E2S D1 B2LD2 Series Instruction Manual Download Page 6

 

E2S Warning Signals

      Impress House, Mansell Road, Acton, London W3 7QH

www.e2s.com

 

Tel: +44 (0)208 743 8880

Document No. D191-00-401-IS

 

Issue 3

 

28-11-22

Sheet 6 of 6

 

12) Maintenance, Overhaul & Repair 

 

Maintenance,  repair  and  overhaul  of  the  equipment  should 
only  be  carried  out  by  suitably  qualified  personnel  in 
accordance with the current relevant standards: 

 

EN60079-19 / IEC60079-19 Explosive atmospheres - 
Equipment repair, overhaul and reclamation 
 
EN 60079-17 / IEC60079-17 Explosive atmospheres - 
Electrical installations inspection and maintenance 

 

To  avoid  a  possible  ELECTROSTACTIC  CHARGE  the  unit 
must only be cleaned with a damp cloth. 

 

Units must not be opened while an explosive atmosphere is 
present. 

 

If  opening  the  unit  during  maintenance  operations  a  clean 
environment must be maintained and any dust layer removed  
 
Flameproof joints are not intended to be repaired. 
 

13) Interchangeable & Spare Parts 

 

 

 
The Beacon lens cover is interchangeable, contact E2S Ltd for 
a replacement lens cover available in various colours. 
 
To change the lens cover, unscrew the 4-off M5 socket head 
screws,  spring  and  flat  washers  using  a  4mm  Hex  key. 
Remove the wire guard and replace the old lens cover with the 
new lens cover. 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Fig. 10 Replacement of beacon lens cover 

 
Fit the wire guard back onto the housing, over the new lens 
cover  aligning  the  fixing  holes  of  the  guard,  lens  cover  and 
housing. Refit the fixings to hold into place, the fixings MUST 
be fitted in the order shown above. 
 
 
 
 
 
 
 
 
 
 
 
 
 

14) SIL 2 Reliability Data 

 

Reliability and Functional safety IEC/EN61508 which has 
been assessed and is considered suitable for use in low 
demand safety function: 
 
1.  Random Hardware Failures and Architectural constraints 

(route 

2

H

). 

2.  As an unvoted item (i.e. hardware fault tolerance of 0) at 

SIL 2. 

The product was assessed against failure modes: 

 

Failure respond to an input by lighting a beacon. 

 

Spurious light output despite no input.

 

3.

 

When employing the device in a SIL2 compliant system 
the user should ensure frequent or continuous automatic 
monitoring of continuity. 
 

 

Integrity in respect of failure to 

function

 

SIL2

& SIL1

 

Total Failure rate 

0.

48

 pmh 

“Hazardous” failure rate (revealed) 

0

 pmh 

“Hazardous” failure rate (unrevealed) 

0.

48

 pmh 

“Safe” failure rate (revealed) 

0 pmh 

“Safe” failure rate (unrevealed) 

0

System type

B

Hardware Fault Tolerance 

0

Diagnostic Coverage

 

>

60

PFD (hazardous failure) 

2.1

 x 10

-

3

 

Proof Test Interval 

Up to 1 year 

 
 

Warning –

 

Hot surfaces. External surfaces 

and internal components may be hot after 
operation, take care when handling the 
equipment. 

M5 screw 
M5 spring washer 
M5 flat washer 

Summary of Contents for D1 B2LD2 Series

Page 1: ...R UNIQUEMENT AVEC UN CHIFFON HUMIDE NE PAS PEINTURER POUR R DUIRE LE RISQUE D INFLAMMATION DES ATMOSPH RES DANGEREUSES LE PREMIER CONDUIT DE CONDUIT DOIVENT AVOIR UN RACCORD D TANCH IT RACCORD MOINS D...

Page 2: ...units the certification approval has validated continuous use up to 38 C ambient and are for transient use up to 80 C ambient Certificate No DEMKO 19 ATEX 2009X IECEx ULD 19 0006X UL21UKEX2130X ATEX M...

Page 3: ...sification of areas Explosive gas atmospheres EN60079 10 2 IEC60079 10 2 Explosive atmospheres Classification of areas Explosive dust atmospheres The installation of the units must also be in accordan...

Page 4: ...s or blanking plugs For use in explosive dust atmospheres a minimum ingress protection rating of IP6X must be maintained For use in explosive gas atmospheres a minimum ingress protection rating of IP5...

Page 5: ...000001 Steady Low Power Flashing 1Hz Flashing Triple Strike 100000 Flashing 1Hz Flashing Double Strike Flashing Triple Strike 101000 Flashing 1 5Hz Flashing 2Hz Flashing Double Strike 010000 Flashing...

Page 6: ...h the new lens cover Fig 10 Replacement of beacon lens cover Fit the wire guard back onto the housing over the new lens cover aligning the fixing holes of the guard lens cover and housing Refit the fi...

Page 7: ...Page left Intentionally blank...

Page 8: ...AR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT...

Page 9: ...Page left Intentionally blank...

Page 10: ...Gb II 2D Ex tb IIIC T95 C T169 C Db Standards applied EN 60079 0 2018 EN 60079 1 2014 EN 60079 31 2014 IP6X Dust Protection to EN60079 0 EN60079 31 Directive 2014 30 EU Electromagnetic Compatibility...

Page 11: ...Ex d IIC T6 T3 Gb II 2D Ex tb IIIC T95 C T169 C Db Standards applied EN 60079 0 2018 EN 60079 1 2014 EN 60079 31 2014 IP6X Dust Protection to EN60079 0 EN60079 31 Directive 2014 30 EU Electromagnetic...

Page 12: ...Page left Intentionally blank...

Reviews: