![Dynon Avionics FlightDEK-D180 Installation Manual Download Page 63](http://html1.mh-extra.com/html/dynon-avionics/flightdek-d180/flightdek-d180_installation-manual_2550925063.webp)
EMS
Configuration
1400-1800
and
5500-5800 RPM in YELLOW
1800-5500 RPM in GREEN
At 0 RPM, the LOW RPM ALARM is inhibited. When RPM advances above 0, the LOW RPM
ALARM is inhibited for 10 seconds. The HIGH RPM ALARM is always active.
OIL TEMP Gauge for Rotax 912:
When OIL TEMP < 190ºF, the OIL TEMP gauge displays these ranges:
100-120 and 230-266ºF in YELLOW
120-190ºF in GREEN
if OIL TEMP has been above 190ºF “more recently” than OIL TEMP
was below 120ºF;
otherwise 120-190ºF is displayed in BLACK OUTLINED IN WHITE
190-230ºF in GREEN
266-280ºF in RED.
When OIL TEMP is > 190ºF, the OIL TEMP gauge will display
different
ranges:
100-120
and
230-266ºF in YELLOW
120-230ºF in GREEN
266-280ºF in RED
ENGINE TYPE: OTHER
For all other engine types, select OTHER. Currently, the FlightDEK-D180 calculates percent
power only for normally-aspirated Lycoming or Continental engines. Dynon Avionics will
consider adding more engine types to our percent power calculations. If your engine is not
currently supported and you would like to see it considered for possible inclusion, please send
your engine’s power chart to:
Fuel Level Calibration
Prior to calibrating your fuel tanks, ensure that you have made the correct fuel level sensor type
selection as described on page 6-13.
Enter the EMS menu by pressing any button
below an EMS main page and pressing MORE >
SETUP > MORE > FUEL. You are presented
with the screen shown below. The menu reflects
the number of fuel tanks selected in the Global
Parameters Setup, as described on page 6-3. If y
do not see the correct number of tanks here, go
back to the GLOBAL section of the SETUP menu
and set the correct number of tanks.
ou
Begin with empty tanks and be ready to fill them to capacity with an accurate way of adding fuel
in defined increments (i.e. a standard gas pump gauge). Orient your plane into level flight
attitude, and repeat the following steps for each tank you wish to calibrate.
FlightDEK-D180 Installation Guide
6-5
Summary of Contents for FlightDEK-D180
Page 2: ......
Page 4: ......
Page 18: ......
Page 28: ...Transducer Installation 3 10 FlightDEK D180 Installation Guide...
Page 38: ......
Page 58: ......
Page 78: ......
Page 81: ...DSAB Configuration FlightDEK D180 Installation Guide 7 3...
Page 116: ......
Page 131: ...Appendix FlightDEK D180 Installation Guide 9 15...
Page 132: ...Appendix 9 16 FlightDEK D180 Installation Guide...