TECHNICAL CHARACTERISTICS
Electrical data of model 28
STAGE
1
STAGE
2
TOTAL
POWER
TERMINALS
Tri phase 28.8 kW
(*)
Terminals 3 and 4 shunted
Terminal 2 L1 (
A
)
20.8 20.8 41.6
Terminals 5 and 6 shunted
Terminal 3 L2 (
A
)
20.8 20.8 41.6
Relay K5 activated
Terminal 5 L3 (
A
)
20.8 20.8 41.6
Terminal 1
N (
A
)
0 0 0
Power
(
kW
)
14.4 14.4 28.8
1
N
2
L1
3
L2
4
5
L3
6
Tri phase 26.4 kW
(***)
Terminals 3 and 4 shunted
Terminal 2 L1 (
A
)
20.8 20.8 41.6
Relay K5 activated
Terminal 3 L2 (
A
)
20.8 20.8 41.6
Terminal 5 L3 (
A
)
20.8 10.4 31.2
Terminal 1
N (
A
) 0
10.4 10.4
Power
(
kW
)
14.4 12 26.4
1
N
2
L1
3
L2
4
5
L3
6
Tri phase 24 kW
(***)
Relay K5 activated
Terminal 2 L1 (
A
)
20.8 20.8 41.6
Terminal 3 L2 (
A
)
20.8 10.4 31.2
Terminal 5 L3 (
A
)
20.8 10.4 31.2
Terminal 1
N (
A
) 0
10.4 10.4
Power
(
kW
) 14.4
9.6
24
1
N
2
L1
3
L2
4
5
L3
6
Tri phase 21.6 kW
Terminals 3 and 4 shunted
Terminal 2 L1 (
A
)
20.8 10.4 31.2
Terminals 5 and 6 shunted
Terminal 3 L2 (
A
)
20.8 10.4 31.2
Relay K5 disactivated (**)
Terminal 5 L3 (
A
)
20.8 10.4 31.2
Terminal 1
N (
A
)
0 0 0
Power
(
kW
)
14.4 7.2 21.6
1
N
2
L1
3
L2
4
5
L3
6
This values are based on standard supply voltage in Europe, that is 1 x 230V for single phase and 3 x 400V + N for tri phase.
(*) Factory configuration / (**) Remove the shunt 23 and 24 in order to deactivate the relay / (***) Current not balanced.