E+E Elektronik EE260 User Manual Download Page 4

4

User Manual EE260 Heated Humidity and Temperature Probe for Meteorological Applications

1  General

This user manual serves for ensuring proper handling and optimal functioning of the device. The user 

manual shall be read before commissioning the equipment and it shall be provided to all staff involved 

in transport, installation, operation, maintenance and repair. The user manual may not be used for the 

purposes of competition without the written consent of E+E Elektronik® and may not be forwarded to 

third parties. Copies may be made for internal purposes. All information, technical data and diagrams 

included in these instructions are based on the information available at the time of writing.

Disclaimer

The manufacturer or his authorized agent can be only be held liable in case of willful or gross 

negligence. In any case, the scope of liability is limited to the corresponding amount of the order issued 

to the manufacturer. The manufacturer assumes no liability for damages incurred due to failure to 

comply with the applicable regulations, operating instructions or the specified operating conditions. 

Consequential damages are excluded from the liability.

1.1  Explanation of Symbols

This symbol indicates safety information.

It is essential that all safety information is strictly observed. Failure to comply with this information can 

lead to personal injuries or damage to property. E+E Elektronik® assumes no liability if this happens.

This symbol indicates instructions.

The instructions shall be observed in order to reach optimal performance of the device.

1.2  Safety Instructions

1.2.1  General Safety Instructions

 

ƒ

The device and mainly the filter cap shall not be exposed to unnecessary mechanical stress.

 

ƒ

When replacing the filter cap make sure not to touch the sensing elements.

 

ƒ

The device must be operated with the filter cap on at all times.

 

ƒ

Installation, electrical connection, maintenance and commissioning shall be performed by qualified 

personnel only.

 

ƒ

Use the EE260 only as intended and observe all technical specifications.

 

ƒ

Do not use EE260 in explosive atmosphere or for measurement of aggressive gases.

 

ƒ

Do not apply the nominal voltage to the RS485 data lines.

 

ƒ

This device is not appropriate for safety, emergency stop or other critical applications where device 

malfunction or failure could cause injury to human beings.

1.2.2  Intended Use

The EE260 is intended for the humidity (RH) and temperature (T) measurement in meteorology. It is 

compatible with rotation symmetric radiation shields (available as accessory HA010511). By means of 

a mounting clip (accessory HA010227) the EE260 can be pole/wall mounted, e.g. for deployment in 

weather huts / Stevenson screens.

The use of the EE260 in any other way than described in this manual bears a safety risk for people and 

the entire measurement installation and is therefore not allowed. 

The manufacturer cannot be hold responsible for damages as a result of incorrect handling, installation, 

and maintenance of the equipment.

In order to avoid damage to the instrument or health hazards, the measuring equipment must never be 

manipulated with tools that are not specifically described in this manual.

The sensor may only be utilized in accordance with the conditions defined in the technical data. 

Otherwise, measurement inaccuracies will occur and equipment failures cannot be ruled out.

Summary of Contents for EE260

Page 1: ...BA_EE260 v1 1 Modification rights reserved User Manual EE260 Heated Humidity and Temperature Probe for Meteorological Applications...

Page 2: ...equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmf...

Page 3: ...and Adjustment 9 5 1 EE PCS Product Configuration Software 9 5 2 Digital Interface RS485 with Modbus RTU Protocol 9 5 3 Modbus Register Map 11 5 4 Modbus Message Example 12 6 Maintenance and Service...

Page 4: ...Safety Instructions 1 2 1 General Safety Instructions The device and mainly the filter cap shall not be exposed to unnecessary mechanical stress When replacing the filter cap make sure not to touch t...

Page 5: ...connections shall be thoroughly checked by authorized staff before putting the device into operation Do not install or start up a device supposed to be faulty Make sure that such devices are not acci...

Page 6: ...umidity related parameters Dew point temperature Td Frost point temperature Tf Wet bulb temperature Tw Water vapour partial pressure e Mixing ratio r Absolute humidity dv Specific enthalpy h The RH an...

Page 7: ...cho Puls 25 18 25 Fig 2 Dimensions in mm of optional radiation shield ordering code HA010511 3 3 Electrical Connection Pin number Function Wire colors for accessories Connection cable HA010322 23 24 2...

Page 8: ...he HA010511 data sheet for more information Fig 3 EE260 mounted within the optional radiation shield HA010511 4 2 Wall Mount Pole Mount The probe may be installed on a wall or a pole with the help of...

Page 9: ...nd install it on the PC 2 Connect the EE260 to the PC using the Modbus configuration adapter and the EE260 configuration cable 3 Start the EE PCS software 4 Follow the instructions on the EE PCS openi...

Page 10: ...ction code 0x06 Slave ID Modbus address 1 0x00 Modbus protocol settings3 2 0x01 1 Register number starts from 1 2 Protocol address starts from 0 3 For Modbus protocol settings see Application Note Mod...

Page 11: ...d C 1105 0x450 F 1107 0x452 K 1147 0x47A Wet bulb temperature Tw C 1109 0x454 F 1111 0x456 K 1145 0x478 Absolute humidity dv g m 1113 0x458 gr ft 1115 0x45A Mixing ratio r g kg 1121 0x460 gr lb 1123 0...

Page 12: ...sure above water ew mbar 100 4111 0x100E psi 100 4112 0x100F Saturation vapor pressure above ice ei mbar 100 4113 0x1010 psi 100 4114 0x1011 Ice bulb temperature Ti C 100 4119 0x1016 F 100 4120 0x1017...

Page 13: ...the user see the E E cleaning instructions 6 2 Filter Replacement In a dusty or polluted environment it might be necessary to replace the filter cap or the filter membrane respectively once in a whil...

Page 14: ...emperature Please contact your sales representative for assistance Please note When the calibration adjustment procedure with the help of EE PCS starts both heating modes of the EE260 are disabled aut...

Page 15: ...ure with the help of EE PCS starts both heating modes of the EE260 are disabled automatically if they have on status At the end of the procedure the heating comes back to on automatically The temperat...

Page 16: ...EE260 configuration cable1 HA011020 E E Product Configuration Software Download www epluse com configurator EE PCS M12x1 cable connector 8 pole socket HA010704 Connection cable 8 pole M12x1 socket fre...

Page 17: ...ID 235 General Supply voltage 7 30 V DC Power consumption typ 300 mW 25 mA 12 V DC heating included Electrical connection M12x1 8 poles stainless steel 1 4404 Filter PTFE membrane stainless steel body...

Page 18: ...lin 69130 Ecully Tel 33 4 74 72 35 82 E mail info epluse fr E E Elektronik Germany Sch ne Aussicht 8 C 61348 Bad Homburg Tel 49 6172 13881 0 E mail info epluse de E E Elektronik Italy Via Alghero 17 1...

Reviews: