19
5.4. Required installation dimensions - mounting cut-out
The
PowerPlex
®
Mini Module are meant for front panel mounting. The modules are screwed onto the mounting
plate from the front, e.g. in the side trim panel. The required dimensions are shown in Fig. 8.
Fig. 8: Dimensions of the PowerPlex® Mini Module
All cables are connected to the module from below. This has to be considered in the planning stage and ensures
ease of mounting, preventing a possible kinking of the cables.
5.5. Dimensions and space requirements
According to EMC conditions there must always be sufficient space between the different electrical devices. Space
requirement of a device depends on its dimensions shown in Fig. 9.
Delivery of a standard
PowerPlex
®
Mini Module does not include any mating plugs. They can be ordered
separately as accessories XPP-CP-130:
Information
The protection degree IP22 is achieved when the
PowerPlex
®
Mini Module is installed vertically with
the terminals pointing downwards.