background image

basic

setup

output ec

ho loss

• alar

m

• hold

• r

amp%/min

*

medium pr

oper

ty

• unkno

wn

• < 1.9

• 1.9 ...

4

• 4 ...

10

• > 10

pr

ocess condition

• standard

• calm surf

ace

• turb

ulent surf

ace

• additional agitator

• f

ast change

• test:

no filter

dela

y time

0

in case of

echo loss

max.

4000 [s]

(s

)

*

empty calibration

[ m / f

eet]

distance flange to

min.

le

v

e

l

full calibration

[ m / f

eet ]

span

pipe

diameter

inside diameter

b

y

pass/stilling w

ell

distance /

measured v

alue

distance       m/ft

• meas

.

v

alue m/ft

selection

(not f

o

r

T

oFT

o

ol/

and Comm

uwin II)

saf

ety

settings

mounting

calibration

lineari-

sation

linearisation

• linear [%]

le

vel / ulla

ge

• le

v

el CU

• ullage CU

Ramp

% span / min

saf

ety distance

from tip of antenna

or lo

w

er edge of

hor

n

in saf

ety distance

alar

m

• w

a

rning

• self holding

*

o

ver

spill

pr

otection

standard

•W

H

G

reset

self holding

• no

• y

e

s

e

xtended

calibration

max.

scale

[%]

Histor

y reset

linearisation

tab

le No

.

linearisation

le

v

el [m]

dip tab

le

linearisation

v

olume [%]

ne

xt point:

• y

e

s

•n

o

customet unit

see tab

le

actual

mapping distance

mapping

• inactiv

e

• activ

e

• delete

star

t mapping

off on

ec

ho quality

[dB]

output damping

[s]

offset

[m]

will be added to the

measured le

ve

l

b

loc

k.

distance

[m]

c

hec

k distance

• d

istance =  ok

• too small •

man

ual

mapping rang

e

input of mapping range

00

01

03

04

05

0               1                2               3               4               5               6              7              

 8                9

gr

oup

selection

selection of customer units

0:

%

1:

liter

2:

hl

3:

m3

4:

dm3

5:

cm3

Micr

opilot S,

FMR 53x men

u structure HAR

T  (displa

y module)

• clear tab

le

output on alarm

xx.xx mA

auto correction

• on

• off

correction

pipe diameter

• on

• off

output on alarm

• MIN  (3.6 mA)

• MAX (22 mA)

• hold

*

tank gauging

• dip tab

le

• auto correction

max.

scale

[%]

diameter vessel

[m]

jump to

matr

ix field 51

tank shape

• dome ceiling

hor

iz

ontal cyl.

• v

e

rtical cylinder

• sphere

• b

ypass

• stilling w

ell

dip tab

le

• vie

w

man

ual

• semi-automatic

• tab

le on

• tab

le off

• clear tab

le

dip tab

le handl.

• ne

xt point

p

re

vious point

• store point • delete point • ne

w point

• edit point

measured v

alue

00.000

12:

ton

13:

m

14:

ft

15:

mm

16:

inch

17:

none

comm

unication

ad

dress

[0...15]

(if > 0 then m

ultidrop

function, current

output fix

ed at 4 mA!)

present err

or

pre

vious err

or

c

lear last err

or

• k

eep

• er

ase

reset

x

for reset code see man

ual

output

displa

y

dia

gnostics

06

09

0A

No.

of preamb

les

for HAR

T [4...20]

langua

g

e

bac

k to home

3...9999 seconds

application para-

meter

(V0H2-3-4)

not changed

• changed

custod

y mode

• inactiv

e

• activ

e positiv

e

• activ

e negativ

e

displa

y f

ormat

• decimal

• 1/16" (inch)

displa

y test

(not f

o

r

T

oFT

ool

and Comm

uwin II)

• off

• on [1s]

sep.

c

haracter

.

(per

iod)

• , (comma)

plot settings

09A

en

v

elope cur

ve

• en

v.

cur

v

e

 + F

A

C

• en

v.

cur

v

e+ map

.

recor

d cur

ve

09B

• single cur

ve

• cyclic

no.

of

decimals

lo

w output limit

• off

• on

fix

ed current

• off

• on

fix

ed current

4 mA

output current

x.xx mA

sim

ulation

• sim.

off

• sim.

le

v

el

• sim.

v

olume

• sim.

current

sim

ulation v

alue

customer unit

see tab

le

customet unit

see tab

le

• hor

iz

ontal cyl.

• man

ual

• semi-automatic

• tab

le on

0C

ta

g No.

serial n

u

mber

pr

software No.

displa

y f

o

rm

at:

Vxx.yy

.zz.prot

software No.

custody tr

ansf

er

distance unit

• m • ft • mm • inch

do

wnload mode

• par

ameters only

• par

am.+ map

.

• mapping only

system

parameter

s

• X • X.X • X.XX • X.XXX • X.XXXX

xx:

HW

-v

ersion

yy:

SW

-v

ersion

zz:

SW

-re

vision

prot:

protocol name

i.e

.:

V01.01.00HAR

T

softw

are v

ersion 2.0

SM09F/00/05.02

retur

n to

g

roup selection

retur

n to

g

roup selection

retur

n to

g

roup selection

retur

n to

g

roup selection

retur

n to

g

roup selection

retur

n to

g

roup selection

retur

n to

g

roup selection

retur

n to

g

roup selection

retur

n to

g

roup selection

6:

ft3

7:

us gal

8:

i gal

9:

kg

10:

t

11:

lb

• English • Deutsch • F

rancais

• Espanol • Italiano • Neder

l.

jump to

matr

ix field 008

008

• le

v

e

l

(m, ft, in)

• ullage

(m, ft, in)

• e

xtended map

.

• mapping

• common

• too big • unkno

wn

09C

xx dB

100:

edit cust.matr

ix

200:

read customer / ser

vice matr

ix

measured

distance

[m]

measured

le

vel

[m]

300:

edit ser

vice matr

ix

33 998:

edit

WHG

33 999:

hardw

a

re loc

k

unloc

k parameter

to ser

vice matr

ix

• user specific

(s

)
0

*

*

= settings only f

or

WHG

• retur

n

meas.v

a

lue [m]

dip v

a

lue   [m]

k

eep        x

meas

.v

alue [m]

k

eep      x

dip v

a

lue [m]

dip tab

le

dip tab

le status

• tab

le on

• tab

le off

Summary of Contents for Micropilot S FMR 530

Page 1: ...personal repariert und gewartet werden Dabei sind die Ger tedokumentation die einschl gigen Normen die gesetzlichen Vorschriften und die Zertifikate zu beachten 0 1 2 0 1 2 Ex i Ger te Die Reparatur i...

Page 2: ...enrohr und Antennenkabel bilden eine Einheit und k nnen nicht getrennt werden Den Anschraubflansch vom Beh lter l sen und mit dem Antennenrohr aus dem Beh lter ziehen Durch Abschrauben der 4 Inbusschr...

Page 3: ...deren Verh ltnissen auch eine andere Ausrichtung besser sein Ausrichtung im Bypass verl ngerter Markierungspunkt steht 90 zum Zulauf gilt auch f r Hornantenne 90 Beh lter Bypass Ausrichtung im Schwall...

Page 4: ...eset auf die Werkseinstellungen r ckzusetzen In der Diagnose Ebene im Feld 0A3 die Zahl 333 eingeben Gegen unbeabsichtigtes ndern der eingestellten Ger tedaten sollte die Parametrierung verriegelt wer...

Page 5: ...Punkt Auswahl Messwert 00 000 12 ton 13 m 14 ft 15 mm 16 inch 17 none Kommunikations adresse 0 15 wenn 0 dann Multidropfunktion Stromausgang auf 4 mA fixiert aktueller Fehler letzter Fehler l sche le...

Page 6: ...hen edge parameter dB cust map valid not active active trig fail count fact map valid not active active module frequen MHz envelope energy dB present edge parameter dB Mapping Edge First echo Tank bot...

Page 7: ...tes have to be observed 0 1 2 0 1 2 Ex i devices The repair has to be performed such that the voltage isolation of the Ex ia circuits against ground is maintained If required a test can be performed w...

Page 8: ...tank together with the antenna pipe The flange can be separated from the antenna pipe by removing the 4 Allen screws AF 5 UNI flange The parabolic antenna with antenna pipe and antenna cable are one c...

Page 9: ...ience However under certain circumstances another alignment can be better Alignment in bypass marker point is offset to T s by 90 also applies to horn antenna 90 tank bypass Alignment in stilling well...

Page 10: ...nk It is recommended to reset the instrument to the factory settings before the calibration enter 333 in field 0A3 of the diagnostics level The configuration should be locked against unwanted changes...

Page 11: ...0 12 ton 13 m 14 ft 15 mm 16 inch 17 none communication address 0 15 if 0 then multidrop function current output fixed at 4 mA present error previous error clear last error keep erase reset x for rese...

Page 12: ...edge parameter dB cust map valid not active active trig fail count fact map valid not active active module frequen MHz envelope energy dB present edge parameter dB mapping edge first echo tank bottom...

Reviews: