PROGRAMMING
3-17
Revised January 2001
Part No. 001-7780-501
SMARTNET/SmartZone System Talk Groups
Screen
and program unique talk group information. This
screen is shown on the next page, and the parameters it
programs are as follows:
Talk Group - Selects the talk group to program. This
is the actual ID of the talk group. Talk groups are
added or deleted by clicking the Add TG or Delete
TG button (see following). Talk groups are assigned
to channels on the channel screen (see Section
3.6.9).
- Clicking this button displays a dialog
box that adds a new talk group. The alias (alphatag)
of up to 8 characters is entered, and the new group
is then added after the others that are already set up.
Each SMARTNET/SmartZone system can be
programmed with up to 256 talk groups.
- Clicking this button deletes the
currently selected talk group (the one displayed in
the “Talk Group” box).
Failsoft Channel
Enable - Enables a failsoft channel on the talk group
if a controller failure occurs (see Section 2.5.11).
Disable - The failsoft mode is not entered if the
controller fails.
Tx/Rx Frequency - Programs the failsoft channel
frequency if “Enabled” is checked.
3.6.6 SMARTNET/SMARTZONE SYSTEM
EMERGENCY SETTINGS SCREEN
The SMARTNET/SmartZone Emergency
Settings screen and the parameters it programs are as
follows:
Emergency Call
Enable - When the Emergency option switch and
then the PTT switch are pressed, an emergency
group call is transmitted.
Disable - An emergency group call is not
authorized.
Emergency Hot Mic
Enable - When an emergency alarm is generated and
the emergency alarm acknowledgment received, the
emergency mode is automatically entered and trans-
mitting begins for the time specified by the Tx Period
parameter (see following).
Disable - Automatic transmissions do not occur.
Tx Period - Defines the period during which trans-
missions occur with the microphone audio unmuted
(without user intervention). Times of 10-120 seconds
in 10-second steps can be selected.
Emergency Alarm
Disabled - No emergency signal is sent when the
user presses the Emergency option switch.