![e-survey E3L User Manual Download Page 73](http://html1.mh-extra.com/html/e-survey/e3l/e3l_user-manual_3147136073.webp)
SHANGHAI ESURVEY GNSS CO., LTD.
63
Note:
The horizontal angle defaults to tolerance of engineering first-order
traverse, and vertical angle defaults to tolerance of the fifth class triangular
elevation.
5. Press
F4 SET
for confirmation.
5.2.10.2.2 Set the Station
To set the station, do the following:
1. In
LEAD MEASURE
display, press
F2
/
2
. The following display shows:
2. Set the following:
o
New Stn
: a new survey station.
o
Hi
: the height of the instrument.
Note:
This value is defaulted to
0
. Please input an accurate value
before next step. Otherwise, the buzzer sounds and the proceeding
operation is impossible.
o
BsPt
: the backsight point.
o
Point
: the foresight point.
3. Press
F4 SET
for confirmation.
If a mistake is found after station setting succeeds, press
ESC
to quit the entire program
and reenter.
5.2.10.2.3 Measure the Point
To measure the point, do the following:
1. In
LEAD MEASURE
display, press
F3
/
3
. The following display shows:
2. Set the following:
o
Rht
: the height of the prism.
o
Meas Num
: the number of observation sets.
3. Press
F1 ALL
to trigger measurement.
Summary of Contents for E3L
Page 1: ...Shanghai eSurvey GNSS Co Ltd 1st Edition V1 1 E3L USER GUIDE TOTAL STATION...
Page 2: ......
Page 4: ...SHANGHAI ESURVEY GNSS CO LTD...
Page 10: ...SHANGHAI ESURVEY GNSS CO LTD VI...
Page 40: ...SHANGHAI ESURVEY GNSS CO LTD 30 Orthogonal Stake out The principle is as follows...