

0 1 0 0 1 0 

64 24 35 

20 

660Hz Continuous 

  

1 1 0 0 1 0 

44 24 35 

21 

800Hz IMO code 2 (High) 

  

0 0 1 0 1 0 

44 24 35 

22 

1200Hz Continuous 

  

1 0 1 0 1 0 

44 24 35 

23 

2000Hz Continuous 

  

0 1 1 0 1 0 

15 3 35 

24 

2400Hz Continuous 

  

1 1 1 0 1 0 

48 20 35 

25 

440 @0.83Hz (50 
cycles/minute) Intermittent 

  

0 0 0 1 1 0  

1 44 8 

26 

470 @0.9Hz - 1.1s 
Intermittent 

  

1 0 0 1 1 0 

1 44 8 

27 

470Hz @5Hz - (5 
cycles/second) Intermittent 

  

0 1 0 1 1 0 

1 44 8 

28 

544Hz @ 1.14Hz - 0.875s 
Intermittent 

  

1 1 0 1 1 0 

44 24  8 

29 

655Hz @ 0.875Hz 
Intermittent 

  

0 0 1 1 1 0 

1 44 8 

30 

660Hz @0.28Hz - 1.8sec on, 
1.8sec off Intermittent 

  

1 0 1 1 1 0 

44 24  8 

31 

660Hz @3.34Hz - 150mS on, 
150mS off

 Intermittent

 

  

0 1 1 1 1 0 

30 24  8 

1000Hz

 

1000Hz

1s

1s

544Hz

440Hz

0.1s

0.4s

1500Hz

500Hz

0.5s 0.5s

1.5s

0.5s 0.5s 0.5s

1500Hz

500Hz

2s

1s

1200Hz

500Hz

3.3s

0.5s

1s

1s

1s

7s

7s

1s

1s

1s

1s

1s

1s

1s

1000Hz 1s

1s

1s

1s

0.5s

0.5s

0.5s

1.5s

420Hz 0.5s

0.5s

1000Hz 0.5s

0.5s

0.5s

0.5s

0.5s

1.5s

775Hz

422Hz

0.85s

0.5s

0.85s

0.5s

0.85s

1.5s

2000Hz

1000Hz

1s

300Hz

 

440Hz

 

470Hz

 

500Hz

 

554Hz

 

660Hz

 

800Hz

 

1200Hz

 

2000Hz

 

2400Hz

 

440Hz

0.6s

0.6s

470Hz 0.55s

0.55s

470Hz 0.1s

0.1s

470Hz 0.43s

0.44s

655Hz 0.57s

0.57s

660Hz 1.8s

1.8s

660Hz 0.15s

0.15s

500Hz

1s

1200Hz

Summary of Contents for D2 C2X05DC024 Series

Page 1: ...e the temporal pattern tone No 12 as per the tone table provided in these instructions must be selected This tone produces a minimum sound pressure level of CAN ULC S525 100 4dB A at 10 feet anechoic...

Page 2: ...4 ATEX 4786493904X IECEx ULD 14 0004X The D2xC2X05DC024 Combined unit is rated as follows The D2xC2X10DC024 Combined unit is rated as follows The D2xC2X05DC048 D2xC2X05AC Combined units are rated as f...

Page 3: ...g housekeeping to avoid the potential for hazardous electrostatic charges during cleaning by using a damp cloth To maintain the ingress protection rating and mode of protection the cable entries must...

Page 4: ...he terminals great care should be taken to dress the wires so that when the cover is inserted into the chamber the wires do not exert excess pressure on the terminal blocks This is particularly import...

Page 5: ...l in size and rating to the incoming power conductors The internal earth bonding wire connects the PCBA earth terminal to the internal earth terminal in the enclosure back box External earth connectio...

Page 6: ...hers using a screwdriver Remove the wire guard and replace the old lens cover with the new lens cover Fig 11 Replacement of beacon lens cover Fit the wire guard back onto the housing over the new lens...

Page 7: ...208 740 4200 Document No D211 00 601 IS SC Issue F 02 03 2020 Sheet 7 of 9 16 Sound Directional Characteristics for Canadian Fire CAN ULC S525 Horizontal Axis Vertical Axis Angle OSPL Angle OSPL Refer...

Page 8: ...0 5s off x3 1s gap ISO 8201 Temporal Pattern 0 1 0 1 0 0 44 1 8 12 1000Hz 0 5s on 0 5s off x3 1s gap ISO 8201 Temporal Pattern 1 1 0 1 0 0 44 1 8 13 422 775Hz 0 85 on 0 5 off x3 1s gap NFPA Temporal C...

Page 9: ...44 24 12 49 560 1055Hz 0 18Hz Sweeping 0 0 0 0 1 1 44 24 12 50 560 1055Hz 3 3Hz Sweeping 1 0 0 0 1 1 44 24 12 51 600 1250Hz 0 125Hz Sweeping 0 1 0 0 1 1 44 24 12 52 660 1200Hz 1Hz Sweeping 1 1 0 0 1...

Reviews: