19
8.
REPLACEMENT PARTS / ACCESSORIES
8.1. Order Code Replacement Sensor
EE772-R-
Hardware Configuration
Model
compact ri-le
direction od flow right to left
A
compact le-ri
direction od flow left to right
B
remote probe
C
Working range
high
(0,5...200 Nm/s) or (100...39370 ft/min)
H1
Measuring pipe -
DN40
N040
diameter
DN50
N050
DN65
N065
DN80
N080
Mounting
MultiController
M
MultiController with hot tap valve
W
Plug
1)
cable gland
A
1 plug for power supply and outputs
Q
EE772-R-AH1N065MQ
Model:
Compact ri-le
Working range:
high
Measuring pipe - diameter:
DN65
Mounting: MultiController
Plug:
1 plug for power supply and outputs
EE772-R-CH1N065M
Model:
remote probe
Working range:
high
Measuring pipe - diameter:
DN65
Mounting: MultiController
Order Example
Order Example
1) only for model A and B