background image

 
 
 
 
 
 

 

E2S

 

Telephone:

 

+44

 

(0)20

 

8743

 

8880

 

Fax:

 

+44

 

(0)20

 

8740

 

4200

 

Email:

 

[email protected]

 

www.e2s.com

 

DC

005_Issue_P

 

(BExCS).docxN

 ‐ 

Page

 

1

 

of

 

2

 ‐ 

QAF_252_Issue_5

 

EU

 

Declaration

 

of

 

Conformity

 

Manufacturer:

   

 

European

 

Safety

 

Systems

 

Ltd.

 

 

 

 

Impress

 

House,

 

Mansell

 

Road,

 

Acton

 

 

 

 

London,

 

W3

 

7QH

 

 

 

 

United

 

Kingdom

 

 

Authorised

 

Representative:

 

E2S

 

Warnsignaltechnik

 

UG

 

 

 

 

Charlottenstrasse

 

45

51

 

 

 

 

72764

 

Reutlingen

 

 

 

 

Germany

 

 

Equipment

 

Type:

  

 

BExCS110

05D,

 

BExDCS110

05D,

 

BExCS110

05D

R,

 

BExDCS110

05D

R,

 

 

 

 

BExCS110

05D

P,

 

BExDCS110

05D

P,

 

BExCS110

05D

R

P,

 

BExDCS110

05D

R

P,

 

 

 

 

BExCL15

05D,

 

BExDCL15

05D,

 

BExCL15

05D

R,

 

BExDCL15

05D

R,

 

 

 

 

BExCL15

05D

P,

 

BExDCL15

05D

P,

 

BExCL15

05D

R

P,

 

BExDCL15

05D

R

P,

 

 

 

 

BExCTS110

05D,

 

BExDCTS110

05D,

 

BExCTS110

05D

R,

 

BExDCTS110

05D

R,

 

 

 

 

BExCTS110

05D

P,

 

BExDCTS110

05D

P,

 

BExCTS110

05D

R

P,

 

BExDCTS110

05D

R

P,

 

 

 

 

BExCS110

L1D,

 

BExDCS110

L1D,

 

BExCS110

L1D

R,

 

BExDCS110

L1D

R

 

 

 

 

BExCS110

L2D,

 

BExCS110

L2D

R,

 

BExCA110

05D

P

 

 

Directive

 

2014/34/EU:

 

Equipment

 

and

 

Protective

 

Systems

 

for

 

use

 

in

 

Potentially

 

Explosive

 

Atmospheres

 

(ATEX)

 

Notified

 

Body

 

for

 

EU

 

type

 

Examination

 

(Module

 

B):

 

Dekra

 

Certification

 

B.V.

 

Notified

 

Body

 

No.:

 

0344

 

Meander

 

1051,

 

6825

 

MJ

 

Arnhem,

 

The

 

Netherlands

 

EU

type

 

Examination

 

Certificate

 

(Module

 

B):

 

KEMA

 

01ATEX2223X

 

Notified

 

Body

 

for

 

Quality

 

Assurance

 

Notification

 

/

 

Conformity

 

to

 

EU

type

 

based

 

on

 

quality

 

assurance

 

of

 

the

 

production

 

process

 

(Module

 

D):

 

Sira

 

Certification

 

Service

 

Notified

 

Body

 

No.:

 

2813

 

CSA

 

Group

 

Netherlands

 

B.V,

 

Utrechtseweg

 

310,

 

6812

 

AR,

 

Arnhem,

 

Netherlands

 

Quality

 

Assurance

 

Notification

 

(Module

 

D):

 

SIRA

 

05

 

ATEX

 

M342

 

Provisions

 

fulfilled

 

by

 

the

 

equipment:

 

II

 

2G

 

Ex

 

db

 

IIB

 

T5

 

or

 

T4

 

Gb

 

II

 

2D

 

Ex

 

tb

 

IIIC

 

T70°C

 

to

 

T125°C

 

Db

 

IP6X

 

Dust

 

Protection

 

to

 

EN60079

0

 

/

 

EN60079

31

 

Standards

 

applied:

 

EN

 

60079

0:2012

 

+

 

A11:2013

 

/

 

EN

 

IEC

 

60079

0:

 

2018

 

EN

 

60079

1:2014

 

EN

 

60079

31:2014

 

IP6X

 

Dust

 

Protection

 

to

 

EN60079

0

 

/

 

EN60079

31

 

Directive

 

2014/30/EU:

 

Electromagnetic

 

Compatibility

 

Directive

 

(EMC)

  

Standards

 

applied:

 

EN

 

61000

6

1:2007

 

EN

 

61000

6

2:2005

 

EN

 

61000

6

3:2007

 

/

 

A1:2011

 

/

 

AC:

 

2012

 

EN

 

61000

6

4:2007

 

/

 

A1:

 

2011

 

Directive

 

2011/65/EU:

 

Restriction

 

of

 

the

 

use

 

of

 

certain

 

hazardous

 

substances

 

in

 

electrical

 

and

 

electronic

 

equipment

 

(RoHS)

 

The

 

product

 

and

 

all

 

the

 

components

 

contained

 

within

 

it

 

are

 

in

 

accordance

 

with

 

the

 

restriction

 

of

 

the

 

use

 

of

 

hazardous

 

substances

 

in

 

electrical

 

and

 

electronic

 

equipment,

 

including

 

amendment

 

Directive

 

2015/863/EU.

 

Regulation

 

(EC)

 

1907/2006:

 

Registration,

 

Evaluation,

 

Authorisation

 

and

 

Restriction

 

of

 

Chemicals

 

(REACH)

 

The

 

product

 

and

 

all

 

the

 

components

 

contained

 

within

 

it

 

are

 

free

 

from

 

substances

 

of

 

very

 

high

 

concern.

 

Other

 

Standards

 

and

 

Regulations

 

 

EN

 

60529:1991

 

+

 

A1:2000

 

+

 

A2:2013.

 ‐ 

Degrees

 

of

 

protection

 

provided

 

by

 

enclosures

 

(IP

 

code)

 

 

enclosure

 

rated

 

IP66/67

 

 

Summary of Contents for BExCS110-05

Page 1: ...05DPAC230 BExCS110 05DPAC230 R 230Vac 56mA 55mA 253V Max Tone 4 Nom Tone 44 The table shows the input current taken by the various units The current levels shown above are for the 440Hz Continuous to...

Page 2: ...air mixture not likely to occur in normal operation and if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Temperature Classification for Gas Application...

Page 3: ...it cannot move in service Fig 1a Fixing Location for Combined Flare Fig 1b Fixing Location for Combined Radial 7 Access to the Flameproof Enclosure To access the Ex d chamber remove the four M6 hexago...

Page 4: ...section of the unit Fig 3 Internal View of Cover When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the incoming earth wire and the enclosure Internal ear...

Page 5: ...m power rating of 0 5 watts or a minimum resistance value of 500 and a minimum power rating of 2 watts The resistor must be connected directly across the ve and ve terminals as shown in the following...

Page 6: ...sounder on stage one simply connect the supply voltage to the normal supply terminals ve and ve for DC units L and N for AC units Refer to wiring schematics D210 06 601 DC or D210 06 605 AC Default To...

Page 7: ...Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards EN60079 19 IEC60079 19 Explosive at...

Page 8: ...mittent 660Hz 1 8s on 1 8s off 1 0 0 0 1 0 2 5 19 1400Hz to 1600Hz sweeep up over 1s 0 1 0 0 1 0 2 5 1600Hz to 1400Hz sweep down over 0 5s 20 Continuous 660Hz 1 1 0 0 1 0 2 5 21 Alternating 554 440Hz...

Page 9: ...Page left Intentionally blank...

Page 10: ...ER SUPPLIED 500 MIN 2W MIN OR 3K3 MIN 0 5W MIN MINIMUM VALUES R1 Single Stage Configuration Config 1a Line Monitoring Set to negative switching default Stage 1 Apply Power to Stage 1 ve Stage 1 ve Two...

Page 11: ...RFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D210 06 605 R S RAIT B...

Page 12: ...cation Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 2813 CSA Group Netherlands B V Utrechtseweg 310 6812 AR Arnhem Ne...

Page 13: ...te and Place of Issue London 21 05 2020 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the...

Page 14: ...X2639X Notified Body for Quality Assurance Notification Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 0518 Rake Lane E...

Page 15: ...nd Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the ma...

Page 16: ...Page left Intentionally blank...

Reviews: