- 9 -
Prefix / Suffix Setup
Description:
To setup prefix and suffix parameters, changes will be effective after
scanner ACK response.
Host Requirement:
To setup prefix and suffix with a control characters use the following
table:
[NUL] [SOH] [STX] [ETX] [EOT]
[ENQ] [ACK] [BEL] [BS] [HT]
[LF] [VT] [FF] [CR] [SO]
[SI] [DLE] [DC1] [DC2] [DC3]
[DC4] [NAK] [SYN] [ETB] [CAN]
[EM] [SUB] [ESC] [FS] [GS]
[RS] [US] [DEL]
Example:
setting suffix with AbC, Carriage Return and Line Feed is
“SOH”<SUFFIX=AbC[CR][LF]>” EOT”
Then, the suffix value is added to the end of every good read, the control characters are
sent in ASCII characters.
Code Identifier:
If the code identifier is enabled, then the standard AIM ID is added to
the prefix. The AIM ID values are the following:
Code39
]A
Code128
]C
PDF417
]L
Magnetic
]M
The Code identifier is added to the end of the prefix value.
Scanner Response:
ACK / NAK
Description
Field
Values allowed
Prefix
Set
PREFIX=
Add Code Identifier
Enable
PRECID=1
Disable *
PRECID=0
Suffix
Set
SUFFIX=
Add CR to Suffix
Enable
SUFFCR=1
Disable *
SUFFCR=0
Table 2.4
Summary of Contents for 200