Sliding the switch to OFF position will turn off the light 
fixture permanently. The detection function will also be 
turned off.    The unit will enter sleep mode to conserve 
battery power. 
 

Upon first connecting to AC mains supply, the unit will 
start  working  according  to  one  of  the  following 
scenarios: 
 
Scenario  A:  if  and  when  the  battery  level  is  higher  or 
equal  to  half-full  voltage,  the  unit  won’t  charge  its 
battery.   
 
Scenario B: if and when the battery level is lower than 
half-full  voltage,  the  unit  will  charge  its  battery  to  full 
voltage. 
 
The following scenario will be applicable, subject to AC 
mains  supply  being  connected  (not  the  first  time 
connection): 
 
Scenario  C:  if  and  when  the  battery  level    is  lower 
than half-full voltage, the unit will charge its battery to 
full voltage. 

 

TROUBLESHOOTING

TROUBLESHOOTING

TROUBLESHOOTING

TROUBLESHOOTING

 

Battery cannot be charged 

 

Replace a new lithium battery. 

Red LED keep flashing three times every 30 
seconds more than 2 days 

 

Replace a new lithium battery. 

 

Replace a new light fixture which meets product 
specifications. 

Unit cannot control connected light fixture 

 

Setting the unit again according to the manual as 
instructed. 

 

Fit the lithium battery as supplied. 

 

Replace a new lithium battery. 

 

Send the unit for repair; do not try to take apart 
the unit. 

 

Capacitor 

For  loads  Below  40  Watt  incandescent  please  fit  the 
supplied  capacitor  across  live  and  neutral  in  the  light 
fitting.     
If above 40w the capacitor is not required to be fitted. 

 
 
 
 
 
 
 

SPECIFICATIONS

SPECIFICATIONS

SPECIFICATIONS

SPECIFICATIONS

 

Power Requirement  AC 220 ~ 240V / 50Hz 

Lighting Load 

Max. Incandescent: 2000W 
Min. Incandescent : 40W 
Max. Halogen: 1000W 
Max. Fluorescent / Cos 

Ө

 

=0.5: 1000W 
Max CFL/ PL/ LED : 

10 

pieces for low power lamps; the 
fitting quantity may reduce for 
high power lamps. 

Battery Type 

Lithium 3.7V 

Detection Angle 

Up to 110

°

  at 25

°

C at 1.7m 

Height 

Detection Distance 

Up to 10m at 25

°

C at 1.7m 

Height 

Mounting Height 

Recommended at least 1.7m 
(5.57 Ft) Wall Mount   

Slide Switch Control  Auto/Off   

Time Adjustment 

10 settings – 5, 10, 20, 40, 
80, 160 seconds and 5, 10, 20, 
40 minutes 

Lux Adjustment 

Approx. 30 ~ 200 Lux 

Warm Up Time 

About 1 min 

Protection Class 

Class II 

Protection Degree 

IP20 

Safety 

CE 

*Specifications are subject to change without notice. 

 

   

 

             

Warning: 

Do  not  dispose  of  electrical  appliances  as  unsorted 
municipal waste, use separate collection facilities.   
 
Contact  your  local  government  for  information 
regarding the collection systems available. 
 
If  electrical  appliances  are  disposed  of  in  landfills  or 
dumps,  hazardous  substances  can  leak  into  the 
groundwater  and  get  into  the  food  chain,  damaging 
your health and well-being. 
 
When  replacing  old  appliances  with  new  once,  the 
retailer  is  legally  obligated  to  take  back  your  old 
appliance for disposal at least for free of charge. 
 
 
E-Matic Energy Management Solutions, 
10 Sandersons Way, Marton,   
Blackpool, Lancashire, FY4 4NB

.

 

Tel: 01253 791888, Fax: 01253 791887,                                         
Web site: www.e-matic.co.uk 
Email: 

[email protected]

 

 

A501111682R02 

Rev04 

Reviews: