background image

39

38

39

CHANGING 

    

optic 

CARTRIDGE

38

CHANGING THE 

 OPTIC CARTRIDGE OUTSIDE NORMAL PROCEDURE

You may need to have to change the cartridge before the expiration of the number of 

flashes initially planned, when, for example, a tube has been broken, or is not working 

anymore. For any change of optical cartridge outside the normal procedure, please 

strictly refer to the instructions given by our technical department.

RENTAL MODE

• Plug in and turn on your device 

10

• Once the home screen is displayed, go to the “Consumables” menu.
• Select icon 

17

, which corresponds to the addition of flashes (screen 

W

).

• With the help of the digital keyboard (screen 

X

):

-  Enter the first cartridge code, and validate with the “V” button.

-  Enter the second cartridge code, and validate with the “V” button.

•  A message specifying that the codes are valid will then be displayed. You must click OK.
•  The "Consumables" menu appears (screen 

W

); the modification of the days’ credit 

meter means that they have been increased accordingly.

•  Using the go back icon 

8          

, it is possible to go back to the home screen.

The “C” button enables you to correct the digits in each box.

If you have entered a wrong code, after validation, an error message will be displayed: 

the “Consumables” menu appears again (screen 

W

).

If the days’ code entered is correct, the message "Valid codes" will be displayed on the 

screen. Adding days’ credit only concerns the 

 in rental mode. This section does 

not concern the sale mode.

If you have a 

 which requires an activation code for your cartridge, then you can access this from your personal client space.  

Please go to 

https://prostore.esw-beauty.com

 and enter your email address and password. You can then access your personal 

space, by clicking on your name on the top right of the page and clicking on ‘Your account’. Click on Training questions and Activation 

codes.  You will then see your E-Swin products. Click on the blue box – Activation codes. Under the tab ‘Available optical cartridges’ 

you will be able to see your cartridges and activate using the corresponding serial number which is written on your cartridge. You 

will receive two 5-digit codes to enter into your 

. You can also refer to this page to see all historical information referring 

to activation codes.

IMPORTANT: 

Only our technical department is authorised to ask you to 

change the optic cartridge outside the normal procedure. Any change of 

 

optic

 cartridge and/or inserting new cartridge codes without being 

instructed by our technical team, will result in the irreversible loss of the 

remaining number of flashes on your 

 

optic

 cartridge; you will then 

need to buy a new 

 

optic

 cartridge

.

X

885

Numeric keypad

V

885

885

Consumables

W

885

885

Consumables

IMPORTANT: 

Unlike cartridge change, you're not required to wait until the 

days’ credits have run out to add more days. The additional days will be 

added to the residual number of days.

Please go to 

https://prostore.esw-beauty.com

 and enter your email address and 

password.  From there, click on the products tab and then Monthly Rental which 

is situated underneath. 
You can then purchase your rental days. To activate these rental days, you must 

access your personal space by clicking on your name on the top right of the page 

and clicking on ‘Your account’. Click on Training questions and Activation codes.  

You will then see your E-Swin products. Click on the blue box – Activation codes.  

Under the tab ‘Your rental credit’ you can activate your day codes.  These will be 

two 5-digit codes. You can also refer to this page to see all historical information 

referring to activation codes.

17

8

10

4

Summary of Contents for E-O75

Page 1: ...User Manual...

Page 2: ...ll see is an exceptional product I hope that you will be completely satisfied with your device and that you will share your experience on our company s official website prostore esw beauty com Yours S...

Page 3: ...V delivered in its own plastic case REMINDER Only E Swin is entitled to market and its accessories optic stop clean patches pen gel mask fun etc on the shop prostore esw beauty com PACKAGE CONTENTS W...

Page 4: ...manufacturer When using the device make sure to place it on a flat surface in a place where all risk of falls will be avoided E Swin SAS disclaims any responsibility for any damage resulting from imp...

Page 5: ...ore starting a session the patient must not apply any cosmetic treatments which are aggressive to the skin In the case of non aggressive cosmetic treatments however a time interval of 24 hours should...

Page 6: ...system is used y METHODE OF TREATMENT BEFORE THE SESSION Explain the technology and the principle of depilation to the patient Identify any contra indication for the use of pulsed light Specify the co...

Page 7: ...y for devices Applicator holding area Vizor to protect touchscreen Mobile head Release clips for the mobile head Mobile head Applicator zone Applicator zone Air vents Trigger button Flash ready indica...

Page 8: ...ght energy desired 17 Set of all precautions to observe imperatively before each use 18 Pause icon to pause the flashing session Pressing this icon puts in pause mode This mode prohibits the applicato...

Page 9: ......

Page 10: ...ustbeflatandregular It must be clean and dust free For better efficiency of it is recommended to clean the filter before every use with the spray clean that is provided when you purchase Any damaged f...

Page 11: ...hese codes will no longer be requested 2 CARTRIDGE CODES You own a Cartridge codes 5 characters followed by another set of 5 characters must be entered each time you renew the optic cartridge These co...

Page 12: ...can treat your patient with Depilatory cream You can only treat your patient with 1 week after their last depilatory cream treatment Waxing electric epilator tweezers You can only treat your patient w...

Page 13: ...skin when the flash is delivered Increased potential rashes or burns on highly pigmented skins olive after a session IMPORTANT Thedarkertheskiniswhetherbynatureorafteratan themoreyouhavetobecareful ab...

Page 14: ...use stop to cover a rather large area that must be flashed tattoos REMINDER Make sure that you are applying a thick layer of gel The gel must never overflowinsidethemobileheadofthedevice When selectin...

Page 15: ...tor optical guide must be applied on the skin Then press in order to clip the head of the applicator Take care of stretching the skin where it is the thinnest so that the glass tip optical guide of th...

Page 16: ......

Page 17: ...ut the cartridge delicately and remove it completely image G A 0 6 Consumables Configuration NOTE Unlike the fans located inside the applicator that stop running after a certain period fans located in...

Page 18: ...as it may create serious damage to your device You must return the damaged cartridge to us and order another one Check the cartridge has been well engaged y STEP 6 CLEANING EXTERNAL AND INTERNAL OPTI...

Page 19: ...rocedure please refer strictly to the instructions given by our technical department y STEP 9 ONLY FOR IN THIS CASE IT IS COMPULSORY TO ENTER ACTIVATION CODES FOR THE OPTIC CARTRIDGE Plug in and turn...

Page 20: ...ss your personal space byclickingonyournameonthetoprightofthepageandclickingon Youraccount ClickonTrainingquestionsandActivation codes You will then see your E Swin products Click on the blue box Acti...

Page 21: ...ANGUAGE SELECTION screen D Press on the flag corresponding to the requested language The message Language has been switched is displayed you must then press OK for the change to become effective The L...

Page 22: ...ptic car tridge is dismounted only touch the plastic parts and definitely not the electrodes the tube or the reflector Never try touching the contact elements Never attempt to dismount the applicator...

Page 23: ...is then possible to apply flash treatment to the entire area without worrying about beauty spots The patches are removed at the end of the session The fun stencils are used to mark out zones which are...

Page 24: ...tor BODY OF THE APPLICATOR Clean all of the plastic parts of the applicator with a clean cloth which has been dampened with water without any additives y BASE CABLE TO APPLICATOR Thiscablemustalwaysst...

Page 25: ...SECU02 No cartridge detected The device doesn t work Insert the optic cartridge by carefully following the handling instructions SECU06 Temporary blocking Wait for the procedure that cools down the op...

Page 26: ...oduct after the deadline specified beside this logo gel The batch number of the product is indicated beside this logo gel y RECYCLING AND TREATMENT Instructions for treatment of used products the WEEE...

Page 27: ...network Surge IEC 61000 4 5 1 kV differential mode 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical public low voltage power supply network Vol...

Page 28: ...ment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which is used exceed the applicable RF compliance level above sh...

Page 29: ...l void the warranty E SWIN SAS will not be held responsible for any accident that may occur due to improper use or non compliance with the prescriptions of the present manual or the various informatio...

Page 30: ...www e swin com 0197 ZA de la Pr v t Rue des C tes d Orval 78550 Houdan FRANCE 01 30 46 37 61 Ref M015GB000C12A rev C 2021 09 21 Copyright by E SWIN All rights reserved...

Reviews: