Low Water Pressure
The water pressure parameter FP11 is at a low level.
This error is displayed if the water pressure is less than FP11/10
bar.
When the water pressure is greater than (FP11/10+0.4 bar), the
error is automatically cleared.
F
37
Outdoor Temperature
Sensor Error
This error is displayed if the outdoor temperature sensor is short or
open circuit, or damaged. Domestic water and central heating
demands are stopped. When this error is cleared, normal
operation begins.
F
39
High Water Pressure
The water pressure parameter FP12 is at a high level.
This error is displayed if the water pressure is greater than FP12/10 bar.
When the water pressure is less than (FP12/10-0.2 bar), the error is
automatically cleared.
F
40
Water Pressure Sensor
Error
This error is displayed if the pressure sensor is short or open
circuit, or damaged. When this error is cleared, normal operation
begins.
F
47
Solar Boiler Tank
Temperature Sensor
Error
This error is displayed if the solar boiler tank temperature sensor is
short or open circuit, or damaged. Domestic water and central
heating demands are stopped. When this error is cleared, normal
operation begins.
F
50
Solar Panel Temperature
Sensor (PT1000) Error
This error is displayed if the solar panel temperature sensor
(PT1000) is short or open circuit, or damaged. Domestic water and
central heating demands are stopped. When this error is cleared,
normal operation begins.
F
51
CH flow NTC probe -
CH return NTC probe
swap test failed
If CH flow NTC probe, CH return NTC probe swap test fails, this
error is given. RESET action is required in order to reset the
failure.
E80