3
Note:
Ensure it is connected to AC mains supply and
the battery is connected for a minimum of 4
hours to ensure the battery has adequate
charge for testing. To Fully charge can take up
to 10 hours.
Turn the Lux control and the Time control
counter-clockwise to the edge- the TEST position.
(FIGURE 8)
FIGURE 8
Turn the slide switch to AUTO position, the unit
starts checking the AC mains supply for about 2
minutes as maximum. After completion of AC
mains supply check-up, it will start warming up for
about 1 minute, during which red LED will stay on.
Walk through the coverage area. The
connected light fixture will turn on for about 5
seconds when motion is detected and turn off
shortly after motion stops. Wait for the light to
turn off before
moving again to test the sensor.
(2) SETTINGS
TIME ADJUSTMENT
The TIME adjustment controls how long the light will
stay on after motion has been detected.
Adjust the TIME control knob clockwise to increase the
turn-off
time
(40
minutes
maximum)
or
counter-clockwise to decrease the turn-off time (5
seconds minimum). The time adjustment knob has
10 settings, including 5, 10, 20, 40, 80, 160 seconds
and 5, 10, 20, 40 minutes. (FIGURE 9)
FIGURE 9
When setting the TIME adjustment to 1 minute, once
motion has been detected, the connected light fixture
will stay on for 1 minute. However, if continuous
movement has been detected within 1 minute, the
sensor will restart the time interval thus prolonging the
illumination period.
LUX ADJUSTMENT
The LUX adjustment determines at what light level the
light will start operating when you set the sensor to the
AUTO mode.
FIGURE 10a FIGURE 10b
Note:
“T” means that the light will always switch on
regardless of light levels in the area. (FIGURE 10a)
Provisionally turn the LUX control knob to the edge
clockwise at the “moon” (dusk) position. (FIGURE 10b)
Wait until the ambient light level reaches the level of
darkness at which you wish to turn the lights on.
Slowly rotate the knob anti-clockwise until the light
turns on.
At this position the unit should become operative at
approximately the same level of darkness each
evening. Observe the operation.
If the unit starts to operate too early, adjust the knob
slightly clockwise. If the unit operates too late (i.e.
dusk), adjust the knob slightly anti-clockwise.
OPERATION
Automatic Operation
There is a slide switch located on brim of the cabinet.
Slide the switch to AUTO position. (FIGURE 11) When
the sensor detects motion, the light automatically turns
on for the preset length of time. After the elapse of
each detection, the sensor will not react to any
movement for 3 seconds. The built-in photocell turns
the sensor off and on according to the light level
selected by the LUX adjustment. When no movement
has been detected, the sensor will consume less
power thus saving battery power.
about 3sec
about 40min
About 5 sec.
About 40 min.
T
moon