8702
34562
PowerOn (or state
'Switched On') not
allowed
Reaction 2: Downramp /
apply brake / de-energize..
FE00
65024
Exception 00 DSP-
System
Switch-off of the current
immediately (without ramp),
application of the brake,
output error number, system
restart (software-reset).
FE01
65025
Exception 00 DSP-
System
Switch-off of the current
immediately (without ramp),
application of the brake,
output error number, system
restart (software-reset).
FE02
65026
Exception 02 DSP-
System
Switch-off of the current
immediately (without ramp),
application of the brake,
output error number, system
restart (software-reset).
FE04
65028
Exception 04 DSP-
System
Switch-off of the current
immediately (without ramp),
application of the brake,
output error number, system
restart (software-reset).
FE06
65030
Exception 06 DSP-
System
Switch-off of the current
immediately (without ramp),
application of the brake,
output error number, system
restart (software-reset).
FE08
65032
Exception 08 DSP-
System
Switch-off of the current
immediately (without ramp),
application of the brake,
output error number, system
restart (software-reset).
FE0A
65034
Exception 0A DSP-
System
Switch-off of the current
immediately (without ramp),
application of the brake,
output error number, system
restart (software-reset).
FF01
65281
No object with this
index available
Reaction 1: Downramp actual
speed; remain in position
control state.
FF02
65282
No object with this
subindex available
Reaction 1: Downramp actual
speed; remain in position
control state.
FF03
65283 Object is "read only"
Reaction 1: Downramp actual
speed; remain in position
control state.
FF04
65284
Object cannot be
read
Reaction 1: Downramp actual
speed; remain in position
control state.
The error may occur if there is an older bootload version in a
fieldbus module and if the fieldbus firmware is to be actualized
again after an update without PowerOff/PowerOn.