background image

warning signals

2S

BEx

EUROPEAN SAFETY SYSTEMS LTD

IMPRESS HOUSE

MANSELL ROAD

ACTON

LONDON W3 7QH

WWW.E2S.COM

C

THIS DRAWING AND ANY INFORMATION OR DESCRIPTIVE 

MATTER THEREIN IS COMMUNICATED IN CONFIDENCE AND 

IS THE COPYRIGHT PROPERTY OF EUROPEAN SAFETY 

SYSTEMS LTD. NEITHER THE WHOLE OR ANY EXTRACT MAY 

BE DISCLOSED, LOANED, COPIED OR USED FOR 

MANUFACTURING OR TENDERING PURPOSES WITHOUT THEIR 

WRITTEN CONSENT.

EUROPEAN SAFETY SYSTEMS LTD.

AS PER LATEST DATE OF ISSUE SHOWN ABOVE

DRAWING TO BS8888:2000

GEOMETRIC TOLERANCES TO ISO1101:1983

LINEAR DIMENSIONAL TOLS

ANGULAR DIMENSIONAL TOLS

STANDARDS

MOD No.

REASON - INITIAL - DATE

ISSUE

DATE

APPROVED

CHECKED

DATE

DATE

DRAWN

WEIGHT (Kg)

SURFACE FINISH

MATERIAL

ALTERNATIVE MATERIAL

SHEET

SCALE

TITLE

A3

IF IN DOUBT, ASK - 

DO NOT SCALE

ALL DIMENSIONS IN MM

DRAWING NUMBER

A

B

C

D

E

F

G

10

9

G

F

E

7

8

6

5

D

C

1

3

4

2

A

B

D210-06-031

R.S.RAIT

B.ISARD

R.N.POTTS

OF

NTS

1

1

OPTIONAL LINE MONITORING RESISTOR, CUSTOMER SUPPLIED,  

 500Ω MIN, 2W MIN OR 3K3Ω MIN, 0.5W MIN

MINIMUM VALUES:

R1

Single Stage Configuration

                         Config.: 1a

Line Monitoring

Header pins set to negative switching (default)

Stage 1: Apply Power to Stage 1 +ve & Stage 1 -ve

Two/Three Stage Configuration

   Config.: 1b

Common Positive

Header pins set to negative switching (default)

Stage 1:Apply Power to +ve & -ve

Stage 2: Apply Power to +ve & -ve, Connect Stage 2 to -ve

Stage 3: Apply Power to +ve & -ve, Connect Stage 3 to -ve

Stop: Apply Power to +ve & -ve, Connect Stop to -ve

Two/Three Stage Configuration

      Config.: 1c

Common Negative

Set header pins to positive switching

Stage 1:Apply Power to +ve & -ve

Stage 2: Apply Power to +ve & -ve, Connect Stage 2 to +ve

Stage 3: Apply Power to +ve & -ve, Connect Stage 3 to +ve

Stop: Apply Power to +ve & -ve, Connect Stop to +ve

24/03/2022

24/03/2022

24/03/2022

BExH120D DC SOUNDER WIRING DIAGRAMS

INTRODUCTION

INTRODUCTION

1

RSR - 05/09/2022

 -ve

+ve

Stage 2

-ve

Stage 3

R1

SWITCHES FOR STAGE OPERATION

CUSTOMER SUPPLIED

+ve

Stop

Stage 2

-ve

Stage 3

+ve

Stop

+ve

-ve

+ve

-ve

Stop

S3

S2

Stop

S3

S2

(Set Header pins to +ve switching)

+

C/-

2

3

Stop

R1

+

C/-

2

3

Stop

R1

+

C/-

2

3

Stop

Summary of Contents for 1-22-070

Page 1: ...e current levels shown above are for the 440Hz Continuous tone nominal input voltage Nominal current at nominal voltage Table 1 Electrical Ratings It is important that a suitable power supply is used...

Page 2: ...f it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Group IIC Hydrogen and Acetylene up to 55 C ambient Temperature Classification for Gas Applications T1...

Page 3: ...tightened to ensure that the unit cannot move in service Fig 1a Fixing Location for Sounder Flare Fig 1b Fixing Location for Sounder Radial 7 Access to the Flameproof Enclosure To access the Ex d cha...

Page 4: ...both located on the terminal chamber section of the unit Fig 3 Internal View of Cover When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the incoming ear...

Page 5: ...he left hand marked ve and centre pins For ve switching connect the headers to the right hand marked ve and the centre pins Refer to Fig 7 2 3 S top 1 2 3 S2 S3 Stop ve ve Stage Headers Set for ve Swi...

Page 6: ...lectro Mechanical Buzzer Sound 2 Sound 5 Sound 5 Mechanical Bell Sound 1 Sound 2 13 1 Volume Control The output level of the BEx sounder can be set by adjusting the volume control potentiometer see Fi...

Page 7: ...LINE MONITORING RESISTOR CUSTOMER SUPPLIED 500 MIN 2W MIN OR 3K3 MIN 0 5W MIN MINIMUM VALUES R1 Single Stage Configuration Config 1a Line Monitoring Header pins set to negative switching default Stage...

Page 8: ...HT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D210 06 035 R...

Page 9: ...nds B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIB or IIC T4 Gb II 2G Ex db eb IIB or I...

Page 10: ...are in accordance with the restriction of the use of hazardous substances in electrical and electronic equipment including amendment by Directive 2015 863 EU Regulation EC 1907 2006 Registration Evalu...

Page 11: ...duction process Module D Sira Certification Service Notified Body No 0518 Rake Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the eq...

Page 12: ...and Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the...

Reviews: