11.  AC Wiring 

 

N  L

-   2

   3  S

to

p

1
23

 

 

Fig. 4 AC Terminals 

 

12.  DC Wiring 

+  -
   

  3

  S

to

p

1
23

S2

S3

Stop +ve

-v

e

 

Fig. 6 DC Terminals 

 

12.1 Stop Terminal 

 

 

The user can remotely activate and deactivate the BExH120D 
Hootronic  DC  sounder  by  switching  a  connection  from  the 
“Stop” terminal to the –ve or +ve supply lines, depending on 
which switching mode is being used +ve or –ve (see above) 
whilst  the  unit  is  powered.  To  achieve  the  “tail  off”  sound  at 
switch off the unit must remain powered. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

12.2 Stage Switching Polarity (DC Units Only)

 

 

The BExH120D DC sounders have the facility to use ve 
or –ve switching to change the tone to the second and third 
stages.  Negative  switching  is  the  default  setting.  For  –ve 
switching connect the two headers on the pcb to the left-hand 
(marked –ve) and centre pins. For +ve switching connect the 
headers to the right hand (ve) and the centre pins. 
(Refer to Fig. 7) 

+

  -   2

   3 
 S

to

p

1
23

S2

S3

Stop +v

e

-ve

 

 

Stage Headers Set for –ve Switching 

 

 

 

Stage Headers Set for +ve Switching 

 

Fig. 7 Stage Switching Polarity 

 

12.3 Line Monitoring

 

 

On  BExH120D  DC  units,  dc  reverse  line  monitoring  can  be 
used if required. All DC sounders have a blocking diode fitted 
in their supply input lines. An end of line monitoring diode or 
an end of line monitoring resistor can be connected across the 
+ve and –ve terminals. If an end of line resistor is used it must 
have  a  minimum  resistance  value  of  3k3Ω  and  a  minimum 
power  rating  of  0.5  watts  or  a  minimum  resistance  value  of 
500Ω and a minimum power rating of 2 watts. 
 
The resistor must be connected directly across the +ve and -
ve terminals as shown in the following drawing. The resistor 
leads should be kept as short as possible.  

+  -  

 2   3

  S

top

1
23

S2

S3

Stop +v

e

-v

e

 

Fig. 8 End of Line Resistor Placement

 

 

End of Line Resistor

Stage Headers 

AC 

Terminals 

N  

 

 

C/- 

 

S2 

 

S3 

 

Stop 

C/- 

Sound Headers 

 

C/- 

 

S2 

 

S3 

 

Stop 

C/- 

Stage 
Headers 

C/- 

Summary of Contents for 1-22-070

Page 1: ...e current levels shown above are for the 440Hz Continuous tone nominal input voltage Nominal current at nominal voltage Table 1 Electrical Ratings It is important that a suitable power supply is used...

Page 2: ...f it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Group IIC Hydrogen and Acetylene up to 55 C ambient Temperature Classification for Gas Applications T1...

Page 3: ...tightened to ensure that the unit cannot move in service Fig 1a Fixing Location for Sounder Flare Fig 1b Fixing Location for Sounder Radial 7 Access to the Flameproof Enclosure To access the Ex d cha...

Page 4: ...both located on the terminal chamber section of the unit Fig 3 Internal View of Cover When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the incoming ear...

Page 5: ...he left hand marked ve and centre pins For ve switching connect the headers to the right hand marked ve and the centre pins Refer to Fig 7 2 3 S top 1 2 3 S2 S3 Stop ve ve Stage Headers Set for ve Swi...

Page 6: ...lectro Mechanical Buzzer Sound 2 Sound 5 Sound 5 Mechanical Bell Sound 1 Sound 2 13 1 Volume Control The output level of the BEx sounder can be set by adjusting the volume control potentiometer see Fi...

Page 7: ...LINE MONITORING RESISTOR CUSTOMER SUPPLIED 500 MIN 2W MIN OR 3K3 MIN 0 5W MIN MINIMUM VALUES R1 Single Stage Configuration Config 1a Line Monitoring Header pins set to negative switching default Stage...

Page 8: ...HT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D210 06 035 R...

Page 9: ...nds B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIB or IIC T4 Gb II 2G Ex db eb IIB or I...

Page 10: ...are in accordance with the restriction of the use of hazardous substances in electrical and electronic equipment including amendment by Directive 2015 863 EU Regulation EC 1907 2006 Registration Evalu...

Page 11: ...duction process Module D Sira Certification Service Notified Body No 0518 Rake Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the eq...

Page 12: ...and Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the...

Reviews: