14.  Interchangeable & Spare Parts 

 

 

The  beacon  cover  is  interchangeable,  contact  E2S  Ltd  for  a 
replacement cover available in various colours.  

 

To change the cover, unscrew the M5 socket head screws and 
remove  the  M5  screws,  M5  spring  &  flat  washers. 

 

Fig. 8 Removal of cover 

 

Remove  the  guard  and  replace  the  old  cover  with  the  new 
cover.  

 

Fig. 9 Changing of cover 

Fit the guard back on to the cover and casting, align the holes 
of  the  guard,  cover  and  casting.  To  reattach  the  cover,  the 
fixings MUST be in the order shown in figure 10.    
 

 

Fig. 10 Cover and Guard Fixtures 

 
 

15.  Maintenance, Overhaul & Repair 

 

Maintenance,  repair  and  overhaul  of  the  equipment  should 
only  be  carried  out  by  suitably  qualified  personnel  in 
accordance with the current relevant standards: 

 

EN60079-19 
IEC60079-19 

Explosive atmospheres - Equipment 
repair, overhaul and reclamation 

 

EN 60079-17 
IEC60079-17 

Explosive atmospheres - Electrical 
installations inspection and maintenance 

 

To  avoid  a  possible  ELECTROSTACTIC  CHARGE  the  unit 
must only be cleaned with a damp cloth. 

 

Units must not be opened while an explosive atmosphere is 
present. 

 

If  opening  the  unit  during  maintenance  operations  a  clean 
environment must be maintained and any dust layer removed 
prior to opening the unit. 

 
 
 

 
 
 
 
 
 

 

Warning – Hot surfaces. External surfaces 
and internal components may be hot after 
operation, take care when handling the 
equipment. 

M5x16 Hex Socket Screw 

M5 Spring Washer 

M5 Plain Washer 

Guard 

Cover 

M5x16 Hex 
Socket Screw 

Old 
Cover 

New 
Cover 

Summary of Contents for BExBGL2D-P

Page 1: ...z It is important that a suitable power supply is used to run the equipment The power supply selected must have the necessary capacity to provide the input current to all of the units The above table shows the input current taken by the various beacons and shows the maximum voltage at which the beacons can be operated The input current will vary according to the voltage input level 2 Warnings DO N...

Page 2: ...nd if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Group IIC Hydrogen and Acetylene up to 55 C ambient Temperature Classification for Gas Applications T1 450o C T2 300o C T3 200o C T4 135o C T5 100 C T6 100 C Up to 60 C Ambient Area Classification Dust Zone 21 Explosive dust air mixture likely to occur in normal operation Zone 22 Explosive dust air...

Page 3: ...tation Fig 1 Fixing Location for Beacon 7 Access to the Flameproof Enclosure To access the Ex d chamber remove the four M6 hexagon socket head screws and withdraw the flameproof cover taking extreme care not to damage the flameproof joints in the process M6 cover screws are Class A4 80 stainless steel and only screws of this category can be used for the enclosure Fig 2 Accessing the Explosion proo...

Page 4: ... Cover When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the incoming earth wire and the enclosure Internal earthing connections should be made to the Internal Earth terminal in the base of the housing using a ring crimp terminal to secure the earth conductor under the earth clamp The earth conductor should be at least equal in size and rating to the ...

Page 5: ... and ve terminals as shown in the following drawing The resistor leads should be kept as short as possible Fig 6 End of Line Resistor Placement 13 Flash Rate Settings The BExBGL2D beacons can produce different flash patterns as shown in Table 1 The flash patterns are selected by operation of the flash setting DIP switch on the PCB Fig 9 Fig 7 DIP Switch Location Table 1 Switch Positions for Flash ...

Page 6: ...es 15 Maintenance Overhaul Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards EN60079 19 IEC60079 19 Explosive atmospheres Equipment repair overhaul and reclamation EN 60079 17 IEC60079 17 Explosive atmospheres Electrical installations inspection and maintenance To avoid a possible ELE...

Page 7: ... SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D210 06 401 R S RAIT B ISARD R N POTTS OF NTS 1 1 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 500Ω MIN 2W MIN OR 3K3Ω MIN 0 5W MIN MINIMUM VALUES R1 Single Stage Configuration Config 1 Line Monitoring Stage 1 on...

Page 8: ...CES TO ISO1101 1983 LINEAR DIMENSIONAL TOLS ANGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D210 06 405 R S RAIT B ISARD R N POTTS OF NTS 1 1 AC Configu...

Page 9: ...2813 CSA Group Netherlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment I 2G Ex db IIC T6 T3 Gb II 2G Ex db eb IIC T5 T4 Gb II 2D Ex tb IIIC T60 ºC T200 ºC Db Standards applied EN IEC 60079 0 2018 EN 60079 1 2014 EN 60079 7 2015 A1 2018 EN 60079 31 2014 Directive 2014 30 EU Electromagnetic Compatibil...

Page 10: ... and Place of Issue London 20 04 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the market the equipment conforms with all technical and regulatory requirements of the above listed directives regulations and standards This Declaration is issued under the sole responsibility of the manu...

Page 11: ... Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 2G Ex db IIC T6 T3 Gb II 2G Ex db eb IIC T5 T4 Gb II 2D Ex tb IIIC T60 C T200 Db IP6X Dust Protection to EN60079 0 EN60079 31 Standards applied EN IEC 60079 0 2018 EN 60079 1 2014 EN IEC 60079 7 2015 A1 2018 EN 60079 31 2014 Directive 2014 30 EU Electromagnetic Compa...

Page 12: ...and Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the market the equipment conforms with all technical and regulatory requirements of the above listed directives regulations and standards This Declaration is issued under the sole responsibility of the man...