PRODUCT
Product Features
E.C.A. Felis condensing boilers are designed to accomodate the central heating needs in a safe and
comfortable way. Felis boilers should be connected to a heating circuit that is suitable for the capacity
and power level of the boiler. Felis condensing boilers works with natural gas.
Innovative design that ensures ease of service and maintenance. The width and heigth dimensions
staying same through all capacities enables to use the installation space efficiently. Its curved panel
design has a elegant appearance. Screen panel cover provides protection from the environmental
hazards of the boiler room conditions.
Functions and the safety of the appliance is provided by the control mainboard. Mainboard controls
the gas valve, blower and circulation pump. Flame in the burner is always checked via ionization
electrode and can be observed by the LEDs and the screen symbols on the panel.
Control panel is designed ergonomically and easy to use. With a wide LCD screen, Felis condensing
boiler provides a control system that supports multiple languages with descrpitive menus. White
backlighted LCD screen shows information about working mode, CH and DHW set points, real time
temperatures, fault codes with descriptions and water pressure.
Safety measurements on the appliance assures both your safety and the safety of the appliance.
These safety measurements are as follows;
• Flame Loss Safety
• CH Circuit Overheating Safety (90 °C)
• Flue Gas Overheating Safety (95 °C)
• Boiler Overheating Safety (105 °C)
• High Water Pressure Safety (6 bar)
• Low Water Pressure Safety (0,8 bar)
• Low Voltage Safety (170 VAC)
• Frost Protection (Electrical supply to the boiler must be maintened in order to frost protection to
work)
• Automatic Air Purger
• Annual Maintenance Reminder
4
CAUTION:
Any person who is not capable in physical, sensory or
emotional aspect (including children) shall not operate the appli-
ance without observation.
CAUTION:
This appliance is not suitable for use by the people
who is not capable in physical, sensory or emotional aspects
without observation and information of the people responsible
for the appliance. Children should not tamper with the device.
Any unauthorized usage that does not fit the purpose of the
device could cause danger to the people and the environment.
Summary of Contents for FELIS FL 100 HM
Page 1: ...FELIS WALL HUNG CONDENSING BOILER FELIS FL 50 65 100 125 150 HM INSTALLATION AND USER MANUAL ...
Page 2: ......
Page 10: ...7 Felis 65 Figure 2b Felis 65 Detailed Drawings ...
Page 11: ...8 Felis 100 125 150 Figure 2c Felis 100 125 150 Detailed Drawings ...
Page 13: ...Figure 3 Electronic Board Circuit Diagram 10 Electrical Board Circuit Diagram ...
Page 18: ... d d l Figure 7 Flue Types 15 I I I I ...
Page 30: ...27 ...
Page 31: ...28 ...
Page 32: ...29 ...
Page 33: ...30 ...
Page 40: ......
Page 46: ......