E2S BExBG10D-P-SIL Instruction Manual Download Page 18

 
 
 
 
 
 

 

E2S

 Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: [email protected] 

www.e2s.com 

DC-065_Issue_D (BExBG SIL2) - Page 1 of 1 - QAF_252_Issue_5

 

 
 
 

Martin Streetz 

Document No.: 

DC-065_Issue_D 

Quality Assurance Manager 

Date and Place of Issue: 

London, 08/09/2016 

EU Declaration of Conformity 

Manufacturer:  European Safety Systems Ltd. 
 

Impress House, Mansell Road, Acton 

 

London, W3 7QH, United Kingdom 

 
Equipment Type: 

BExBG05D-SIL, BExBG10D-SIL, BExBG15D-SIL 

 

BExBG05D-P-SIL, BExBG10D-P-SIL, BExBG15D-P-SIL 

 

Directive 2014/34/EU: Equipment and Protective Systems for use in Potentially Explosive Atmospheres (ATEX) 

Notified Body for EU type Examination (Module B): 

Dekra Certification B.V. 
Notified Body No.: 0344 
Meander 1051, 6825 MJ Arnhem, The Netherlands 

EU-type Examination Certificate (Module B): 

KEMA 00ATEX2006X 

Notified Body for Quality Assurance Notification / Conformity to 
EU-type based on 
quality assurance of the production process (Module D): 

Sira Certification Service 
Notified Body No.: 0518 
Rake Lane, Eccleston, Chester CH4 9JN, UK 

Quality Assurance Notification (Module D): 

SIRA 05 ATEX M342 

Provisions fulfilled by the equipment: 

II 2G Ex d llC T4 to T6 Gb 
II 2D Ex tb IIIC T85°C to T125°C Db 
IP6X Dust Protection to EN60079-0 / EN60079-31 

Standards applied: 

EN 60079-0:2012 + A11:2013 
EN 60079-1:2007 
EN 60079-31:2014 

Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC)  

Standards applied: 

EN 61000-6-1:2007 
EN 61000-6-2:2005 
EN 61000-6-3:2007 / A1:2011 / AC: 2012 
EN 61000-6-4:2007 / A1: 2011 

Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) 

The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and 
electronic equipment. 

Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) 

The product and all the components contained within it are free from substances of very high concern. 

Other Standards and Regulations 

Safety Integrity Level: 

 

suitable for 

SIL2

 (for product software and hardware) 

System Capability:  

 

suitable for 

SC=2

 (for product software and hardware) 

System Capability assessment: 

1s 

(by cross-functional team assessment) 

IEC 61508-1 (2010) Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements 
IEC 61508-2 (2010) Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for 
electrical/electronic/programmable electronic safety-related systems 
IEC 61508-3 (2010) Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements 
EN 60529:1991 + A1:200 + A2:2013 - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66/67 

 

On behalf of European Safety Systems Ltd., I declare that, on the date the equipment accompanied by this declaration is placed on the market, the 
equipment conforms with all technical and regulatory requirements of the above listed directives, regulations and  standards. 
 
This Declaration is issued under the sole responsibility of the manufacturer. 

Summary of Contents for BExBG10D-P-SIL

Page 1: ...EX2006X IECEx KEM 10 0002X The BExBG10D and BExBG15D beacons have been certified for use in locations with the following conditions Area Classification Gas Zone 1 Explosive gas atmosphere likely to oc...

Page 2: ...location of the beacons should be made with due regard to the area over which the warning signal must be visible They should only be fixed to services that can carry the weight of the unit SAFETY WAR...

Page 3: ...or use in explosive dust atmospheres a minimum ingress protection rating of IP6X must be maintained The BEx beacon range can be supplied with the following types of adapters M20 to NPT M20 to NPT M20...

Page 4: ...the control panel A fault condition can be communicated via independent fault contacts or by the introduction to the monitoring circuit of an end of line resistor A SIL 2 system wiring for fault dete...

Page 5: ...re and may not be functioning correctly 13 2 Power Failure SIL 2 Failure SIL 2 Controller failure Internal function and system checking flags fault Rapid Power cycling System indicates power instabili...

Page 6: ...be seen via the SIL 2 TB1 terminals as soon as the fault occurs in either Active or Standby modes As factory default when there is no fault the TB1 terminals 1 2 will be closed putting a 3 3k current...

Page 7: ...he default customer sense resistor value is 3 3k Examples of calculations of resistance for steady mode and fault mode are shown in table 1 Panel Resolution Topology Resistor TB1 CSR No of Units Stead...

Page 8: ...units default position is A Figure 7 Schematic of SIL 2 system wiring for fault detection in standby mode only 2 wire installation To evaluate the total current drawn from the SIL 2 unit use the equa...

Page 9: ...e customer can select a system EOL resistor The default fault resistor value is 2 2k which is recommended and is fitted according to the configuration topology chosen Panel Resolution Topology Resisto...

Page 10: ...et 10 of 17 10 14 3 Header Pins Settings Figure 8 J1 Header settings Figure 9 J2 Header settings J1 Header Pin Postion A Factory default position pins 1 2 not linked places TB1 Current sense resistor...

Page 11: ...i e the two header pins are not shorted together see Figure 5 18 Flip Flop Operation Two beacons can be mounted close to each other to form a flip flop operation where the beacons will flash alternat...

Page 12: ...Coding for Fault Resistor and Customer EOL Resistor The customer is able to identify the resistor values chosen on purchase from the product code This is represented by the last two characters BEXBG1...

Page 13: ...n in figure 12 Fig 13 Cover and Guard Fixtures 23 Maintenance Overhaul and Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accorda...

Page 14: ...Safety Systems Ltd Impress House Mansell Road Acton London W3 7QH sales e 2 s com Tel 44 0 208 743 8880 www e 2 s com Fax 44 0 208 740 4200 Document No D197 00 112 IS Issue B 16 06 17 Sheet 14 of 17...

Page 15: ...Safety Systems Ltd Impress House Mansell Road Acton London W3 7QH sales e 2 s com Tel 44 0 208 743 8880 www e 2 s com Fax 44 0 208 740 4200 Document No D197 00 112 IS Issue B 16 06 17 Sheet 15 of 17 1...

Page 16: ...Safety Systems Ltd Impress House Mansell Road Acton London W3 7QH sales e 2 s com Tel 44 0 208 743 8880 www e 2 s com Fax 44 0 208 740 4200 Document No D197 00 112 IS Issue B 16 06 17 Sheet 16 of 17...

Page 17: ...Safety Systems Ltd Impress House Mansell Road Acton London W3 7QH sales e 2 s com Tel 44 0 208 743 8880 www e 2 s com Fax 44 0 208 740 4200 Document No D197 00 112 IS Issue B 16 06 17 Sheet 17 of 17 1...

Page 18: ...2011 Directive 2011 65 EU Restriction of the use of certain hazardous substances in electrical and electronic equipment RoHS The product and all the components contained within it are in accordance wi...

Reviews: