-17-
3.4 PERFORMANCE CHARACTERISTICS
3.4.1 ACCURACY
Accuracy is defined as combined error expressed as a percentage of full scale (% F.S.) output based
on the following standard configurations/conditions:
1) Best Straight Line % F.S. as per ISA-37.3
2) +20
°
C ambient electronics
*Consult factory for non-standard configurations.
Model
Range
Accuracy (% of
FS)
2280
15 – 72,500 PSI
+/- 0.50
2281
15 – 72,500 PSI
+/- 0.25
2282
5 – 10,000 PSI
+/- 0.15
3.4.2 RESOLUTION
±0.035% full scale @ 50% F.S. (average resolution)
3.4.3 REPEATABILITY
± 0.10% of full scale
3.4.4 OVERLOAD PRESSURE (MAX PRESSURE WITHOUT INVALIDATING SPECIFIED ACCURACY)
Model
Pressure
5-25 psi, w/ overload stop
10 x range
50-750 psi, w/ overload stop
5 x range
250 – 30,000 psi
1.5 x range
Greater than 30,000 psi
1.2 x range
3.4.5 BURST PRESSURE
Model
Pressure
250 psi
10 x range
500-3,000 psi
5 x range
5,000 – 10,000 psi
3 x range
15,000 – 30,000 psi
2.5 x range
40,000 – 60,000 psi
1.5 x range
3.4.6 FREQUENCY RESONSE
20 Hz [-3db]