- 8 -
Registration Key Read & Write
Description:
To setup Registration Key, changes will be effective after scanner ACK
response. Control characters are not permitted. The maximum length is 30 characters*.
When the REGIEN option is enabled, the data will be added between serial number and
decoded data.
Example:
„SOH‟<REGKEY:>„EOT‟
Scanner Response:
ACK “XXXXXXXXXX…\r\n” / NAK
X is a printable ASCII, with variable length
Scanner Response:
ACK / NAK
Description
Field
Values allowed
Reg. Key Read
REGKEY:
Add to stream
Enable
REGIEN=1
Disable *
REGIEN=0
Reg. Key Write
REGKEY=
Table 2.2
* Do not use write function on every scanner reads, the maximum write is 10,000 times.
Speaker Setup
Description:
To setup speaker volume, power-up beeps and parameter beeps (beeps
after changing the scanner setup via serial port). Changes will be effective after scanner
ACK response.
Scanner Response:
ACK / NAK
Description
Field
Values allowed
Speaker Volume
Off
SPVOLU=OFF
Low
SPVOLU=LOW
Medium *
SPVOLU=MEDIUM
High
SPVOLU=HIGH
Power-Up Beeps
Enable *
SPPOWB=1
Disable
SPPOWB=0
Parameter Beeps
Enable *
SPPARA=1
Disable
SPPARA=0
Table 2.3