12
User Manual EE260 Heated Humidity and Temperature Probe for Meteorological Applications
INTEGER 16 bit:
Parameter
Unit
Scale
3)
Register number
1)
[Dec] Register address
2)
[HEX]
Read register: function code 0x03 / 0x04
Temperature T
°C
100
4002
0xFA1
°F
50
4003
0xFA2
°K
50
4005
0xFA4
Relative humidity RH, Uw
% RH
100
4011
0xFAA
Water vapour partial pressure e
mbar
10
4051
0xFD2
psi
1000
4052
0xFD3
Dew point temperature Td
°C
100
4053
0xFD4
°F
100
4054
0xFD5
°K
100
4074
0xFE9
Wet bulb temperature Tw
°C
100
4055
0xFD6
°F
100
4056
0xFD7
°K
100
4073
0xFE8
Absolute humidity dv
g/m³
10
4057
0xFD8
gr/ft³
10
4058
0xFD9
Mixing ratio r
g/kg
10
4061
0xFDC
gr/lb
10
4062
0xFDD
Specific enthalpy h
kJ/kg
1
4063
0xFDE
ft lbf/lb
1
4064
0xFDF
BTU/lb
1
4065
0xFE0
Frost point temperature Tf
°C
100
4066
0xFE1
°F
100
4067
0xFE2
°K
100
4075
0xFEA
Volume concentration Wv
ppm
0.1
4076
0xFEB
%
1000
4078
0xFED
‰
100
4079
0xFEE
Saturation vapor pressure
above water ew
mbar
100
4111
0x100E
psi
100
4112
0x100F
Saturation vapor pressure
above ice ei
mbar
100
4113
0x1010
psi
100
4114
0x1011
Ice bulb temperature Ti
°C
100
4119
0x1016
°F
100
4120
0x1017
°K
50
4121
0x1018
Specific humidity qv
g/kg
10
4124
0x101B
gr/lb
10
4125
0x101C
1) Register number starts from 1
2) Register address starts from 0
3) Examples: For scale 100, the reading of 2550 means a value of 25.5. For scale 50, the reading of 2550 means a value of 51.
5.4 Modbus Message Example
Example of Modbus RTU command for reading the temperature (float value) T = 24.625015 °C
from the register 0x3EA
Device EE260; slave ID 235 [0xEB]
Reference document, chapter 6.3:
www.modbus.org/docs/Modbus_Application_Protocol_V1_1b3.pdf
See Application Note Modbus AN0103 (available on
)
Modbus ID
address
Function
code
Starting
address Hi
Starting
address Lo
No. of
register Hi
No. of
register Lo
CRC
Request [Hex]:
EB
03
03
EA
00
02
F3
71
Modbus ID
address
Function
code
Byte
count
Register 1
value Hi
Register 1
value Lo
Register 2
value Hi
Register 2
value Lo
CRC
Response Hex]:
EB
03
04
00
08
41
C5
C0 3C