5
Manual Off
Sliding the switch to OFF position will turn off the light
fixture permanently. The detection function will also be
turned off. The unit will enter sleep mode to conserve
battery power.
Upon first connecting to AC mains supply, the unit will
start working according to one of the following
scenarios:
Scenario A: if and when the battery level is higher or
equal to half-full voltage, the unit won’t charge its
battery.
Scenario B: if and when the battery level is lower than
half-full voltage, the unit will charge its battery to full
voltage.
The following scenario will be applicable, subject to AC
mains supply being connected (not the first time
connection):
Scenario C: if and when the battery level is lower
than half-full voltage, the unit will charge its battery to
full voltage.
TROUBLESHOOTING
TROUBLESHOOTING
TROUBLESHOOTING
TROUBLESHOOTING
Battery cannot be charged
Replace a new lithium battery.
Red LED keep flashing three times every 30
seconds more than 2 days
Replace a new lithium battery.
Replace a new light fixture which meets product
specifications.
Unit cannot control connected light fixture
Setting the unit again according to the manual as
instructed.
Fit the lithium battery as supplied.
Replace a new lithium battery.
Send the unit for repair; do not try to take apart
the unit.
Capacitor
For loads Below 40 Watt incandescent please fit the
supplied capacitor across live and neutral in the light
fitting.
If above 40w the capacitor is not required to be fitted.
SPECIFICATIONS
SPECIFICATIONS
SPECIFICATIONS
SPECIFICATIONS
Power Requirement AC 220 ~ 240V / 50Hz
Lighting Load
Max. Incandescent: 2000W
Min. Incandescent : 40W
Max. Halogen: 1000W
Max. Fluorescent / Cos
Ө
=0.5: 1000W
Max CFL/ PL/ LED :
10
pieces for low power lamps; the
fitting quantity may reduce for
high power lamps.
Battery Type
Lithium 3.7V
Detection Angle
Up to 110
°
at 25
°
C at 1.7m
Height
Detection Distance
Up to 10m at 25
°
C at 1.7m
Height
Mounting Height
Recommended at least 1.7m
(5.57 Ft) Wall Mount
Slide Switch Control Auto/Off
Time Adjustment
10 settings – 5, 10, 20, 40,
80, 160 seconds and 5, 10, 20,
40 minutes
Lux Adjustment
Approx. 30 ~ 200 Lux
Warm Up Time
About 1 min
Protection Class
Class II
Protection Degree
IP20
Safety
CE
*Specifications are subject to change without notice.
Warning:
Do not dispose of electrical appliances as unsorted
municipal waste, use separate collection facilities.
Contact your local government for information
regarding the collection systems available.
If electrical appliances are disposed of in landfills or
dumps, hazardous substances can leak into the
groundwater and get into the food chain, damaging
your health and well-being.
When replacing old appliances with new once, the
retailer is legally obligated to take back your old
appliance for disposal at least for free of charge.
E-Matic Energy Management Solutions,
10 Sandersons Way, Marton,
Blackpool, Lancashire, FY4 4NB
.
Tel: 01253 791888, Fax: 01253 791887,
Web site: www.e-matic.co.uk
Email:
A501111682R02