DC-004_Issue_N (BExBG) - Page 1 of 2 - QAF_252_Issue_5

 

EU Declaration of Conformity 

Manufacturer:   

 

European Safety Systems Ltd. 

 

 

 

Impress House, Mansell Road, Acton 

 

 

 

London, W3 7QH 

 

 

 

United Kingdom 

 
Authorised Representative: 

E2S Warnsignaltechnik UG 

 

 

 

Charlottenstrasse 45-51 

 

 

 

72764 Reutlingen 

 

 

 

Germany 

 
Equipment Type:  

 

Electronic Beacons 
Types BExBG05D(-P)(-SIL), BExBG10D(-P)(-SIL), BExBG15D(-P)(-SIL), BExBG21D(-P), 
BExTBG05D(-P), BExBGL2D(-P), BExBG05E(-P), BExBG10E(-P) and BExBG15E(-P)

 

Directive 2014/34/EU: Equipment and Protective Systems for use in Potentially Explosive Atmospheres (ATEX) 

Notified Body for EU type Examination (Module B): 

Dekra Certification B.V. 
Notified Body No.: 0344 
Meander 1051, 6825 MJ Arnhem, The Netherlands 

EU-type Examination Certificate (Module B): 

KEMA 00ATEX2006X 

Notified Body for Quality Assurance Notification / Conformity to EU-type 
based on 
quality assurance of the production process (Module D): 

Sira Certification Service 
Notified Body No.: 2813 
CSA Group Netherlands B.V, Utrechtseweg 310, 6812 AR, Arnhem, Netherlands 

Quality Assurance Notification (Module D): 

SIRA 05 ATEX M342 

Provisions fulfilled by the equipment: 

I 2G Ex db IIC T6...T3 Gb 
II 2G Ex db eb IIC T5...T4 Gb 
II 2D Ex tb IIIC T60 ºC...T200 ºC Db

 

Standards applied: 

EN IEC 60079-0 : 2018 
EN 60079-1 : 2014 
EN 60079-7 : 2015 + A1 : 2018 
EN 60079-31 : 2014

 

Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC)  

Standards applied: 

EN 61000-6-1:2007 
EN 61000-6-2:2005 
EN 61000-6-3:2007 / A1:2011 / AC: 2012 
EN 61000-6-4:2007 / A1: 2011 

Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) 

The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and electronic 
equipment, including amendment by Directive 2015/863/EU.

 

Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) 

The product and all the components contained within it are free from substances of very high concern. 

Other Standards and Regulations 

EN 60529:1991 + A1:2000 + A2:2013. - Degrees of protection provided by enclosures (IP code) 

 enclosure rated IP66/67 

 

 

Summary of Contents for BExBGL2D-P

Page 1: ...z It is important that a suitable power supply is used to run the equipment The power supply selected must have the necessary capacity to provide the input current to all of the units The above table shows the input current taken by the various beacons and shows the maximum voltage at which the beacons can be operated The input current will vary according to the voltage input level 2 Warnings DO N...

Page 2: ...nd if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Group IIC Hydrogen and Acetylene up to 55 C ambient Temperature Classification for Gas Applications T1 450o C T2 300o C T3 200o C T4 135o C T5 100 C T6 100 C Up to 60 C Ambient Area Classification Dust Zone 21 Explosive dust air mixture likely to occur in normal operation Zone 22 Explosive dust air...

Page 3: ...tation Fig 1 Fixing Location for Beacon 7 Access to the Flameproof Enclosure To access the Ex d chamber remove the four M6 hexagon socket head screws and withdraw the flameproof cover taking extreme care not to damage the flameproof joints in the process M6 cover screws are Class A4 80 stainless steel and only screws of this category can be used for the enclosure Fig 2 Accessing the Explosion proo...

Page 4: ... Cover When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the incoming earth wire and the enclosure Internal earthing connections should be made to the Internal Earth terminal in the base of the housing using a ring crimp terminal to secure the earth conductor under the earth clamp The earth conductor should be at least equal in size and rating to the ...

Page 5: ... and ve terminals as shown in the following drawing The resistor leads should be kept as short as possible Fig 6 End of Line Resistor Placement 13 Flash Rate Settings The BExBGL2D beacons can produce different flash patterns as shown in Table 1 The flash patterns are selected by operation of the flash setting DIP switch on the PCB Fig 9 Fig 7 DIP Switch Location Table 1 Switch Positions for Flash ...

Page 6: ...es 15 Maintenance Overhaul Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards EN60079 19 IEC60079 19 Explosive atmospheres Equipment repair overhaul and reclamation EN 60079 17 IEC60079 17 Explosive atmospheres Electrical installations inspection and maintenance To avoid a possible ELE...

Page 7: ... SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D210 06 401 R S RAIT B ISARD R N POTTS OF NTS 1 1 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 500Ω MIN 2W MIN OR 3K3Ω MIN 0 5W MIN MINIMUM VALUES R1 Single Stage Configuration Config 1 Line Monitoring Stage 1 on...

Page 8: ...CES TO ISO1101 1983 LINEAR DIMENSIONAL TOLS ANGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D210 06 405 R S RAIT B ISARD R N POTTS OF NTS 1 1 AC Configu...

Page 9: ...2813 CSA Group Netherlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment I 2G Ex db IIC T6 T3 Gb II 2G Ex db eb IIC T5 T4 Gb II 2D Ex tb IIIC T60 ºC T200 ºC Db Standards applied EN IEC 60079 0 2018 EN 60079 1 2014 EN 60079 7 2015 A1 2018 EN 60079 31 2014 Directive 2014 30 EU Electromagnetic Compatibil...

Page 10: ... and Place of Issue London 20 04 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the market the equipment conforms with all technical and regulatory requirements of the above listed directives regulations and standards This Declaration is issued under the sole responsibility of the manu...

Page 11: ... Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 2G Ex db IIC T6 T3 Gb II 2G Ex db eb IIC T5 T4 Gb II 2D Ex tb IIIC T60 C T200 Db IP6X Dust Protection to EN60079 0 EN60079 31 Standards applied EN IEC 60079 0 2018 EN 60079 1 2014 EN IEC 60079 7 2015 A1 2018 EN 60079 31 2014 Directive 2014 30 EU Electromagnetic Compa...

Page 12: ...and Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the market the equipment conforms with all technical and regulatory requirements of the above listed directives regulations and standards This Declaration is issued under the sole responsibility of the man...

Reviews: