EN • 8
ENGLISH
FRANCAIS
NEDERLANDS
ESP
AÑOL
IT
ALIANO
DEUTSCH
664Y3400
TECHNICAL CHARACTERISTICS
Electrical data of model 09
STAGE
1
STAGE
2
TOTAL
POWER
TERMINALS
Tri phase 8.4 kW
(*)
Terminals 1 and 2 shunted
Terminal 3 L1 (
A
) 6
6
12
Terminals 5 and 6 shunted
Terminal 4 L2 (
A
)
12 0 12
Relay K4 activated
Terminal 5 L3 (
A
) 6
6
12
Terminal 1
N (
A
)
6 6 0
Power
(
kW
)
5.6 2.8 8.4
1
N
2
3
L1
4
L2
5
L3
6
Tri phase 7 kW
(***)
Terminals 1 and 2 shunted
Terminal 3 L1 (
A
) 6
6
12
Relay K4 activated
Terminal 4 L2 (
A
)
12 0 12
Terminal 5 L3 (
A
)
6 0 6
Terminal 1
N (
A
)
6 6 6
Power
(
kW
) 5.6
1.4
7
1
N
2
3
L1
4
L2
5
L3
6
Tri phase 5.6 kW
(***)
Terminals 1 and 2 shunted
Terminal 3 L1 (
A
)
0 6 6
Terminals 5 and 6 shunted
Terminal 4 L2 (
A
)
6 0 6
Relay K4 disactivated (**)
Terminal 5 L3 (
A
) 6
6
12
Terminal 1
N (
A
)
6 6 6
Power
(
kW
)
2.8 2.8 5.6
1
N
2
3
L1
4
L2
5
L3
6
Tri phase 4.2 kW
Terminals 1 and 2 shunted
Terminal 3 L1 (
A
)
0 6 6
Relay K4 disactivated (**)
Terminal 4 L2 (
A
)
6 0 6
Terminal 5 L3 (
A
)
6 0 6
Terminal 1
N (
A
)
6 6 0
Power
(
kW
)
2.8 1.4 4.2
1
N
2
3
L1
4
L2
5
L3
6
Single phase 8.4 kW
Terminals 1 and 2 shunted
Terminal 3 L1 (
A
)
24 12 36
Terminals 3, 4, 5 and 6 shunted
Terminal 1
N (
A
)
24 12 36
Relay K4 activated
Power
(
kW
)
5.6 2.8 8.4
1
N
2
3
L
4
5
6
Single phase 7 kW
Terminals 1 and 2 shunted
Terminal 3 L1 (
A
)
24 6 30
Terminals 3, 4 and 5 shunted
Terminal 1
N (
A
)
24 6 30
Relay K4 activated
Power
(
kW
) 5.6
1.4
7
1
N
2
3
L
4
5
6
Single phase 5.6 kW
Terminals 1 and 2 shunted
Terminal 3 L1 (
A
)
12 12 24
Terminals 3, 4 and 5 shunted
Terminal 1
N (
A
)
12 12 24
Relay K4 disactivated (**)
Power
(
kW
)
2.8 2.8 5.6
1
N
2
3
L
4
5
6
Single phase 4.2 kW
Terminals 1 and 2 shunted
Terminal 3 L1 (
A
) 12
6
31.2
Terminals 3, 4 and 5 shunted
Terminal 1
N (
A
) 12
6
31.2
Relay K4 disactivated (**)
Power
(
kW
)
2.8 1.4 4.2
1
N
2
3
L
4
5
6
This values are based on standard supply voltage in Europe, that is 1 x 230V for single phase and 3 x 400V + N for tri phase.
(*) Factory configuration / (**) Remove the shunt 21 and 22 in order to deactivate the relay / (***) Current not balanced.