Dynex PF500-10 Service Instructions Manual Download Page 6

6

Minimum Inlet Pressure

Operating Speed

Pump Models

1200 rpm

1500 rpm

1800 rpm

2400 rpm

2800 rpm

3600 rpm

psi

bar

psi

bar

psi

bar

psi

bar

psi

bar

psi

bar

  Fixed Displacement Pumps:

PF501 and PF504

0

0

0

0

0

0

0

0

0

0

5

0,4

PF507

0

0

0

0

0

0

0

0

5

0,4

   10

   0,7

PF510

0

0

0

0

0

0

0

0

   10

   0,7

   15

�  1,0

PF1002

0

0

0

0

0

0

0

0

0

0

5

0,4

PF1003 and PF1004

0

0

0

0

0

0

0

0

5

0,4

   10

   0,7

PF1005 and PF1006

0

0

0

0

0

0

   10

   0,7

PF1007 and PF1008

0

0

0

0

0

0

   10

   0,7

PF2007

0

0

0

0

0

0

3

0,2

5

0,4

�–

PF2008

0

0

0

0

0

0

5

0,4

PF2009

0

0

0

0

0

0

3

0,2

5

0,4

PF2012

0

0

0

0

0

0

5

0,4

PF2000 Series (Special Mounting)

0

0

0

0

0

0

5

0,4

PF3011

0

0

0

0

0

0

     ➃

     ➃

   10

   0,7

PF3015

0

0

0

0

3

0,2

     ➃

     ➃

PF3017

0

0

0

0

5

0,4

     ➃

     ➃

PF3021

0

0

0

0

3

0,2

     ➃

     ➃

PF3024

0

0

0

0

5

0,4

     ➃

     ➃

PF4011

0

0

0

0

0

0

5

0,4

PF4016

0

0

0

0

0

0

5

0,4

PF4018

0

0

0

0

5

0,4

  10

   0,7

PF4020

0

0

5

0,4

  10

   0,7

  15

   1,0

PF4203 and PF4205

0

0

0

0

0

0

PF4208

0

0

0

0

5

0,4

PF4209 and PF4210

0

0

5

0,4

10

0,7

PF6023

0

0

5

0,4

10

0,7

PF6033

0

0

10

0,7

15

1,0

PF6046

0

0

5

0,4

10

0,7

PF6054

0

0

5

0,4

5

0,4

10

0,7

PF6070

0

0

5

0,4

10

0,7

     ➄

     ➄

PF6080

5

0,4

5

0,4

10

0,7

     ➄

     ➄

  Fixed Displacement Pumps for Water-Based Fluids:

All PF1300 Models

0

0

0

0

0

0

PF4303 and PF4304 

0

0

0

0

0

0

PF4305 and PF4306

0

0

0

0

0

0

PF4308

0

0

0

0

5

0,4

PF4309

0

0

5

0,4

10

0,7

PF4310 and PF4312

0

0

5

0,4

15

1,0

  Variable Delivery Pumps:

PV4018 and PV4026

0

0

5

0,4

5

0,4

10

0,7

PV4033

0

0

5

0,4

5

0,4

PV6054

0

0

5

0,4

5

0,4

10

0,7

PV6070

0

0

5

0,4

10

0,7

     ➄

     ➄

PV6080

5

0,4

5

0,4

10

0,7

     ➄

     ➄

  Pressure Compensated Pumps:

PV4000 Series

0

0

5

0,4

5

0,4

PV6046 and PV6054 

0

0

3

0,2

5

0,4

PV6070

3

0,2

8

0,6

10

0,7

PV6089 

5

0,4

10

0,7

15

1,0

  Values shown are based on fluid viscosity of 100 SUS (20 cSt) mineral oil, except pumps for water-based fluids as indicated.

  Inlet pressures higher than 10 psig (0,7 bar) require a high-pressure shaft seal. 

  Minimum inlet pressure: 5 psi (0,4 bar) at 2200 rpm.

  Minimum inlet pressure for Model PF3011: 5 psi (0,4 bar) at 2200 rpm and 7 psi (0,5 bar) at 2500 rpm; for Models PF3015 and PF3021: 7 psi (0,5 bar) at 2200 rpm 

and 10 psi (0,7 bar) at 2500 rpm maximum speed; for Models PF3017 and PF3024: 10 psi (0,7 bar) at 2200 rpm maximum speed.

  Minimum inlet pressure for Models PF6070 and PV6070: 10 psi (0,7 bar) at 2300 rpm maximum speed; for Model PF6080 and PV6080: 15 psi (1,0 bar) at 2200 rpm 

maximum speed.

  Values shown are based on fluid viscosity of 33 SUS (1,9 cSt) water glycol fluid. Higher viscosity fluids may require pressurized inlet conditions then indicated.

  Values shown are based on fluid viscosity of 33 SUS (1,9 cSt) water glycol fluid. Higher viscosity fluids may require pressurized inlet conditions then indicated.

Summary of Contents for PF500-10

Page 1: ...each piston pumping chamber to direct flow from the inlet side of the pump to the pump outlet port During operation a fixed angle wobble plate rotates with the drive shaft The angled surface imparts...

Page 2: ...or beyond the optimum fluid viscosity range IMPORTANT Refer to Fluid Recommendations below Port Fitting Configurations 1 Dynex pumps are available with outlet ports suitable for use at various pressur...

Page 3: ...ck for correct circuit connections and leaks 4 Then run the pump at no load pressure all valves in an open neutral position for several minutes Check to be sure the pump does not leak or develop exces...

Page 4: ...resulting in fluid contamination it is important to drain and clean the reservoir all lines filter screens and all components Refill the system with new fluid This must be done to prevent immediate f...

Page 5: ...e that air is bled from pump case and inlet lines System Not Developing Pressure 1 Check possible causes listed above for Low Flow or No Pump Flow 2 Check the relief valve and any pres sure control va...

Page 6: ...0 0 0 0 PF4308 0 0 0 0 5 0 4 PF4309 0 0 5 0 4 10 0 7 PF4310 and PF4312 0 0 5 0 4 15 1 0 Variable Delivery Pumps PV4018 and PV4026 0 0 5 0 4 5 0 4 10 0 7 PV4033 0 0 5 0 4 5 0 4 PV6054 0 0 5 0 4 5 0 4...

Page 7: ...UMP COVER O RING COUPLING Typical S A E Straight Thread port connection Typical British Standard Pipe parallel fitting with shoulder port connection PUMP COVER COUPLING SEAL RING SHOULDER O RING PUMP...

Page 8: ...gdom Tel 44 0 1480 213980 FAX 44 0 1480 405662 E mail sales dynexhydraulics co uk USA Headquarters Dynex Rivett Inc 770 Capitol Drive Pewaukee WI 53072 U S A Tel 262 691 2222 FAX 262 691 0312 E mail s...

Reviews: