3.3 Performance characteristics
(xDT4Xx x-xx-xxx-xx)
3.3.1 Accuracy
(Linearity and hysteresis at T = constant)
xDT42x x
± 0,5 % of full scale
(35 bar and 50 bar
± 1 % of full scale)
xDT46x x
± 1 % of full scale
3.3.2 Repeatability
xDT42x x
± 0,1 % of full scale
(35 bar and 50 bar
± 0,2 % of full scale)
xDT46x x
± 0,2 % of full scale
3.3.3 Resolution
infinite
3.4 Mechanical configurations
(XDT4xX x-xx-xxx-xx)
MDT4x0, LDA 415
stem version
MDT4x2
rigid stem and flexible stem
TDT432/463
combined pressure and
temperature
measurement
MDT435/467
transducer for limited
installation space
3.5 Pressure side connection
(xDT4xx x-XX-xxx-xx)
½ = ½” 20 UNF 2A
M18 = M18 x 1,5
3.6 Pressure ranges
(xDT4xx x-xx-XXX-xx)