11
70
(2.8“)
Cable length acc. to order code
Single-sided screw connection
1/2" ISO or NPT
wall mounting temperature - xT model
Remote sensing probe temperature
2.5 Humidity probe working range
The grey area shows the allowed measurement range for the humidity sensor. Although
working points that lie outside of this range do not lead to the destruction of the element,
the specified measurement accuracy cannot be guaranteed, however.
Relative humidity [% rel. hum.]
Temperature [°C]
179
(7“)
60
(2.4“)
151
(5.9“)
98
(3.9“)
Ø6
(0.24“)
150
(6“)
2.6 Dewpoint measurement in natural gas
Valid only for EE300Ex-HT6S...Gx (Special option for natural Gas application)
The accuracy of the dewpoint measurement is affected by the working pressure. The actual
working pressure has to be set with the configuration software.
Menu item "Configuration" --> "Parameters"
Factory setting: 1013.25 mbar
2.7 Measurement of moisture in oil
Besides measurement in the air, the EE300Ex can be employed for measurement of both
absolute water content (x) in ppm or relative water activity (aw) in oils.
The USA and Canada approval is valid for air and gas measurement only.
Summary of Contents for EE300E Series
Page 26: ...34 10 EC Declaration of Conformity...
Page 27: ...35 11 IECEX CERTIFICATE OF CONFORMITY COC...
Page 28: ...36...
Page 29: ...37...