11.2
– LCD Screen
LCD screen display icons described here below.
Flame Icon
Parameter Setting
Indicator
Reset
Temperature
Set
Centr al H eating
On
Domestic Water
Heating
Pressure
Display
Figure
19
. Description of Symbols
10.3- Operation Modes:
10.3.1- Standby Mode (Off Mode):
It is the mode in which the device can be set to standby mode. In
this mode, central heating and domestic water heating demands cannot be met.
10.3.2- Summer Mode:
In this mode, the device does not perform central heating but does domestic
water heating if there is a demand.
10.3.3- Winter Mode:
In this mode, the device performs both central heating and domestic water
heating if there is a demand.
10.3.4- Domestic Water (DHW) Comfort Mode:
In this mode, water in the heat exchanger is kept at
the domestic water set temperature and thus can be supplied at the desired temperature when the
domestic water is turned on. While heating the water in the heat exchanger in comfort mode, tap icon
on the screen flashes twice a second to inform the user that Comfort Mode
heating is in progress. At the
same time, “CO” letters are shown on the pressure indicator field.
Comfort mode can be activated by
pressing K5 and K6 buttons together for 5 seconds when the device is in ECO mode.
10.3.5- Domestic Hot Water (DHW) Eco Mode:
At the times that hot water demand is not expected
(e.g. holidays etc.) or more economic use is preferred, ECO mode prevents the water in the exchanger
to be heated and provides a more economic use of the device. When the ECO Mode is active “EC”
letters are shown on the pressure indicator field. ECO mode can be activated by pressing K5 and K6
buttons together for 5 seconds when the device is in Comfort mode.
10.3.6- No-Frost Mode:
During the winter season, when the installation water temperature falls below
6
℃
, the no-frost mode function is activated and the device continues to operate until the installation
water outlet temperature rises to 15
℃
. In order for the freeze protection function to work, the following
conditions must be checked and ensured by the customer:
CAUTION:
Do not press the RESET button while the device is in AP