The steps recommended by the manufacturer for installation, inspections and maintenance work must
be observed and carried out for the safety of the user and for the functionality of the equipment.
Unauthorized product modification leads to loss of all warranty claims. This may be accomplished only
with an explicit permission of E+E Elektronik
®
!
1.2.3 Mounting, Start-up and Operation
The EE260 humidity and temperature probe for meteorological applications has been produced under
state of the art manufacturing conditions, has been thoroughly tested and has left the factory after
fulfilling all safety criteria. The manufacturer has taken all precautions to ensure safe operation of the
device. The user must ensure that the device is set up and installed in a manner that does not have a
negative effect on its safe use. The user is responsible for observing all applicable safety guidelines,
local and international, with respect to safe installation and operation on the device. This user manual
contains information and warnings that must be observed by the user in order to ensure safe operation.
Mounting, start-up, operation and maintenance of the device may be performed by qualified staff
only. Such staff must be authorized by the operator of the facility to carry out the mentioned activities.
The qualified staff must have read and understood this user manual and must follow the instructions
contained within.
All process and electrical connections shall be thoroughly checked by authorized staff before putting
the device into operation.
Do not install or start-up a device supposed to be faulty. Make sure that such devices are not
accidentally used by marking them clearly as faulty.
A faulty device may only be investigated and possibly repaired by qualified, trained and authorized
staff. If the fault cannot be fixed, the device shall be removed from the process.
Service operations other than described in this user manual may only be performed by the
manufacturer.
1.3 Environmental Aspects
Products from E+E Elektronik® are developed and manufactured in compliance with all relevant
environmental protection requirements. Please observe local regulations for the device disposal.
For disposal, the individual components of the device must be separated according to local recycling
regulations. The electronics shall be disposed of correctly as electronics waste.
2 Scope of Supply
EE260 – Heated Humidity and Temperature Probe for Meteorological Applications
Inspection certificate according to DIN EN 10204-3.1
Quick guide
3 Product Description
3.1 General
The EE260 probe is optimized for accurate and reliable relative humidity (RH) and temperature (T)
measurement in meteorology and demanding outdoor applications.
Mounted in its upright position, the air first passes over EE260‘s Pt100 temperature sensing element,
then over the heated probe shaft and over the heated humidity sensing element. This dual heating
system prevents condensation or icing of the RH sensing element, on the probe head and on the filter
cap. This leads to short response times and fast recovery as well as to precise RH measurement even
under continuously high humidity and condensing conditions.