The PT46XDN can be readily connected to the DeviceNet bus using the optional connector and cable
assembly or a customer-supplied connector and cable. It is important to adhere to proper DeviceNet wiring
practices. The DeviceNet Technical Overview available from the Open DeviceNet Vendors Association
(
www.odva.org
) provides additional information on DeviceNet physical layer topologies including cable
types, trunk and drop lengths, and terminating resistors.
It is recommended that all wiring be validated using a media checker to identify potential media problems,
e.g. shorts, opens, excessive cable length, and crossed connections.
5.6
5.6
5.6
5.6
5.6
D
D
D
D
D
EVICE
EVICE
EVICE
EVICE
EVICE
N
N
N
N
N
ET
ET
ET
ET
ET
C
C
C
C
C
ONNECTOR
ONNECTOR
ONNECTOR
ONNECTOR
ONNECTOR
W
W
W
W
W
IRING
IRING
IRING
IRING
IRING
The DeviceNet Pressure Transmitter uses the standard DeviceNet Micro DIN 5-pin connector. The
connections are as follows:
Cable Leads
To
Connector Pin
Black
-V
3
Blue
CAN-L
5
Bare
Drain
1
White
CAN-H
4
Red
+V
2