Dynex PF500-10 Service Instructions Manual Download Page 1

General Instructions: 

Checkball Piston Pumps

High Pressure Hydraulics

D

YNEX

SERVICE

INSTRUCTIONS

SERVICE GUIDELINES 

These instructions assume a basic understanding of standard 

hydraulic system installation, operating practices and mainte-

nance procedures.

Avoid Contamination

Contamination  is  detrimental  to  any  hydraulic  system. 

Absolute cleanliness is essential during servicing and installa-

tion to prevent foreign material from contaminating the pump 

and hydraulic system.

Identify the Pump

The pump nameplate is located on the flat surface between 

the inlet port and the mounting flange. See FIGURE 1.
This  stamped  metal  tag  includes  either  a  ten-digit  model 

number (i.e., PF2006-1808) or a descriptive model code (i.e., 

PF1002H-SXEA-22-10). The serial number, also stamped on 

the plate, can be helpful when communicating with the sales 

department.

Confirm Pump Capability

Refer  to  the  published  pump  specifications.  Exceeding  the 

performance recommendations will reduce operating life.
Contact the sales department for a review of any application 

which requires operating above rated pressures or flows, or 

beyond the specified speed range. 

Checkball  hydraulic  pumps  are  axial  piston  pumps,  which  use  two 

check  valves  in  each  piston  pumping  chamber  to  direct  flow  from 

the inlet side of the pump to the pump outlet port. During operation, 

a  fixed-angle  wobble  plate  rotates  with  the  drive  shaft.  The  angled 

surface imparts a reciprocating motion to the pistons, which move in 

and out of the bores in the stationary barrel.

Be Aware of Design Changes

Dynex reserves the right to change designs and specifications 

at any time without incurring any obligation. Contact the sales 

department if you have any questions about pump operating 

parameters, proper installation or operation.

INSTALLATION INSTRUCTIONS

Inlet Pipe/Hose Sizing

1.  Recommended maximum inlet fluid velocity is 4 feet per 

second (1,2 metres per second).

2.  Recommended maximum outlet fluid velocity is 30 feet 

per second (9,1 metres per second).

Inlet Conditions

1.  Failure to meet minimum inlet pressure requirements will 

result in reduced output flow.

 

IMPORTANT: Refer to the "Minimum Inlet Pressure" table 

on page 6.

2.  Inlet pressures higher than 10 psi (0,7 bar) require a high-

pressure shaft seal. On most Dynex pump models a high-

pressure seal is an option that must be specified. Refer to 

the published pump specifications.

FIGURE  1:  Typical  pump  showing  location  of  nameplate  and  shaft 

rotation  tag,  adjacent  to  inlet  port.  Rotation  is  indicated  only  on 

pumps which are unidirecional (do not have bi-directional shaft rota-

tion). Refer to "Pump Rotation" on page 2.

PV4018-2928

123456

Summary of Contents for PF500-10

Page 1: ...each piston pumping chamber to direct flow from the inlet side of the pump to the pump outlet port During operation a fixed angle wobble plate rotates with the drive shaft The angled surface imparts...

Page 2: ...or beyond the optimum fluid viscosity range IMPORTANT Refer to Fluid Recommendations below Port Fitting Configurations 1 Dynex pumps are available with outlet ports suitable for use at various pressur...

Page 3: ...ck for correct circuit connections and leaks 4 Then run the pump at no load pressure all valves in an open neutral position for several minutes Check to be sure the pump does not leak or develop exces...

Page 4: ...resulting in fluid contamination it is important to drain and clean the reservoir all lines filter screens and all components Refill the system with new fluid This must be done to prevent immediate f...

Page 5: ...e that air is bled from pump case and inlet lines System Not Developing Pressure 1 Check possible causes listed above for Low Flow or No Pump Flow 2 Check the relief valve and any pres sure control va...

Page 6: ...0 0 0 0 PF4308 0 0 0 0 5 0 4 PF4309 0 0 5 0 4 10 0 7 PF4310 and PF4312 0 0 5 0 4 15 1 0 Variable Delivery Pumps PV4018 and PV4026 0 0 5 0 4 5 0 4 10 0 7 PV4033 0 0 5 0 4 5 0 4 PV6054 0 0 5 0 4 5 0 4...

Page 7: ...UMP COVER O RING COUPLING Typical S A E Straight Thread port connection Typical British Standard Pipe parallel fitting with shoulder port connection PUMP COVER COUPLING SEAL RING SHOULDER O RING PUMP...

Page 8: ...gdom Tel 44 0 1480 213980 FAX 44 0 1480 405662 E mail sales dynexhydraulics co uk USA Headquarters Dynex Rivett Inc 770 Capitol Drive Pewaukee WI 53072 U S A Tel 262 691 2222 FAX 262 691 0312 E mail s...

Reviews: